For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 19-56 — Alternative materials, design and methods of construction and equipment

Code of Ordinances, City of Boca Raton, Florida (Supp. 72 Update 2: codified through Ordinance of June 9, 2026 (online updated October 20, 2026)) · Boca Raton Code of Ordinances § 19-56

Corpus is an independent public-information project, not the official City of Boca Raton website. Stable reference: corpuslaw.us/code/6ed3a61f-89bf-4252-a76a-55a6e09238c5

Sec. 19-56. - Alternative materials, design and methods of construction and equipment.

(1) The provisions of this building code are not intended to prevent the installation of any material or to prohibit any design or method of construction not specifically prescribed by this building code, provided that any such alternative has been approved. An alternative material, design or method of construction shall be approved where the building official finds that the proposed design is satisfactory and complies with the intent of the provisions of this building code, and that the material, method or work offered is, for the purpose intended, at least the equivalent of that prescribed in this building code in quality, strength, effectiveness, fire resistance, durability and safety. When alternate life safety systems are designed, the SFPE Engineering Guide to Performance-Based Fire Protection Analysis and Design of Buildings, or other methods approved by the building official may be used. The building official shall require that sufficient evidence or proof be submitted to substantiate any claim made regarding the alternative. (2) Research reports and supporting data, where necessary to assist in the approval of materials or assemblies not specifically provided for in this building code, shall consist of valid research reports from sources approved by the building official and be provided at the applicant's expense. (3) Whenever there is insufficient evidence of compliance with the provisions of this building code, or evidence that a material or method does not conform to the requirements of this building code, or in order to substantiate claims for alternative materials or methods, the building official shall have the authority to require tests as evidence of compliance to be made by the applicant at his sole cost and expense and at no expense to the city. Test methods shall be as specified in this building code or by other recognized test standards. In the absence of recognized and accepted test methods, the building official shall approve the testing procedures. Tests shall be performed by an agency approved by the building official. Reports of such tests shall be retained by the building official for the period required for retention of public records. (4) Alternative designs and technologies for providing access to and usability of a facility for persons with disabilities shall be in accordance with provisions of the Florida Building Code, Accessibility.

(Ord. No. 5455, § 2, 5-22-18)

Ask a question about Boca Raton law

Corpus searches the Boca Raton sections it holds and shows the ones that match, with their citations. Free, no sign-in.