Sec. 21-169. - Anchoring.
All new manufactured homes and replacement manufactured homes shall be installed using methods and practices which minimize flood damage and shall be securely anchored to an adequately anchored foundation system to resist flotation, collapse or lateral movement. Methods of anchoring may include use of over-the-top or frame ties to ground anchors. This anchoring requirement is in addition to applicable state and local anchoring requirements for wind resistance. Specific requirements shall include the following: (1) Over-the-top ties shall be provided at each end of the manufactured home, with 1 additional tie per side at an intermediate location on manufactured homes of less than 50 feet, or 2 additional ties per side for manufactured homes of 50 feet or more; (2) Frame ties shall be provided at each corner of the home, with 4 additional ties per side at intermediate points for manufactured homes less than 50 feet long, or additional ties for manufactured homes of 50 feet or longer; (3) All components of the anchoring systems shall be capable of carrying a force of 4,800 pounds; and (4) Any additions to the manufactured home shall be similarly anchored.
(Ord. No. 5418, § 2, 10-10-17)