§ 21-68 — Additional analyses and certifications
Code of Ordinances, City of Boca Raton, Florida (Supp. 72 Update 2: codified through Ordinance of June 9, 2026 (online updated October 20, 2026)) · Boca Raton Code of Ordinances § 21-68
Corpus is an independent public-information project, not the official City of Boca Raton website. Stable reference: corpuslaw.us/code/a175d35a-d16b-4345-969d-db846809c74b
Sec. 21-68. - Additional analyses and certifications.
As applicable to the location and nature of the proposed development activity, and in addition to the requirements of this section, the applicant shall have the following analyses signed and sealed by a state licensed engineer for submission with the site plan and construction documents: (1) For development activities proposed to be located in a floodway, either: (i) a floodway encroachment analysis demonstrating that the encroachment of the proposed development will not cause any increase in base flood elevations, or (ii) Where the applicant proposes to undertake development activities that do increase base flood elevations, the applicant shall submit a floodway encroachment analysis to FEMA as specified in section 21-69, and shall submit the conditional letter of map revision, if issued by FEMA, with the site plan and construction documents. (2) For development activities proposed to be located in a riverine flood hazard area for which base flood elevations are included in the flood insurance study or on the FIRM, and floodways have not been designated, hydrologic and hydraulic analyses that demonstrate that the cumulative effect of the proposed development, when combined with all other existing and anticipated flood hazard area encroachments, will not increase the base flood elevation more than 1 foot at any point within the community. This requirement does not apply in isolated flood hazard areas not connected to a riverine flood hazard area or in flood hazard areas identified as Zone AO or Zone AH. (3) For alteration of a watercourse, an engineering analysis prepared in accordance with standard engineering practices shall demonstrates that the flood-carrying capacity of the altered or relocated portion of the watercourse will not be decreased, and certification shall be provided that the altered watercourse will be maintained in a manner which preserves the channel's flood-carrying capacity. The applicant shall submit the analysis to FEMA as specified in section 21-69 of this chapter. (4) For activities that propose to alter sand dunes or mangrove stands in coastal high hazard areas (zone V), an engineering analysis shall demonstrates that the proposed alteration will not increase the potential for flood damage.
(Ord. No. 5418, § 2, 10-10-17; Ord. No. 5720, § 2, 12-10-24)
Ask a question about Boca Raton law
Corpus searches the Boca Raton sections it holds and shows the ones that match, with their citations. Free, no sign-in.