§ 23-190 — Driveways and off-street parking facilities (excluding single-family and duplex residential plots)
Code of Ordinances, City of Boca Raton, Florida (Supp. 72 Update 2: codified through Ordinance of June 9, 2026 (online updated October 20, 2026)) · Boca Raton Code of Ordinances § 23-190
Corpus is an independent public-information project, not the official City of Boca Raton website. Stable reference: corpuslaw.us/code/296189e4-505f-4114-b78c-3930c866b031
Sec. 23-190. - Driveways and off-street parking facilities (excluding single-family and duplex residential plots).
The design of driveways and off-street parking facilities serving any building or use (excluding single-family and duplex residential plots regulated by section 23-189) shall be regulated as follows. (a) Minimum driveway width (1-way). Any plot with driveway access to a street shall have a minimum 14-foot-wide driveway for 1-way ingress or egress. Driveways shall permit traffic to enter and leave the plot simultaneously without conflict in aisles, parking or maneuvering areas. (b) Maneuvering. The area within the plot to which a driveway provides access shall be of sufficient size to allow all necessary functions for loading, unloading and parking maneuvers to be carried out on the plot and completely off the street right-of-way. No parking row shall exceed 250 feet in length except where a parking row is contiguous to and parallel with the building or property lines. (c) Header curbs. All driveways shall be provided with flush concrete header curbs along the driveway radii for driveway connections to uncurbed roadways. (d) Driveway classification. Each driveway shall be classified as urban or suburban and regulated accordingly: 1. Urban driveway. Any driveway located in the downtown area, within a VC district, or at points of access to a VC district is an urban driveway. The urban driveways shall be designed in accordance with the minimum standards outlined in Table 23A: Table 23A. Urban Driveway Standards Driveway Type | Maximum Volume (vehicles/ hour) | Driveway Width | Reservoir (feet) | Radius Return (feet) Arterial | Collector | Local Minor | 150 | 12' ingress, 12' egress | 25 | 25 | 20 | 15 Intermediate | 300 | 12' ingress, two 11' egress | 25 | 25 | 20 | 15 Major | 500 | 14' ingress, 4' median, two 11' egress | 50 | 30 | 25 | 20 2. Suburban driveway. Any driveway providing service for a parcel located outside the downtown area is a suburban driveway. Suburban driveways shall be designed in accordance with the minimum standards outlined in Table 23B. Table 23B. Suburban Driveway Standards Driveway Type | Maximum Volume (vehicles/ hour) | Driveway Width | Reservoir (feet) | Radius Return (feet) Arterial | Collector | Local Minor | 50 | 12' ingress, 12' egress | 25 | 30 | 20 | 15 Intermediate | 200 | 14' ingress, 4' median, two 12' egress | 50 | 30 | 20 | 15 Major | 500 | 14' ingress, 4' median, two 12' egress | 100 | 35 | 30 | 20 3. Driveway type. Tables 23A and 23B outline the characteristics of minor, intermediate, and major urban and suburban driveways. The driveway type is determined by the maximum driveway volume occurring within one hour. 4. Roadway class. The roadway class (arterial, collector or local) referenced in Tables 23A and 23B shall be defined by the roadway classification map, as set forth in the engineering design standards manual. 5. Flared turnouts. Minor driveways located on curbed local streets or curbed collectors may design flared turnout driveways. The driveway flare shall be equivalent to the radius returns noted in Tables 23A and 23B. 6. High driveway volumes. Driveways with volumes greater than 500 vehicles per hour shall be designed using intersection design standards as set forth in the engineering design standards manual. 7. Driveways located on a divided roadway. Where left-turn egress is not allowed, dual egress lanes are not required. 8. Driveways with right-turn lanes. The ingress radius return may be designed using the next, lower roadway class located in the Tables 23A and 23B, if an ingress right-turn lane is provided. 9. Minimum driveway design standards. The minimum driveway design standards are set forth in Tables 23A and 23B. The city's traffic engineer, fire chief or the fire chief's designee may require that the driveway design exceed the minimum standards based on the characteristics of the land use, safety, traffic analyses or accepted traffic engineering practices. (e) Driveway signalization. Any driveway requiring a traffic signal shall conform to those warrants specified in the Manual on Uniform Traffic Control Devices, United States Department of Transportation, Federal Highway Administration, 2000, as it may be amended. The manual is adopted by reference, and a copy shall be maintained for public inspection in the office of the development services department. The installation of any traffic signal under the jurisdiction or maintenance responsibility of the city shall be subject to the accepted standards and approval of the city's traffic engineer. (f) Ingress lanes. 1. For any development, a turn lane with appropriate storage and transition shall be provided at each driveway where the peak hour turn volume exceeds the threshold set forth in Table 23C. The turn lane design shall comply with the standards of the jurisdiction, which maintains the road. Turn lane design on city and private roads shall comply with the "Manual of Uniform Minimum Standards for Design, Construction, and Maintenance for Streets and Highways" (commonly known as the "Florida Greenbook"), as it may be amended from time to time. Construction of turn lanes shall include, but not be limited to, turn lane pavement, sub-base, stabilization, curbing, drainage and utility relocation. Table 23C. Volume Requirement for Ingress Turn Lane Ingress Lane | Collector or Arterial Speed Limit 40 mph and Higher | Less than 40 mph Left-turn lane | Greater than 30 vehicles/hour | Greater than 60 vehicles/hour Right-turn lane | Greater than 40 vehicles/hour | Greater than 80 vehicles/hour 2. Ingress turn lanes on local roads. Ingress turn lanes may be required on local roads at the recommendation of the city's traffic engineer to the planning and zoning board, the city council or the community redevelopment agency. The city's traffic engineer may require the applicant to submit an engineering study to identify the need for turn lanes on local roads. 3. Where this chapter requires a separate right-turn lane and the turn lane cannot be provided due to right-of-way or environmental constraints, a 35 to 50 foot driveway radius return shall be provided on the approach edge of the driveway as determined by the city's traffic engineer. (g) Required improvements to intersections impacted by development. Improvements to an intersection shall be required to be constructed by the developer of any plot where the development causes the intersection to be impacted by traffic generated as a result of the development. Intersection improvements shall be included as a condition of approval by the planning and zoning board, city council or community redevelopment agency. (h) Off-street vehicular circulation. An off-street facility shall have full internal vehicular circulation and storage. Vehicle circulation shall be completely contained within the facility, and vehicles located within 1 portion of the facility shall have access to all other portions without using the adjacent street system. (i) Off-street truck maneuvering. Where the use of a plot includes a truck loading, unloading, parking or service facility, adequate space shall be provided such that all truck maneuvering is performed off the street. (j) Off-street vehicle reservoir areas. Adequate reservoir capacity shall be required for both inbound and outbound vehicles to facilitate the safe and efficient movement between the street and the parking facility. An inbound reservoir shall be of sufficient size to ensure that vehicles will not obstruct the street, sidewalk and/or circulation adjacent to the facility. An outbound reservoir shall be required to eliminate backup and delay of vehicles within the facility. Where a gated entry is proposed for any development, the inbound reservoir distance shall be of sufficient length to store all arriving vehicles projected at peak times. Where a gated entry is proposed for a non-residential development, a queuing study, subject to approval by the city traffic engineer, shall be submitted to determine the required inbound reservoir length. Where a gated entry is proposed for a residential development, 2 ingress lanes and a turnaround in advance of the gate shall be provided, and Table 23D outlines the requirements for the inbound reservoir length. Table 23D. Gated Residential Development - Inbound Reservoir Length Number of Dwelling Units | Required Storage from Call Box to Property Line Local Road | Collector and Arterial ≤ 10 | 25 feet | 50 feet ≤ 50 | 50 feet | 50 feet ≤ 100 | 75 feet | 75 feet ≤ 125 | 100 feet | 100 feet > 125 | Based upon a queuing study, subject to approval by the city traffic engineer to determine the required inbound reservoir length In addition, where 2 or more gated entries are proposed for a residential development, the required inbound reservoir length for each gated entry shall be determined as follows: (i) the percentage of entering vehicles at peak times shall be projected at each gated entry by an analysis submitted by the applicant, subject to approval by the city traffic engineer; (ii) the percentage of entering vehicles at peak times for each gated entry shall be multiplied by the total number of dwelling units in the residential development to determine the number of dwelling units assigned to each gate; and, (iii) the required inbound reservoir length for each gated entry shall be as set forth in Table 23D, based on the number of dwelling units determined in (ii). (k) Special considerations and exceptions. In the case of special driveway needs such as service stations, drive-in banks or other high-volume traffic uses, or where property is of a nature that the requirements of this Code cannot be met, an applicant may request a technical deviation from these requirements, which application shall be processed in accordance with the procedures and requirements set forth in section 28-9, and which request shall be based upon a detailed traffic engineering study. 1. A traffic engineering study shall be performed and certified by a professional engineer qualified in traffic engineering. The study shall demonstrate how the technical deviation meets each of the following standards. The planning and zoning board, the city council, or the community redevelopment agency, as appropriate, shall deny any application that does not meet the following standards: a. The technical deviation will not diminish the site's vehicular or pedestrian operation. If applicable, operational analyses shall be performed. b. The technical deviation results in preferable environmental impacts or traffic circulation design. c. The technical deviation is the minimum deviation necessary for the petitioner to make reasonable use of the property. d. The technical deviation is not detrimental to the public welfare, or injurious to property or improvements in the surrounding area or neighborhood. e. Special and unique conditions exist, which are not directly attributable to the actions of the applicant. 2. Notice of the public hearing shall be provided as set forth in section 28-8. 3. Based upon the study and a determination by the planning and zoning board, the city council, or the community redevelopment agency, as appropriate, after public hearing that the alternative design will meet the standards set forth in this section, the alternate design may be approved. 4. In granting a technical deviation, the planning and zoning board, city council, or community redevelopment agency, as appropriate, may prescribe conditions deemed necessary to protect the public interest and to ensure compliance with applicable codes and the comprehensive plan. 5. Where an application for a technical deviation pursuant to this section has been approved concurrently with an application for a site plan approval, conditional use approval, or other development order, the technical deviation shall expire at the same time as such development order; provided, however, such technical deviation may be extended concurrently with, and in the same manner as, such development order. Where an application for technical deviation has not been processed concurrently with an application for any development order, the planning and zoning board shall act upon the application, and the expiration and extension of any technical deviation shall be governed by section 28-58. 6. The decision of the planning and zoning board may be appealed to the city council, which appeal shall be processed in accordance with the procedures and requirements set forth in section 28-10. (l) Administration. All applications for such permits shall be made to the development services department, which shall have the authority to grant the same in conformity with the provisions of this section. (m) Application to existing driveways and off-street parking facilities: 1. Any driveway or off-street parking facility existing on June 24, 1980, and which by the terms of this section has become a nonconforming driveway or off-street parking facility is hereby declared not to be in violation of this section, subject to the conditions following herein. 2. In the event of an expansion of an existing use for which a nonconforming driveway and off-street parking facility has been constructed, the provisions of this section shall apply; and the expanded use shall make necessary compliance with the terms and conditions of this section. 3. If an existing driveway or off-street parking facility can be brought into conformance with the requirements of this section by minor alterations to the site, then, if a change on the site is made which necessitates the issuance of a building permit, the adjustments and alterations shall be made on the site to conform with the provisions of this section.
(Code 1966, § 7-65(4)(a)—(d), (f)—(r); Ord. No. 4122, § 26, 9-28-93; Ord. No. 4170, § 27, 9-27-94; Ord. No. 4674, § 3, 12-10-02; Ord. No. 4908, § 3, 2-28-06; Ord. No. 5450, § 1, 4-10-18; Ord. No. 5600, § 9, 10-26-21; Ord. No. 5642, § 9, 1-10-23)
Ask a question about Boca Raton law
Corpus searches the Boca Raton sections it holds and shows the ones that match, with their citations. Free, no sign-in.
