Sec. 28-1249. - Design and performance standards.

(1) Limitation on retail floor area. (a) The maximum floor area for any individual retail establishment is 40,000 square feet. (b) The 3 individual retail establishments with the largest floor areas shall not have a combined floor area of more than 80,000 square feet, collectively. (2) Limitation on ground floor residential area. (a) For developments in which retail and/or office uses comprise more than five percent of the total floor area, no more than 70 percent of the ground floor area shall be used for multiple-family dwellings (including townhomes); and (b) Dwelling units shall not be located on the ground floor of mixed-use buildings. (3) Townhomes. (a) Townhomes shall be designed and developed such that no more than 2 adjacent townhomes are substantially alike in terms of either façade, materials, color, or roof. (b) Townhomes shall be developed in groups of no less than 3 and no more than 8 units that are attached by common walls. (4) Design of structured parking. Structured parking shall be designed and configured so that parking structures are not a material part of the physical character of the District, as follows: (a) Structured parking shall not have vehicular access points on any primary street within the VC district, Federal Highway, or Dixie Highway; (b) Structured parking should not be designed with more than one dead-end aisle; and (c) Structured parking shall be screened as follows: 1. Intervening buildings or "wraps" composed of permitted uses other than parking shall screen ground-level views of parking structures form primary streets within the VC district and from public streets outside of the VC district. In addition or in the alternative, permitted uses other than parking may be located in the ground level of parking structures to disguise their use as parking. 2. Any sides of a parking structure that are exposed to secondary, residential, or service streets shall be designed so that use of the structure for parking is not obvious except at points of ingress and egress. (5) Location and design of off-street surface parking lots. (a) Surface parking spaces shall be located to the rear and sides of buildings wherever feasible. No off-street surface parking lots shall be located between the front façade of any building(s) and the primary adjacent street. (b) Surface parking lots and maneuvering areas shall not be located between a primary building's entrance and an abutting urban minor arterial or urban collector street, except where the applicant has demonstrated that no other alternative is available. (c) Surface parking lots and maneuvering areas located to the side of a building cannot occupy more than 50 percent of a site's frontage onto an urban minor arterial or urban collector street. (d) Wherever possible, parking lots and maneuvering areas on corner lots should not be located adjacent to intersections. (e) Provide smaller, more dispersed surface parking lots instead of one large parking area. (6) Design of pedestrian connections. In addition to the requirements set forth in section 23-162, sidewalk policy, the following requirements shall be met: (a) Covered pedestrian access shall be provided between parking structures and the front of the principal adjacent buildings that they are intended to serve. (b) A sidewalk shall be provided immediately adjacent to the exterior wall of a new building that is greater than 100 feet in length when the wall is located next to an off-street surface parking lot or street. A pedestrian path shall also be provided along the entire length of a wall that includes a principal public entrance to the building. Notwithstanding the previous sentence, a pedestrian path need not be provided if: 1. The edge of the building is within 20 feet of 1 or more sidewalks and two or more building entrances are connected to the sidewalks by an on-site pedestrian route, or 2. The edge of the building is bordered by a perimeter of landscaping that does not exceed 30 feet in width and an onsite pedestrian route is constructed at the outside edge of the landscaped area. (c) If there is insufficient right-of-way to accommodate the minimum sidewalk and buffer widths for Federal Highway set out in section 23-162, new developments shall either dedicate public rights of way or provide easements for bicycles and pedestrians to the extent necessary to provide the required widths. (d) Pedestrian access points outside of the public rights-of-way to adjacent lots shall be provided to facilitate pedestrian circulation between developments. (e) All on-site pedestrian walkways located in vehicle use areas shall be distinguished from driving surfaces to enhance pedestrian safety and comfort.

(Ord. No. 4908, § 1, 2-28-06; Ord. No. 5169, § 1, 6-7-11)

Ask a question about Boca Raton law

Corpus searches the Boca Raton sections it holds and shows the ones that match, with their citations. Free, no sign-in.