§ 7-37 — Fire flow requirements
Code of Ordinances, City of Boca Raton, Florida (Supp. 72 Update 2: codified through Ordinance of June 9, 2026 (online updated October 20, 2026)) · Boca Raton Code of Ordinances § 7-37
Corpus is an independent public-information project, not the official City of Boca Raton website. Stable reference: corpuslaw.us/code/a1a60929-8dd6-474c-8e24-54d0da826634
Sec. 7-37. - Fire flow requirements.
(1) These requirements are to ensure that an adequate water supply for fire suppression exists by establishing minimum flow rates required to control and extinguish fires that may occur within prescribed occupancy classifications. The requirements of this section shall be applicable to public and private water systems, including individual properties and land development projects. (2) Required fire flow. (a) For purposes of this subsection, the "required fire flow" means the rate of flow needed for firefighting purposes to confine a major fire to the buildings within a block or other contiguous grouping. The determination of the required fire flow depends upon the size, construction, occupancy, and exposure of buildings within the surrounding block or group of buildings, and the presence of automatic sprinkler protection. This determination shall be made by the fire chief or his/her designee, in accordance with the criteria established by this section and requirements of the Guide for Determination of Needed Fire Flow, published by the Insurance Services Office, ISO Edition 08-2005, and as it may from time to time be amended. (b) The minimum required fire flow for each zoning classification shall be in accordance with Table I located at the end of this section. Where conditions indicate that consideration must be given to possible simultaneous fires, as determined by the fire chief utilizing the criteria established or adopted herein, additional gallons per minute of fire flow shall be required. However, the maximum required fire flow for any system shall be 12,000 gallons per minute. The required minimum duration for fire flow is listed in Table II at the end of this section. All required fire flow rates shall be in addition to the water flow rates necessary for normal flow demands. (3) Flow demands. Flow demands for design systems shall be calculated based on the fire flow requirement for the project. The calculations shall be in accordance with the FFPC. The average daily flow for domestic use shall be calculated pursuant to normal flow demand criteria as detailed in the city utilities services department standards manual. (4) Fire hydrants and fire flow requirements; exemptions and qualifications; interim criteria. (a) All new buildings, and all existing buildings being altered to increase the area, height, or occupancy, shall have the required number of fire hydrants as specified in Table III located at the end of this section. Each fire hydrant shall be connected to a public water supply which meets the fire flow requirements specified in Tables I and II, except as follows: 1. All duplex and single-family detached homes not requiring water main extensions for domestic purposes. shall be exempt from this requirement. (For purposes of this subsection, "water main extension" shall mean the extension of a water supply system by installation and construction of a new water main, 6 inches in diameter or larger, as required by the public utility.) 2. Additions to existing buildings and accessory buildings not exceeding 25% of the square footage of existing structure, but in no event greater than 5,000 square feet, shall be exempt from this requirement. 3. Neighborhood shopping centers with buildings totaling an area of less than 100,000 square feet with no building under 1 roof of more than 10,000 square feet, with no building exceeding 2 stories in height, and with at least 25-foot separations between buildings, shall meet fire flow requirements of at least 1,250 gallons per minute. 4. Individual industrial or commercial buildings or structures not part of a neighborhood shopping center or industrial park, less than 5,000 square feet in area, and with low or ordinary hazard content shall meet a fire flow requirement of at least 750 gallons per minute. (b) If the rate of fire flow required under the terms of this section is not available from the public utility at the time of application for a building permit, and none of the exemptions or qualifications in (a)1—4 above apply, then the following interim criteria shall govern the issuance of building permits: 1. Properties classified as having low hazard contents, and not exceeding 2 stories in height, will be required to provide a minimum of 50% of the flow rate described in Table I for its zoning district that is set out at the end of this section. 2. Properties classified as having ordinary hazard contents, and not exceeding 2 stories in height, will be required to provide a minimum of 70% of the flow rate described in Table I for its zoning district that is set out at the end of this section. 3. Properties classified as having low or ordinary hazard contents, and having more than 2 stories but not exceeding 5 stories in height, will be required to provide a minimum of 75% of the flow rate described in Table I for its zoning district that is set out at the end of this section. 4. Properties classified as having high hazard contents will be required to provide 100% of the flow rate described in Table I for its zoning district that is set out at the end of this section. 5. All properties in excess of 5 stories in height will be required to provide 100% of the flow rate described in Table I for its zoning district that is set out at the end of this section. 6. "Low hazard contents," "ordinary hazard contents" and "high hazard contents" are defined in the FFPC. 7. In all cases of new construction where less than the flow rate described in Table I is permitted pursuant to the provisions of subsection (4) above, engineering and construction of new facilities to meet the total fire flow requirements as described in Table I will be provided so that at the time the public utility is capable of providing full fire flow, the properties receiving the flow will be capable of utilizing the full fire flow provided by the utility. 8. In all cases wherein the interim criteria in subsection (4) above is utilized, no less than a 500-gallon-per-minute fire flow shall be permitted for any type of improved property, and all fire flow tests will be calculated with a minimum of 20 psi residual pressure remaining in the water main. (5) Supplemental flow systems. If the minimum fire flow requirements set out in this section cannot be met by the water supply utility, then supplemental flows through an on-site, or readily available, system that meets the minimum fire flow requirements of this section and meets with the requirements of the fire rescue services department must be provided. (6) Extensions of time; bond. If the required fire flow is not available to allow the issuance of a certificate of occupancy, but it is determined by the fire rescue services department that system improvements are in process and are imminent so that the fire flow requirements will be satisfied, then the fire rescue services department may extend the time to meet the requirements of this section for an interim period not to exceed 90 days and may authorize a temporary certificate of occupancy based thereon. A bond sufficient to assure completion of the required system improvements in order to meet the fire flow requirements shall be posted with the city manager. The amount of the bond shall be determined by the fire rescue services department and shall be equivalent to 200% of the cost to complete the fire flow improvements. (7) Fire hydrants and fire hydrant branches. (a) The location, number and sizes of the fire hydrants, and the fire hydrant branches, shall be designated by the fire rescue services department in accordance with Table III. (b) Fire hydrants of the approved municipal design and system pattern shall be provided along all primary roadways and fire lanes throughout any proposed project. When such development fronts on 1 or more existing public street(s), fire hydrants shall be located along the public street(s) as well as throughout the entire project. Spacing shall be measured along the actual route that the fire apparatus will travel. (c) Unobstructed access to fire hydrants and to on-site private systems shall be provided and maintained to accommodate firefighting apparatus. (8) Distribution systems. The supply mains shall be of adequate size and have properly arranged connections to the arterial mains, which shall extend throughout the system and have numerous connections to the secondary feeders that supply the minor distribution. (9) Main sizes. Main sizes and system patterns shall be subject to approval of all applicable departments pursuant to fire and normal flow demand criteria. Design standards shall be in conformance with current editions of the city utilities services department standards manual. (10) Pressure. Sufficient pressures shall be provided within the system to maintain 20 pounds per square inch ("psi") residual pressure while providing required fire flows. In those cases where system supply design and hydrant locations are capable of meeting full domestic, commercial and fire flow demands, residual pressures of 10 psi will be permitted. (11) Violations. It shall be a violation for any person or entity to: (a) Use or operate any fire hydrant or any other valve on a fire system that is intended for use by the city, unless a fire hydrant use permit has been issued by the city to such person or entity and such person or entity complies with all appropriate provisions of chapter 17, Code of Ordinances. (b) Remove, tamper with, or otherwise disturb any fire hydrant or firefighting appliance except for the purpose of extinguishing fires, firefighting training or making necessary repairs, without first obtaining written approval of the city. TABLE I. REQUIRED FIRE FLOWS BY ZONING CLASSIFICATION Zoning Districts | Requirement Group 1: R-1-F, R-1-G, AR, RS, | The system shall deliver not less than 500 gallons per minute at 20 psi residual on the system. Each fire hydrant shall deliver not less than 500 gallons per minute. Group 2: R-1-A, R-1-B, R-1-C, R-1-D, R-1-E, NCBD, PUD, RE1, RE2 | The system shall deliver not less than 1,000 gallons per minute at 20 psi residual on the system. Each fire hydrant shall deliver not less than 750 gallons per minute. Group 3: R-2, R-3, B-1, RM | The system shall deliver not less than 1,500 gallons per minute at 20 psi residual on the system. Each fire hydrant shall deliver not less than 750 gallons per minute. Group 4: R-B-1, R-3-A, R-3-B, R-3-C, R-4, B-2, B-3, B-4, C-1, LIRP, M-1, MC, REC, PT, PL, CG, CN, CS, AG | The system shall deliver not less than 2,000 gallons per minute at 20 psi residual on the system. Each fire hydrant shall deliver not less than 750 gallons per minute. Group 5: R-3-D, R-3-E, R-3-F, R-5, R-5-A, M-2, M-3, W-I, POI, LB, PUD, PCD, PID, IG/S1, DDRI, SE, RID/DDRI, VC, LIRP-5, PM0.25 | The system shall deliver not less than 3,000 gallons per minute at 20 psi residual on the system. Each fire hydrant shall deliver not less than 1,000 gallons per minute. TABLE II. REQUIRED DURATION FOR FIRE FLOW Required Fire Flow (gallons per minute) | Required Duration (hours) 10,000 and greater | 10 9,500 | 9 9,000 | 9 8,500 | 8 8,000 | 8 7,500 | 7 7,000 | 7 6,500 | 6 6,000 | 6 5,500 | 5 5,000 | 5 4,500 | 4 4,000 | 4 3,500 | 3 3,000 | 3 2,500 and less | 2 TABLE III. FIRE HYDRANT SPACING Districts | Hydrant Spacing (feet) 1 | Multifamily structures 2 or more stories in height | 300 2 | Commercial, industrial, and similar structures regardless of height | 300 3 | Areas with multi-laned, divided highways (hydrants shall be provided along both sides of such roads with the location of curb cuts and median cuts considered) | 400 4 | Residential districts, single-family and duplex areas with dead-end streets | 500 5 | Residential districts, single-family and duplex areas with complete internal circulation | 600 6 | Residential districts, cluster developments 1 story in height | 400
(Ord. No. 5726, § 2, 2-25-25)
Ask a question about Boca Raton law
Corpus searches the Boca Raton sections it holds and shows the ones that match, with their citations. Free, no sign-in.
