§ 7-60 — Automatic fire-extinguishing and detection systems

Code of Ordinances, City of Boca Raton, Florida (Supp. 72 Update 2: codified through Ordinance of June 9, 2026 (online updated October 20, 2026)) · Boca Raton Code of Ordinances § 7-60

Corpus is an independent public-information project, not the official City of Boca Raton website. Stable reference: corpuslaw.us/code/cd854226-373f-4c77-a6a7-bef9501a6358

Sec. 7-60. - Automatic fire-extinguishing and detection systems.

In addition to complying with the Florida Fire Prevention Code, the Florida Building Code, and the state fire marshal's rules and regulations, any automatic or manual fire alarm signal system, automatic fire-extinguishing, or automatic fire detection system hereafter installed, shall be listed by a Nationally Recognized Testing Laboratory ("NRTL") approved in accordance with the provisions of F.S. § 633.334, and shall conform to the following requirements: (1) Any fire alarm system, automatic fire sprinkler system, smoke, ionization or heat detection system, clean agent extinguishing system, automatic fire-extinguishing devices, (except standalone automatic extinguishing systems in hoods and ducts), installed in any occupancy, which may be required by provisions of the applicable code, shall be so arranged that the normal operation of any required alarm-initiating device or the operation of any automatic fire-extinguishing system shall automatically transmit an alarm to a NRTL central station inspected and approved by the fire rescue services department. The fire rescue services department shall maintain a listing of all approved NRTL central station companies. (2) A NRTL central station, in accordance with NFPA 72 (2010) section 10.4, shall be identified by the NRTL certificated service provider on the NRTL certificate for all newly installed and required fire alarm systems. An existing required fire alarm system that is having the control panel or alarm components replaced shall be considered a new fire alarm system for the purposes of this section. Such systems shall meet the certificating requirements of the applicable codes. NRTL listed central station service, in full compliance with NFPA 72, shall be maintained, so long as the requirement for the fire alarm system exists. (3) All fire alarm signal systems and automatic extinguishing and detection systems, installed in accordance with this section, shall be maintained under a written service contract providing for regular maintenance and testing of the system in accordance with the state fire marshal's rules and regulations. When the fire rescue services department determines that a fire alarm system is out of service, in need of repair, or if verification is needed to confirm that the fire alarm system is working properly, the property owner shall have an alarm technician respond as required in NFPA 72. (4) The service company performing the maintenance and tests shall forward a written report to the fire rescue services department indicating the nature of any deficiencies, impairments, repairs, modifications, and/or corrections that were completed by the service company, the date and time of such tests and inspections, and any other information, which may be required by the fire rescue services department. A copy of all issued service reports must be maintained by the owner of the property for the lifetime of the building's fire protection systems. An additional copy must remain on the property's premises in the fire command room or fire protection closet for the lifetime of the building's fire alarm protection systems and shall be available for inspection by the fire rescue services department at any time. All reports related to fire protection system inspections, maintenance, and testing, shall be reported to the fire rescue services department, through the city's fire inspection reporting system. (5) In accordance with NFPA 72, all fire alarm signal systems, automatic extinguishing and/or detection systems, shall be provided with an approved annunciator panel. Annunciator panels, either remote or part of the building's main fire alarm control panel, shall be equipped with an LCD display with a minimum 80-character capability. Each annunciator panel shall be designed or programmed to indicate the floor number, the section of the building reporting a fire alarm, and the fire condition. Each alarm-initiating device shall indicate a specific location on such annunciator. Each alarm initiating device shall also indicate its specific location to the monitoring central station. The annunciator shall respond to either manual or automatic devices, and all devices within the system shall be connected to the annunciator. The location of the annunciator panel shall be designated by the fire rescue services department. Fire alarm systems that are installed solely for the purpose of monitoring a fire sprinkler system shall be permitted upon the approval of the fire chief or his/her designee. In a complex with multiple buildings, each building shall have its own annunciator panel that reports to the main fire alarm panel located in the fire protection closet or FACP room. All alarm, supervisory, and trouble signals must be transmitted to a central station monitoring company. Fire alarms in a high-rise building (a building that is greater than 75 feet in height where the building height is measured from the lowest level of fire rescue services department access to the floor of the highest occupiable level) shall be programmed to put the fire alarm system into an alarm condition on the floor of an incident, one floor below the incident, and all floors above the incident floor in order to provide an alert. (6) Carbon monoxide detection systems shall be installed in new buildings as required by the FFPC, NFPA 720, and NFPA 72. Carbon monoxide detection systems shall be installed in new parking structures as required in NFPA 88A. Such installed carbon monoxide detection devices shall be programmed to provide a supervisory signal to the fire alarm panel and any area attended by security or staff at a level of 99 parts per million. Further, such carbon monoxide detection devices that detect a carbon monoxide level that exceeds 199 parts per million shall be programmed to send an alarm signal to the fire alarm panel activating notification devices alerting all occupants of the building to evacuate the building. Existing parking structures will be required to comply with this Code if a level 2 or level 3 alteration is conducted as defined by the Florida Building Code. (7) All fire alarm signal and detection systems shall be provided with a secondary source of power always available for use in the event of failure of the primary power supply to ensure continuous operation of the system, pursuant to the requirements of NFPA 72. (8) Pre-signal fire alarm systems shall not be permitted. (9) A change in service provider or a transmitter requires a permit. Once a permit is acquired, the fire rescue services department shall conduct a test to verify that the alarm system is reporting the appropriate signals to the central station as required by code. (10) Communications methods shall comply with the requirements of NFPA 72 and shall be approved by the Fire Chief or designee. (11) Rooms or areas where carbon dioxide (CO2) storage vessel(s) are located or, in an enclosed area, or in a below grade outdoor location, shall be provided with gas detection and an alarm system for general area monitoring as provided in NFPA 55.

(Ord. No. 5726, § 2, 2-25-25)

Ask a question about Boca Raton law

Corpus searches the Boca Raton sections it holds and shows the ones that match, with their citations. Free, no sign-in.