For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 10-59 — Mechanical and electrical requirements

Code of Ordinances of the City of Boynton Beach, Florida (Codified through Ordinance No. 26-023, enacted July 7, 2026. (Supp. No. 2)) · Boynton Beach Code of Ordinances § 10-59

Corpus is an independent public-information project, not the official City of Boynton Beach website. Stable reference: corpuslaw.us/code/5bbbdeee-1df8-41e0-ba7f-63b3be345fe3

Sec. 10-59. - Mechanical and electrical requirements.

(a) General. (1) Scope. The provisions of this section shall govern the minimum mechanical and electrical facilities and equipment to be provided. (2) Responsibility. The owner of the structure shall provide and maintain mechanical and electrical facilities and equipment in compliance with these requirements. A person shall not occupy as owner-occupant or permit another person to occupy any premises which does not comply with the requirements of this section. (b) Reserved. (c) Mechanical equipment. (1) Mechanical appliances. All mechanical appliances, fireplaces, solid fuel-burning appliances, cooking appliances and water heating appliances shall be properly installed and maintained in a safe working condition, and shall be capable of performing the intended function. (2) Removal of combustion products. All fuel-burning equipment and appliances shall be connected to an approved chimney or vent. Exception: This provision shall not apply to fuel-burning equipment and appliances which are labeled for unvented operation. (3) Clearances. All required clearances to combustible materials shall be maintained. (4) Safety controls. All safety controls for fuel-burning equipment shall be maintained in effective operation. (5) Combustion air. A supply of air for complete combustion of the fuel and for ventilation of the space containing the fuel-burning equipment shall be provided for the fuel-burning equipment. (6) Energy conservation devices. Devices intended to reduce fuel consumption by attachment to a fuel-burning appliance, to the fuel supply line thereto, or to the vent outlet or vent piping therefrom, shall not be installed unless labeled for such purpose and the installation is specifically approved. (d) Electrical facilities. (1) Facilities required. Every occupied building shall be provided with an electrical system in compliance with the requirements of this section. (2) Service. The size and usage of appliances and equipment shall serve as a basis for determining the need for additional facilities in accordance with the NFPA 70 National Electrical Code. Dwelling units shall be served by a three-wire, 120/240 volt, single-phase electrical service having a rating of not less than sixty (60) amperes. (3) Electrical system hazards. Where it is found that the electrical system in a structure constitutes a hazard to the occupants or the structure by reason of inadequate service, improper fusing, insufficient receptacle and lighting outlets, improper wiring or installation, deterioration or damage, or for similar reasons, the Building Official shall require the defects to be corrected to eliminate the hazard. (e) Electrical equipment. (1) Installation. All electrical equipment, wiring, and appliances shall be properly installed and maintained in a safe and approved manner. (2) Receptacles. Every habitable space in a dwelling shall contain at least two (2) separate and remote receptacle outlets. Every laundry area shall contain at least one (1) grounded-type receptacle or a receptacle with a ground fault circuit interrupter. Every bathroom shall contain at least one (1) receptacle. Any new bathroom receptacle outlet shall have ground fault circuit interrupter protection. (3) Luminaries. Every public hall, interior stairway, toilet room, kitchen, bathroom, laundry room, boiler room, and furnace room shall contain at least one (1) electric luminaire. (f) Elevators, escalators and dumbwaiters. (1) General. Elevators, dumbwaiters, and escalators shall be maintained in compliance with Florida statutes and ASME A17.1. The most current certification of inspection shall be on display at all times within the elevator or attached to the escalator or dumbwaiter, or the certificate shall be available for public inspection in the office of the building operator. The inspection and tests shall be performed at not less than the periodical intervals listed in ASME A17.1, Appendix N, except where otherwise specified by the authority having jurisdiction. (2) Elevators. In buildings equipped with passenger elevators, at least one (1) elevator shall be maintained in operation at all times when the building is occupied. Exception: Buildings equipped with only one (1) elevator shall be permitted to have the elevator temporarily out of service for testing or servicing. (g) Duct systems. (1) General. Duct systems shall be maintained free of obstructions and shall be capable of performing the required function.

(Ord. No. 08-031, § 3, 11-18-08)

Ask a question about Boynton Beach law

Corpus searches the Boynton Beach sections it holds and shows the ones that match, with their citations. Free, no sign-in.