§ 3-2203 — Standards
Code of Ordinances of the City of Clearwater, Florida (Supp. No. 90: codified through Ordinance No. 9859-26, enacted January 15, 2026) · Clearwater Community Development Code § 3-2203
Corpus is an independent public-information project, not the official City of Clearwater website. Stable reference: corpuslaw.us/code/f63d043f-20f3-4e1c-a29b-356adb8fd7c6
Section 3-2203. - Standards.
Transit shelters may be established in accordance with the following standards: A. Spacing. No shelter may be erected or maintained where in the reasonable judgment of the city's traffic engineer it interferes with a traffic control device. Transit shelters containing advertising shall be located a minimum of 1,000 linear feet from another transit shelter containing advertising measured along the same side of the right-of-way unless approved for locations by the city manager pursuant to subsection (F) below. B. Location. 1. Transit shelters may be permitted in any commercial, office, mixed-use or industrial zoning district; or PSTA routes adjacent to hospitals, schools or other permitted non-residential uses in multifamily residential zoning districts. No transit shelters with advertising shall be permitted in single-family residential zoning districts. 2. Transit shelters shall not be placed on rights-of-way less than ten feet wide and shall not be placed in a location which interferes with any traffic control device. 3. Transit shelters may only be erected at approved bus stops on PSTA routes. 4. In order for transit shelters to be placed on private property, a letter of authorization from the property owner must be included with the application to the city. Notification must also be received from the PSTA that a shelter is needed and is appropriate in a particular proposed location where adequate public right-of-way does not exist. C. Design. Shelter design and specifications shall meet the requirements of and be approved by the PSTA. The contractor shall be responsible for adhering to the southern building and electrical code standards for shelter design, construction and installation. PSTA and the city shall be entitled to inspect the work and enforce these standards. Materials shall be chosen for ruggedness and ability to withstand vandalism and weathering. Shelters will be maintained by the contractor in accordance with PSTA specifications. Transit shelters shall meet the following minimum design specifications: 1. Transit shelters shall be not less than seven feet high (interior), no more than ten feet high (exterior), and shall have a minimum of two wall panels. 2. Shelters shall provide protection from wind, sun and rain. 3. Shelters shall offer see-through visibility, except for the sign panels. 4. Access to shelters shall be provided at least through the front, the right-of-way side of the shelter. 5. Shelters shall meet all ADA requirements with wheelchair space within the shelter and access to the interior of the shelter through at least a 30-inch wide opening, and shall not obstruct a wheelchair user boarding or alighting from an accessible vehicle. 6. Shelters shall have seating that accommodates a minimum of four people unless a smaller shelter is approved by the PSTA. Seats shall be not less than 16 inches nor more than 24 inches high. 7. Shelters shall contain a panel four feet wide by three feet high, in order to accommodate transit information, a route map, and other schedule information. 8. Shelters shall be constructed of material designed to withstand vandalism and weathering, such as extruded aluminum with anodized finish. 9. Transparent vertical panels shall be composed of a minimum one-quarter inch tempered glass except that the sign panel may be three sixteenths inch tempered glass. High impact strength polycarbon may be substituted for the tempered glass. 10. Materials and design shall conform to city and state building code specifications and shall be able to withstand 120 mile per hour wind loads. 11. A concrete pad which is a minimum of eight feet long by four feet wide shall be provided at each shelter. 12. Where the transit shelter is erected within an area designated by a corridor plan adopted by the city, the city may require that the shelter comply with special design criteria. D. Shelters shall include a trash receptacle which shall be secured in a manner which ensures that the receptacle will not become a nuisance. Shelters may be equipped with a telephone. E. Utilities. If transit shelters are erected on the public right-of-way over underground public utility lines, then the city shall have the right of access to the underground public utilities in and under the transit shelters to repair any damage to the utilities. The owner of the transit shelter shall be responsible for repairing and replacing the transit shelters if the city damages them in connection with repairing underground utilities. Except in emergency situations, the city shall notify the owner of the transit shelter prior to commencing repair activities. F. The city manager may authorize the placement of transit shelters with advertising closer than 1,000 linear feet from another transit shelter with advertising in the following instances: 1. Where two or more PSTA routes follow the same right-of-way and transit shelters are required by PSTA on the same side of the right-of-way; or 2. Where the transit shelter is erected as a part of and in accordance with the requirements of a corridor plan or redevelopment plan adopted by the city, including, without limitation, any special design criteria adopted as part of the corridor or redevelopment plan; or 3. Where the PSTA notifies the city that more than one transit shelter is desired along the same PSTA route less than 1,000 feet from another transit shelter erected pursuant to this division because of ridership or use demands, the close proximity of PSTA routes, requests from riders or other similar reasons. If a transit shelter is authorized by the city manager pursuant to this subsection, there shall be a minimum of 500 linear feet between transit shelters containing advertising and no more than three transit shelters containing advertising in any 2,000 foot linear segment measured from the two transit shelters located the greatest distance from each other.
(Ord. No. 6526-00, § 1, 6-15-00; Ord. No. 8988-17, § 19, 2-2-17)
Ask a question about Clearwater law
Corpus searches the Clearwater sections it holds and shows the ones that match, with their citations. Free, no sign-in.
