For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 3-804 — Height requirements

Code of Ordinances of the City of Clearwater, Florida (Supp. No. 90: codified through Ordinance No. 9859-26, enacted January 15, 2026) · Clearwater Community Development Code § 3-804

Corpus is an independent public-information project, not the official City of Clearwater website. Stable reference: corpuslaw.us/code/0cec0e85-ce39-4a88-82b0-27b783f932c4

Section 3-804. - Height requirements.

The following height requirements shall apply to all fences and walls, except chain link fences. A. Front. Fences and walls located between the principal structure and front property line shall be permitted to a maximum height of four feet. Any fence or wall that exceeds three feet in height shall provide a three-foot-wide landscaped strip on the right-of-way side of the fence or wall consistent with the general landscaping standards in Section 3-1202 unless otherwise determined by the Community Development Coordinator. Additional fence height may be approved consistent with the following exceptions: 1. In the LDR, LMDR, MDR and MHDR zoning districts, brick or other masonry walls with columns linked by substantial grill work may be permitted to a maximum height of six feet in a required front setback area as a Level One (flexible standard development) approval. Such walls shall be architecturally compatible with the principal structure on the property and compatible with the surrounding properties. 2. a. In the HDR, MHP, C, T, O, I, IRT, OSR, and P zoning districts, a fence or wall may be permitted up to a maximum height of six feet in front of a principal structure provided the fence or wall is primarily open style, with separated pickets or a combination of brick or other masonry columns linked by substantial grillwork. Any other style of fence or wall may be requested as a Level One (flexible standard development). b. In the area of the T District governed by Beach by Design residential uses may request a fence or wall up to a maximum height of six feet, and all other uses may request a fence or wall up to a maximum height of four feet as a Level One (flexible standard development) provided the fence or wall is primarily open style, with separated pickets or a combination of brick or other masonry columns linked by substantial grillwork, meets the design guidelines of Beach by Design, and is integrated into any required landscaping. 3. Walls up to a maximum height of six feet, may be permitted for the perimeter of any residential subdivision located within any zoning district. Such walls shall be architecturally compatible with the building design within the subdivision. 4. Corner and multi-frontage lots may be permitted a fence to a maximum height of six feet pursuant to Section 3-804.C. Fences and Walls: Front [image omitted; see the official code] B. Side and rear. Fences and walls shall be permitted to a maximum height of six feet between the principal structure and any side or rear property line with the following exceptions: 1. Fences and walls may be permitted up to eight feet in height if located in the IRT District. 2. Fences and walls may be permitted up to eight feet in height in the Commercial District through a Level One (Flexible Standard Development) approval to buffer uses with drive-thru facilities, vehicle sales/displays, automobile service stations, outdoor retail sales, display and/or storage and residential zoning districts. If any fence is part of a Level Two review, the decision to approve the fence will be made by the Community Development Board. 3. On those properties adjacent to water, fences proposed to be located within 20 feet of the property line adjacent to the water or within the required setback, whichever is greater, must be non-opaque and cannot exceed four feet in height. Fences and Walls: Side and Rear [image omitted; see the official code] C. Corner and multi-frontage lots. For the purposes of fence or wall placement on corner or multi-frontage lots, the front shall be the front property line from which the property is addressed, and all other front property lines will be treated as a side property line(s), as illustrated below for the purpose of fencing. The placement of any fence or wall on the front of the property shall adhere to the provisions in Section 3-804.A.1 through 3, above. A fence or wall may be permitted on the side property line in compliance with the provisions in Section 3-804.B., above, provided: 1. The fence is consistent with the character and placement of any structures and setbacks on the adjoining properties, including the placement of the fence on the property line, as determined by the Community Development Coordinator. 2. The fence or wall shall be primarily open style, with separated pickets. 3. If the side of the property is adjacent to a right-of-way that would be classified as an arterial or collector right-of-way by the City Engineer, then the fence or wall may be constructed consistent with the provisions in Section 3-804.B., above, regardless of the placement of structures on and setbacks of adjoining properties, and may be solid/opaque. 4. Any fence or wall that exceeds three feet in height shall provide a three-foot-wide landscaped strip on the right-of-way side of the fence or wall consistent with the general landscaping standards in Section 3-1202 unless otherwise determined by the Community Development Coordinator. Fences and Walls: Corner Lots [image omitted; see the official code] Fences and Walls: Multi-Frontage Lots [image omitted; see the official code] Non-Opaque/Open Style or Picket Fence Examples [image omitted; see the official code] D. Double frontage lots. For the purposes of fence or wall placement on double frontage lots, the front shall be the front property line from which the property is addressed, and the opposite front property line will be treated as a rear property line for the purpose of fencing as illustrated below. The placement of any fence or wall on the front of the property shall adhere to the provisions in Section 3-804.A., above. A fence may be permitted on the rear property line in compliance with the provisions in Section 3-804.B., above provided the following conditions exist: 1. The rear of both the adjacent lots on the same side of the street are oriented the same as the lot on which the fence or wall is proposed; and 2. The pattern of the dwellings across the street is also oriented with the rear facing the lots across the street. 3. If both of the above conditions cannot be met, such fence or wall in the rear shall not exceed four feet in height. 4. If the rear is adjacent to a right-of-way that would be classified as an arterial or collector right-of-way by the city engineer, then the fence or wall may be constructed consistent with the provisions in Section 3-804.B., above, regardless of any of the above conditions. Fences and Walls: Double Frontage Lots [image omitted; see the official code] E. Exception for attached dwellings. No fence or wall over six feet in height shall be permitted on any attached dwelling lot, except where the fence or wall is installed along the boundary of the property, in which case the fence or wall shall be uniformly designed and shall meet the height limits and other standards otherwise applicable to the fence or wall. F. Retaining walls, not including those walls associated with a detention pond which are regulated by Section 3-901, may be located between the principal structure and any front, side, or rear lot line, provided no portion of the wall that is located above grade exceeds 18 inches in height unless otherwise required to be of a greater height to satisfy and environmental or engineering need as determined by the city engineer. G. An equivalent combination of fence, wall, landscape berm or retaining wall may be utilized to achieve the maximum possible fence height; however, in no case shall the combined height of the structures exceed the maximum height provisions. H. Exception for gates, arbors, trellises, pergolas, and similar entry components. Gates, arbors, trellises, pergolas, and other similar entryway/access-enabling components incorporated into a fence or wall opening may include a height of no more than eight feet overall and may extend no more than one foot horizontally on each side of the opening and no more than three feet from the face of the fence or wall.

(Ord. No. 6526-00, § 1, 6-15-00; Ord. No. 6928-02, §§ 44—45A, 5-2-02; Ord. No. 7835-07, § 12, 1-17-08; Ord. No. 8070-09, § 4, 12-3-09; Ord. No. 8349-12, § 31, 9-6-12; Ord. No. 8715-15, § 13, 6-18-15; Ord. No. 9643-23, § 6, 4-4-23; Ord. No. 9758-24, § 15, 6-6-24)

Ask a question about Clearwater law

Corpus searches the Clearwater sections it holds and shows the ones that match, with their citations. Free, no sign-in.