§ 47.054 — Amendments to the Florida Building Code

Code of Ordinances of the City of Clearwater, Florida (Supp. No. 90: codified through Ordinance No. 9859-26, enacted January 15, 2026) · Clearwater Community Development Code § 47.054

Corpus is an independent public-information project, not the official City of Clearwater website. Stable reference: corpuslaw.us/code/199373b3-c182-4af0-8a6b-3c9e7c727bdf

Sec. 47.054. - Amendments to the Florida Building Code.

(1) The Florida Building Code, Building is adopted in section 47.051 of this Code, with the following administrative amendment(s): (a) Florida Building Code, Building Section 107.3.5, is amended to read as follows: 107.3.5 Minimum plan review criteria for buildings. … Residential (one- and two-family): … 6. Structural requirements shall include: … Flood hazard areas, flood zones, design flood elevations, lowest floor elevations, enclosures, declaration of land restriction (nonconversion agreement), equipment, and flood damage-resistant materials. (2) Florida Building Code, Building is adopted in section 47.051 of this Code, with the following technical amendment(s): (a) Florida Building Code, Building Section 202, definition of Substantial Improvement, is amended to read as follows: SUBSTANTIAL IMPROVEMENT. Any combination of repair, reconstruction, rehabilitation, alteration, addition or other improvement of a building or structure, taking place during a one-year period in which the cumulative cost equals or exceeds 50 percent of the market value of the building or structure before the improvement or repair is started. For each building or structure, the one-year period begins on the date of issuance of a certificate of completion/certificate of occupancy or completion of final inspection if such a certificate is not applicable for improvement or repair of that building or structure subsequent to November 20, 2003. If the structure has incurred "substantial damage," any repairs are considered substantial improvement regardless of the actual repair work performed. The term does not, however, include either: 1. Any project for improvement of a building required to correct existing health, sanitary or safety code violations identified by the building official and that are the minimum necessary to assure safe living conditions. 2. Any alteration of a historic structure provided that the alteration will not preclude the structure's continued designation as a historic structure. (b) Florida Building Code, Building Section 1612.4 Design and Construction, is amended to read as follows: … 1612.4 Design and construction. … 1612.4.1 Modification of ASCE 24. Reserved. 1612.4.2 Modification of ASCE 24 (Coastal A Zone). Section 4.5.13 in ASCE 24 shall be modified as follows: 1. Paragraph 1 shall be modified: "In Coastal High Hazard Areas and Coastal A Zones, stem walls shall not be permitted." 2. Paragraph 2 shall be deleted. 1612.4.3 Elevation requirements. The minimum elevation requirements shall be as specified in ASCE 24 or the base flood elevation plus 2 feet (610 mm), whichever is higher. (3) The Florida Building Code, Existing Building, is adopted in section 47.051 of this Code, with the following technical amendment(s): (a) Florida Building Code, Existing Building Section 202, definition of Substantial Improvement, is amended to read as follows: SUBSTANTIAL IMPROVEMENT. For the purpose of determining compliance with the flood provisions of this Code, means any combination of repair, reconstruction, rehabilitation, addition, or other improvement of a building or structure taking place during a one year period, in which the cumulative cost equals or exceeds 50 percent of the market value of the building or structure, before the improvement or repair is started. For each building or structure, the one-year period begins on the date of issuance of a certificate of completion/certificate of occupancy or completion of final inspection if such a certificate is not applicable for improvement or repair of that building or structure subsequent to November 20, 2003. If the structure has incurred "substantial damage," any repairs are considered substantial improvement regardless of the actual repair work performed. The term does not, however, include either: 1. Any project for improvement of a building required to correct existing health, sanitary, or safety code violations identified by the building official and that are the minimum necessary to ensure safe living conditions. 2. Any alteration of a historic structure, provided that the alteration will not preclude the structure's continued designation as a historic structure. (4) The Florida Building Code, Residential, is adopted in section 47.051 of this Code, with the following technical amendments: (a) Florida Building Code, Residential Section R322.2.1, Elevation Requirements, is amended to read as follows: R322.2.1 Elevation Requirements. 1. Buildings and structures in flood hazard areas including flood hazard areas designated as Coastal A Zones, shall have the lowest floors elevated to or above the base flood elevation plus 2 feet, or the design flood elevation, whichever is higher. 2. In areas of shallow flooding (AO Zones), buildings and structures shall have the lowest floor (including basement) elevated to a height above the highest adjacent grade of not less than the depth number specified in feet (mm) on the FIRM plus 2 feet, or not less than 4 feet if a depth number is not specified. 3. Basement floors that are below grade on all sides shall be elevated to or above base flood elevation plus 2 feet, or the design flood elevation, whichever is higher. Exception: Enclosed areas below the design flood elevation, including basements with floors that are not below grade on all sides, shall meet the requirements of Section 322.2.2. (b) Florida Building Code, Residential Section R322.3.2, Elevation Requirements, is amended to read as follows: R322.3.2 Elevation Requirements. 1. Buildings and structures erected within coastal high-hazard areas and Coastal A Zones, shall be elevated so that the bottom of the lowest horizontal structure members supporting the lowest floor, with the exception of pilings, pile caps, columns, grade beams and bracing, is elevated to or above the base flood elevation plus 2 feet or the design flood elevation, whichever is higher. 2. Basement floors that are below grade on all sides are prohibited. 3. The use of fill for structural support is prohibited. 4. Minor grading, and the placement of minor quantities of fill, shall be permitted for landscaping and for drainage purposes under and around buildings and for support of parking slabs, pool decks, patios and walkways. 5. Walls and partitions enclosing areas below the design flood elevation shall meet the requirements of Sections R322.3.4 and R322.3.5. (c) Florida Building Code, Residential Section R322.3.3, Foundations, is amended to delete the "Exception" and now reads as follows: R322.3.3 Foundations. Buildings and structures erected in coastal high-hazard areas and Coastal A Zones shall be supported on pilings or columns and shall be adequately anchored to such pilings or columns. The space below the elevated building shall be either free of obstruction or, if enclosed with walls, the walls shall meet the requirements of Section R322.3.4. Pilings shall have adequate soil penetrations to resist the combined wave and wind loads (lateral and uplift). Water-loading values used shall be those associated with the design flood. Wind-loading values shall be those required by this Code. Pile embedment shall include consideration of decreased resistance capacity caused by scour of soil strata surrounding the piling. Pile systems design and installation shall be certified in accordance with Section R322.3.6. Spread footing, mat, raft or other foundations that support columns shall not be permitted where soil investigations that are required in accordance with Section R401.4 indicate that soil material under the spread footing, mat, raft or other foundation is subject to scour or erosion from wave-velocity flow conditions. If permitted, spread footing, mat, raft or other foundations that support columns shall be designed in accordance with ASCE 24. Slabs, pools, pool decks and walkways shall be located and constructed to be structurally independent of buildings and structures and their foundations to prevent transfer of flood loads to the buildings and structures during conditions of flooding, scour or erosion from wave-velocity flow conditions, unless the buildings and structures and their foundations are designed to resist the additional flood load.

(Ord. No. 9189-18, § 3, 11-1-18)

Ask a question about Clearwater law

Corpus searches the Clearwater sections it holds and shows the ones that match, with their citations. Free, no sign-in.