Sec. 51.1004. - Accessory structures.
Accessory structures, as defined in this chapter, that are located in coastal high hazard areas (Zone V/VE), special flood hazard areas (Zone A/AE), or both areas are permitted below the base flood elevation provided such structures are in compliance with the following standards: (1) Those accessory structures located in Zone V/VE shall not be located below elevated buildings and shall not be larger than 100 square feet in size; (2) Those accessory structures located in Zone A/AE shall be one-story in height and no larger than 600 square feet in size, and shall have flood openings in accordance with Section R322.2 of the Florida Building Code, Residential; (3) Such structures shall only be used for parking and storage purposes; (4) Such structures shall be anchored to resist floatation, collapse or lateral movement resulting from flood loads; (5) Such structures shall have flood damage-resistant materials used below the base flood elevation plus two feet; and (6) Such structures shall have mechanical, plumbing, and electrical systems, including plumbing fixtures, elevated to or above the base flood elevation plus two feet.
(Ord. No. 9508-21, § 5, 11-4-21)