For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

C-602 — Façade treatment and design

Code of Ordinances of the City of Clearwater, Florida (Supp. No. 90: codified through Ordinance No. 9859-26, enacted January 15, 2026) · Clearwater Community Development Code § C-602

Corpus is an independent public-information project, not the official City of Clearwater website. Stable reference: corpuslaw.us/code/82e48c1e-dc0c-4598-88a9-52b795336108

Section C-602. - Façade treatment and design.

A. Complementary Design. All buildings and structures in projects with multiple buildings and structures, including parking structures, shall have complementary architectural details, materials, colors, and design treatments. For the purpose of this section, buildings and structures shall include primary buildings, accessory structures, parking structures, open air enclosures, fences and walls, and other vertical improvements. The intent of this provision is not to require a single design theme or motif for projects with multiple buildings and/or multiple tenants but to ensure a consistent level of quality in the design and detailing of buildings, parking structures, and other vertical improvements. B. Façade Articulation. 1. Buildings shall be designed with clearly articulated bases to define the extent of the public realm, provide spatial enclosure, and mediate differences in scale between adjacent buildings. Building bases shall constitute the façades of the first one or two stories of the building. Distinctions between building bases and upper story façades shall be established through the use of changes in material and color, the use of minor step backs for upper story façades, and architectural molding, cornice lines, or other modest projections. 2. To break up building façades along street frontages, façades shall be divided vertically into bays, as illustrated in Figure 31. Façade Bays & Articulation. Façade bay widths shall range between 20 to 35 feet establishing a rhythm of vertical modules unified by a complementary rhythm of windows and window groupings. Façade bays shall be distinguished by varying fenestration patterns, recessing wall planes, varying building materials, or establishing a rhythm of architectural elements such as pilasters or window bays. Figure 32. Façade Bays & Articulation [image omitted; see the official code] Figure 33. Corner Treatments [image omitted; see the official code] 3. To avoid flat, continuous façades above the ground floor on all building sides, the maximum length of an upper floor façade section shall be between 80 and 120 feet and the articulation between upper floor façade sections shall be accomplished by recessing the façade 2 feet minimum for a distance of at least 10 feet as illustrated in Figure 31. Façade Bays & Articulation. 4. Vertical or horizontal changes in the plane of a building façade for step backs, façade articulation, or other purposes shall be differentiated by architectural features including but not limited to coping, balustrades, cornice lines, change in materials, or changes in color. 5. Blank sections of ground floor building façades fronting streets, public spaces, and surface parking areas shall not exceed 20 feet in length. Elements such as windows, doors, balconies, columns, pilasters, changes in material, or other architectural details that provide visual interest shall be distributed across the façade in a manner consistent with the overall design of the building. C. Façade Materials. All building façades within view of a public street, pedestrian walkway, waterfront, or other public space, including side and rear façades, shall be constructed of high quality materials such as brick, stone, architectural block, concrete with an architectural finish, and traditional cementitious stucco. Side and rear façades shall use materials and design features similar to or complementary to those of the front façade. The use of metal façades shall not be permitted. D. Upper Floor Façade Fenestration. To minimize blank façade areas along street frontages, façades fronting streets and new primary drives shall provide fenestration (doors, windows or other openings) to an extent of a minimum of 20 percent of each floor's façade area as measured between finished floor and finished ceiling. E. Prohibited Glass Treatments on Ground Floors. The use of reflective, translucent, fritted, and other forms of non-transparent glass in wall and window systems on ground floor façades is prohibited. F. Corner Façades. 1. To create a seamless transition between the façades of a building at a street corner, both street-facing façades shall be designed with equal architectural quality and detail as illustrated in Figure 32. Corner Treatments. 2. Façade materials, window and wall treatments, and design elements such as signs and awnings shall be included on both sides of the building façade. Additional corner emphasis with chamfered or rounded façades, corner entries accentuated through changes in design treatments, materials, canopy projections, roof or parapet forms, or through other architectural methods is required. G. Parking Structures Design. 1. Parking structures shall be designed with architecturally-finished façades that complement the details, materials, colors, and design treatments of buildings in the project to contribute positively to the overall character of a project. 2. The ground level façades of parking structures along Service Street Types, public alleys, private drives, private service drives, and pedestrian walkways shall be designed with architectural screening of openings, trellis or canopy projections, or other architectural treatments to create safe, comfortable, and quality pedestrian environments. H. Security and Hurricane Protection. 1. Security bars are prohibited on windows or doors visible from public streets, public sidewalks, or public spaces. 2. Hurricane shutters, if provided, shall be fitted as an integral part of the storefront design, not visible when not in use, and only be used during the time frame in which a formally issued hurricane warning is in effect. I. Façade Lighting. Light emitting diode (LED) rope/ribbon lighting, neon lighting, or other types of lighting used to outline windows, or other architectural features shall be prohibited.

(Ord. No. 9149-18, § 8, 8-2-18; Ord. No. 9643-23, § 31, 4-4-23; Ord. No. 9712-23, § 11, 11-2-23; Ord. No. 9740-24, § 11, 2-1-240)

Ask a question about Clearwater law

Corpus searches the Clearwater sections it holds and shows the ones that match, with their citations. Free, no sign-in.