Sec. 10-70. - Accessory structures.
Accessory structures are permitted below the base flood elevation provided the accessory structures are used only for parking or storage and: (1) If located in special flood hazard areas (zone A/AE) other than coastal high hazard areas, are one (1) story and not larger than six hundred (600) square feet. (2) If located in special flood hazard areas (zone A/AE) other than coastal high hazard areas, have flood openings in accordance with Section R322.2 of the Florida Building Code, Residential, as amended. (3) Are anchored to resist flotation, collapse or lateral movement resulting from flood loads. (4) Have flood damage-resistant materials used below the base flood elevation plus one (1) foot. (5) Have mechanical, plumbing and electrical systems, including plumbing fixtures, elevated to or above the base flood elevation plus one (1) foot.
(Ord. No. 2021-009, § 3, 4-22-21)