Sec. 6-51. - Policy

(a) No water service connection to any premises shall be installed or maintained by the water purveyor including the service connections to premises constructed prior to the effective date of this article unless the water system is protected as required by state laws, regulations, and this article. Service of water to any premises shall be discontinued by the water purveyor if a backflow prevention assembly required by this article is not installed, tested, certified and maintained, or if it is found that a backflow prevention assembly has been removed, bypassed, or if an unprotected cross connection exists on the premises. The director of utilities and engineering department shall notify the city's fire rescue department of such cases in a timely manner. Service shall not be restored until such conditions or defects are corrected. (b) The customer side of the system shall be open for inspection at all reasonable times to authorized representatives of the City of Coconut Creek Utilities and Engineering Department, the City of Coconut Creek Utilities Division, and the City of Coconut Creek Chief Plumbing Official or other building or plumbing officials with jurisdiction to determine whether cross connections or other structural or sanitary hazards, including violations of the provisions of this article, exist. Water service may be discontinued after notice to the owner if a violation of this article exists on the premises, and such other precautionary measures may be taken as are deemed necessary to eliminate any danger to the potable water. Water service shall not be restored until the danger has been eliminated in compliance with the provisions of this article. (c) A backflow prevention assembly shall also be installed on each service line to a customer system at or near the property line or immediately outside the building being served; but, in all cases, before the first branch line leading off the service line wherever the following conditions exist: (1) In the case of premises having any auxiliary water supply, the utility system shall be protected against backflow from the premises by installing a backflow prevention assembly in the service line appropriate to the degree of hazard as described in section 6-51(d) and (f). (2) In the case of premises on which any auxiliary water supply or industrial fluids system is utilized, the utility system shall be protected against backflow from the premises by installing a backflow prevention assembly in the service line appropriate to the degree of hazard as described in section 6-51(e). (3) In the case of premises having internal cross connections or intricate plumbing and piping arrangements, the utility system shall be protected against backflow from the premises by installing a backflow prevention assembly in the service line appropriate to the degree of hazard as described in section 6-51(e). (4) In the case of fire protection systems see section 6-51(f). (d) The type of protective device required under Section 6-51(c)(1), (2), and (3) shall depend upon the degree of hazard which exists as follows: (1) In the case of any premises where there is an auxiliary water supply as stated in section 6-51(c)(1) and it is not subject to sections 6-51(d)(2), (3), (4), (5), (6), the utility system shall be protected by an air-gap separation or a reduced-pressure backflow prevention assembly. (2) In the case of any premises where a non-health hazard exists these systems shall be protected by a double check valve assembly. (3) In the case of any premises where there is any material dangerous to health which is handled in such a fashion as to create an actual or potential hazard to the utility system, the utility system shall be protected by an air-gap separation or a reduced-pressure backflow prevention assembly. (4) In the case of any premises where there are either actual or potential cross connections, the utility system shall be protected, by a backflow preventer on exterior water faucets, and an air-gap separation or a reduced-pressure backflow prevention assembly at the water service connection. The type of backflow prevention assembly shall be determined by the level and degree of hazard as outlined in sections 6-51(b), (e) and (g) of this article. (5) In the case of any premises where, because of security requirements or other prohibitions or restrictions, it is impossible or impractical to make a complete in-plant cross connection survey, the utility system shall be protected against backflow or backsiphonage from the premises by a reduced pressure backflow prevention assembly at each domestic water service connection, a pressure vacuum breaker at each meter for irrigation systems, and a double detector check valve assembly for fire protection systems. (6) In the case of any premises where a health threat is posed because of the presence of extremely toxic substances, an air-gap separation shall be required before any takeoff from the service line, after the water meter, but within the premises, at the first point of water discharge. (e) A backflow prevention assembly of the type designated shall be installed on each domestic water service connection to the following types of facilities. This list is presented as a guideline with respect to the facilities listed and is not to be construed as being complete. Abbreviations are as follows: A.G. — Air Gap Separation R.P. — Reduced-Pressure Backflow Prevention Assembly D.C.V.A. — Double Check Valve Assembly P.V.B. — Pressure Vacuum Breaker A.V.B. — Atmospheric Vacuum Breaker TYPE OF FACILITY | MINIMUM TYPE OF PROTECTION Breweries, Distilleries, Bottling Plants | R.P. Car Wash with recycling system and/or wax educator | R.P. Chemical Plants | R.P. Dairies | R.P. Dentist Office | R.P. Dwellings served by a master meter | D.C.V.A. Fertilizer Plants | R.P. Film Laboratory or Processing Plat | R.P. Food or Beverage Plant | R.P. Hospitals, Clinics, Medical Buildings | R.P. (Parallel) Irrigation Systems | R.P. or P.V.B. Laboratories | R.P. Laundries & Dry Cleaning Plants | R.P. Machine Tool Plants (Health or System Hazard) | R.P. Machine Tool Plants (Pollutional Hazard) | R.P. Metal Processing Plant (Health or System Hazard) | R.P. Metal Processing Plant (Pollutional Hazard) | R.P. Metal Plating Plant | R.P. Morgues or Mortuaries | R.P. Multi-Story Buildings served by a master meter | D.C.V.A. Nursing Homes | R.P. Packing Houses or Rendering Plants | R.P. Paper Products Plants | R.P Pesticides (Exterminating Companies) | A.G. Petroleum Processing Plant | R.P. Petroleum Storage Yard (Health or System Hazard) | R.P. Petroleum Storage Yard (Pollutional Hazard) | R.P. Pharmaceutical or Cosmetic Plant | R.P. Piers, Docks or Water Front Facilities | R.P. Power Plants | R.P. Radioactive Material Plants | R.P. Restaurants | R.P. Sand and Gravel Plants | R.P. Schools | R.P. Sewage Pumping Stations | R.P. Shops (Retail and Wholesale) | R.P. Swimming Pools with Piped Fill Line | A.G. at pool Veterinary Establishments | R.P. (f) Due to the variety of installation designs of fire systems which may preclude the use of a meter, the point of service shall be defined as the last valve prior to the outside stem and yoke (OS & Y) valve. A backflow prevention assembly of the type designated below shall be installed on the water service connection for each fire protection service to any premises. Fire protection systems are divided into six (6) general classes. The following are typical: MINIMUM TYPE OF PROTECTION CLASS 1 D.C.V.A. | A closed automatic fire protection system without pumper connection, having 20 heads or less; CLASS 2 D.C.V.A. | A closed automatic fire protection system with pumper connection; CLASS 3 R.P. | A closed automatic fire protection system with pumper connection and an auxiliary water supply on or available to the premises; or an auxiliary water supply which may be located within 1,700 feet of the pumper connection; CLASS 4 R.P. | A closed automatic fire protection system with a closed pressure tank supply (this class may have a jockey pump interconnected with the domestic water supply and/or an air compressor connection); CLASS 5 R.P. | A closed automatic sprinkler system interconnected with an auxiliary water supply; CLASS 6 | Fire protection system used for the combined purposes of supplying the automatic sprinklers, hose lines, fire hydrants and standpipes and being used for industrial purposes. R.P. | (a) Self-draining fire hydrants on premises presenting a health or system hazard (i.e., chemical plants, petroleum storage plants, bulk storage yards, stock yards, sewer plants, or similar facilities) where ground seepage of toxic materials may occur. D.C.V.A. | (b) Self-draining fire hydrants on premises presenting a non-health hazard (i.e., parks, playfields, or similar facilities) where ground seepage of non-health hazard materials may occur. (g) A backflow prevention assembly shall be required in all premises not described in the previous sections, with exception of existing single-family dwellings. A backflow prevention assembly shall be required at each meter servicing irrigation and fire protection systems. (h) Approval of a backflow prevention assembly shall be evidenced by a "Certificate of Approval" issued by an AWWA-approved testing laboratory certifying full compliance with AWWA and A.S.S.E. standards and F.C.C.H.R. specifications. Backflow prevention assemblies that have been fully tested and have been granted a certificate of approval may be installed without further testing or qualification. (i) It shall be the duty of the owner at any premises where backflow prevention assemblies are installed to have certified inspections and operational tests made at least once per year. Failed inspections, or those instances where the director of the utilities and engineering department deems the hazard to be great enough, shall require tests at six-month intervals. These inspections and tests shall be at no cost to the City of Coconut Creek. There is no charge for premise permit for county-owned installations or certifications of backflow prevention assemblies owned and operated by the City of Coconut Creek. It shall be the duty of the director of the utilities and engineering department to see that timely tests are made in accordance with Section 4620.8(b) of the South Florida Building Code, as amended from time to time. These backflow prevention assemblies shall be repaired, overhauled or replaced at no cost to the City of Coconut Creek whenever such devices are found to be defective. The certified tester shall send two (2) certified records of such tests, repairs, overhaul or replacement, one (1) to the utilities division and one (1) to the City of Coconut Creek Building and Permitting Division or the municipal department with jurisdiction. (j) Nothing herein shall relieve the owner of the responsibility for conducting, or causing to be conducted, periodic surveys of water use practices on the premises to determine where there are actual or potential cross connections in the customer system through which contaminants or pollutants could backflow into the water system. (k) All presently installed backflow prevention assemblies than do not meet the requirements of this article shall be modified or replaced to satisfactorily protect the utility system. Whenever an existing backflow prevention assembly is moved from the present location, or the lack of maintenance constitutes a health hazard, the device must be recertified as correct for the new application in accordance with the sections 6-51(d), (e), (f) and must be subsequently reinspected.

(Ord. No. 145-95, § 2, 11-9-95; Ord. No. 2002-002, § 1, 2-28-02; Ord. No. 2021-014, § 4, 6-24-21)

Ask a question about Coconut Creek law

Corpus searches the Coconut Creek sections it holds and shows the ones that match, with their citations. Free, no sign-in.