§ 113-10 — Buildings and structures
City Code of the City of Coral Gables, Florida (Codified through Ord. No. 2026-40, enacted September 29, 2026. (Supp. No. 26, Update 1)) · Coral Gables City Code § 113-10
Corpus is an independent public-information project, not the official City of Coral Gables website. Stable reference: corpuslaw.us/code/14fb6b63-7394-423c-a21c-509ad70dacef
Sec. 113-10. - Buildings and structures.
(a) Design and construction of buildings, structures, and facilities exempt from the Florida Building Code. Pursuant to section 113-4(c), buildings, structures, and facilities that are exempt from the Florida Building Code, including substantial improvement or repair of substantial damage of such buildings, structures, and facilities, shall be designed and constructed in accordance with the flood load and flood resistant construction requirements of ASCE 24. Structures exempt from the Florida Building Code that are not walled and roofed buildings shall comply with the requirements of section 113-16. (b) Specific methods of construction and requirements. Pursuant to chapter 8, article III of the Miami-Dade County Code, the following specific methods of construction and requirements apply: (1) Elevation certificates. Amend Section 110.3 inspection requirements to require submission of FEMA Elevation Certificate (FEMA Form 086-0-33) for foundation and final inspections to certify elevations. (2) Dry floodproofing certificates. Amend Section 1612 flood hazard documentation to require use of FEMA Floodproofing Certificate (FEMA Form 086-0-34) for statements for dry floodproofing designs. (3) Limitations on enclosures under elevated dwellings. Enclosed areas shall: (i) have the minimum necessary access to allow for parking of vehicles (garage door), limited storage of maintenance equipment used in connection with the premises (standard exterior door), or entry to the elevated building (stairway or elevator); (ii) not have the interior portion partitioned or finished into separate rooms except for stairwells, ramps and elevators, unless a partition is required by the fire code. (4) Registered design professional required. Designs for foundations of dwellings in flood hazard areas shall be prepared and sealed by registered design professionals. (5) Coastal A zones: a. In the Florida Building Code, Residential, Section R322.3, in foundations remove the exception (stem wall foundations in coastal A zones); b. In the Florida Building Code, Building, Section 1612, delete and reserve Section 1612.4.1 (modification of ASCE 24 to permit dry floodproofing in coastal A zones); c. In the Florida Building Code, Building, Section 1612, add new Section 1612.4.3 as follows: 1612.4.3 Modification of ASCE 24 (Coastal A Zone). Section 4.5.13 in ASCE 24 shall be modified as follows: 1. Paragraph 1 shall be modified: "In Coastal High Hazard Areas and Coastal A Zones, stem walls shall not be permitted." 2. Paragraph 2 shall be deleted. (6) Critical facilities. Critical facilities shall be elevated or dry floodproofed to or above the 500-year (0.2 percent) flood elevation plus one foot. (7) Cumulative substantial improvement. In the Florida Building Code, Building and Florida Building Code, Existing Building, Section 202 definitions for the term "substantial improvement" shall be as follows: Substantial improvement. Any combination of repair, reconstruction, rehabilitation, alteration, addition, or other improvement of a building or structure taking place during a five-year period, the cumulative cost of which equals or exceeds 50 percent of the market value of the building or structure before the improvement or repair is started. The period of accumulation begins when the first improvement or repair of each building is permitted. If the structure has incurred "substantial damage," any repairs are considered substantial improvement regardless of the actual repair work performed. The term does not, however, include either: (1) Any project for improvement of a building required to correct existing health, sanitary, or safety code violations identified by the building official and that are the minimum necessary to assure safe living conditions. (2) Reserved. (c) Detached accessory structures. Detached accessory structures are permitted below the base flood elevation provided the accessory structures are used only for parking or storage and: (1) If located in special flood hazard areas (zone A/AE) other than coastal high hazard areas, are one-story and not larger than 600 square feet; (2) If located in special flood hazard areas (zone A/AE) other than coastal high hazard areas, have flood openings in accordance with Section R322.2 of the Florida Building Code, Residential; (3) If located in coastal high hazard areas (zone V/VE), are not located below elevated buildings and are not larger than 100 square feet; (4) Are anchored to resist flotation, collapse, or lateral movement resulting from flood loads; (5) Have flood damage-resistant materials used below the base flood elevation plus one foot; or (6) Have mechanical, plumbing, and electrical systems, including plumbing fixtures, elevated to or above the base flood elevation plus one foot. If served by electricity, have not more than one switch and one outlet located below the base flood elevation and connected to a ground fault interrupt breaker. (d) Temporary structures. Temporary development permits may be issued for certain types of structures (e.g., construction trailers, construction site offices) located temporarily on property, for not more than 180 days, without having to comply with the anchoring, elevation, and other requirements for buildings in flood hazard areas provided the following criteria are met: (1) The structure is mobile, or can be made so, and is capable of being removed from the site with a minimum of 36 hours' warning; (2) The applicant submits a plan for the removal of the structure, containing the following documentation: a. The name, address, phone number and emergency contact point of the individual responsible for the removal of the structure; b. The time at which the structure will be removed (i.e., a minimum of 72 hours in advance of the projected landfall of a hurricane); c. A copy of a contract or other suitable instrument with a trucking company to ensure the availability of removal of the structure when needed, together with the name, address, and emergency phone number of the responsible trucking company agent; d. Designation, accompanied by documentation (e.g., signed consent of the property owner), of a site outside the city to which the structure will be moved; and e. Signatures of the applicant, property owner on which the structure will be placed, and owner of the structure, agreeing to abide by the terms of the removal plan. (3) Upon review and approval by the floodplain administrator, the permittee shall provide a copy of the permit and removal plan to the local emergency management coordinator.
(Ord. No. 2021-18, § 2, 3-23-2021)
Ask a question about Coral Gables law
Corpus searches the Coral Gables sections it holds and shows the ones that match, with their citations. Free, no sign-in.
