For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 82-32 — Tree protection/relocation standards

City Code of the City of Coral Gables, Florida (Codified through Ord. No. 2026-40, enacted September 29, 2026. (Supp. No. 26, Update 1)) · Coral Gables City Code § 82-32

Corpus is an independent public-information project, not the official City of Coral Gables website. Stable reference: corpuslaw.us/code/1e4cb2aa-dd81-4223-b922-48fb1c7b4bab

Sec. 82-32. - Tree protection/relocation standards.

(a) During site development and construction all reasonable steps necessary to prevent tree abuse or the destruction or damaging of trees shall be taken. Trees destroyed or receiving major damage must be replaced by trees of equal environmental value as specified by the tree preservation agency before occupancy or use unless approval for their removal has been granted under a tree permit. Tree root protection zones are required for all trees that remain in place on site and for any trees relocated within the site. As a condition of approval of the site plan for this project and of the tree removal and relocation activities for a subject property, the following tree protection, root pruning, and tree relocation specifications shall be followed. Site plans shall be modified to provide for the protection of as much of the existing intact tree root systems and canopies as is possible. All permit/construction drawings of the site shall show the tree root protection zones, as prescribed by the tree preservation agency, as shaded areas and shall be further labeled as such on the drawings. This information shall be shown on all drawings that show any underground utility installations, including, but not limited to, irrigation, plumbing, electrical, or telecommunication lines, and aboveground walkways. Approval of the tree protection agency as related to these issues is a requirement for permitting. A copy of these specifications shall be provided by the city and shall be made part of the permit set plans and specifications associated with any permits issued for a project, and a copy shall be provided to all contractors or subcontractors working on the site. No permits shall be issued in conflict with these requirements without the written consent of the tree protection agency. Tree protection requirements for trees designated for preservation shall include, but not be limited to, the following: (1) Protective barriers shall be placed around each tree, cluster of trees, or the edge of the preservation area no less than six feet in radius from the trunk of any protected tree cluster or preservation area unless a lesser distance or alternative layout is specified by the tree protection agency. The goal of the protective barriers is to protect as much of the root zone within the drip line of the tree as possible and to protect the trunk of the tree from damage. Protective barriers shall be placed around each palm tree at no less than three feet in radius from the trunk of the palm. However, the tree root protection zone is based on the height of the palm, and a taller palm may require a larger protection zone, as determined by the tree preservation agency. If root pruned, appropriate bracing of the palm is required. In situations where trees have been transplanted to the planting site, the protective fencing shall be placed no closer to the tree than a point one to two feet outside the root ball. Protected areas shall be extended where necessary to encompass the protection of tree canopies as well. If trees are to be preserved in place and root pruning will be performed to accommodate new construction, then the root pruning locations shall be identified and approved by the tree protection agency and fencing shall be installed one to two feet outside of the root cut locations. The installation of the fencing shall be coordinated with any phased root pruning that must occur. Tree maintenance measures such as irrigation must be in place prior to any root pruning or transplanting. The tree preservation agency shall be called for an inspection of the installed fence prior to commencement of any activity on the site. Protective barriers shall be a minimum of four feet aboveground level [and] shall be constructed of two-inch by four-inch wood posts and cross members with orange or yellow plastic construction fencing attached, which shall remain in place until development is completed and the tree preservation agency has authorized their removal. On private property, two-inch by four-inch wood cross members may be omitted for larger protection areas at the discretion of the tree protection agency. All protective barriers shall remain in place throughout all phases of construction starting prior to the start of any construction or site development including tree removal or land clearing activities and continuing up to final site landscaping activities. Prior to removal of the fencing, a site inspection by the tree preservation agency will be required. A review of the plans will be made at this point in order to insure that all activities forthcoming will not violate the tree root protection zone as previously established. Only hand digging and grading activities will be permitted within the tree root protection zone. All surrounding areas must be graded to a point that meets the outside of the tree root protection zone. The tree root protection zone should be a minimum one foot away from the trunk for every one inch of trunk radius and at the discretion of the tree preservation agency. For example, a 24-inch DBH tree should have a minimum 12-foot radius tree root protection zone. No more than 25 percent of roots in this zone should be cut at one time. Additional cutting of more than 25 percent of the roots in this zone requires approval by the tree preservation agency and done under the directive of a certified arborist. Signs of rigid durable construction (minimum size of 8.5 inches by 11 inches) shall be placed so as to be clearly visible at 15-foot intervals or closer (in no case fewer than four signs) encircling the perimeter of each tree root protection zone fence, to read as follows: Tree Root Protection Zone No Work, No Vehicles and No Dumping. Contact person responsible for the site for information at___________________________.

(Ord. No. 2017-45, § 2(Att. A), 12-5-2017)

Ask a question about Coral Gables law

Corpus searches the Coral Gables sections it holds and shows the ones that match, with their citations. Free, no sign-in.