Sec. 12-290. - Architectural design standards.
(A) Garage standards. For any new development requiring site plan approval, garages must be arranged such that garage doors do not face the street unless located at least fifteen (15) feet behind the front door of the home. [image omitted; see the official code] Figure 8: Recommended garage locations (B) Front building projections. Building projections including porches and verandas (minimum ten (10) feet in width), bay or garden windows shall be allowed within the required front yard. (C) Building orientation. All new residential homes shall orient toward the street. The front doors shall face the street. (D) Translucent materials. All facades shall contain a minimum of fifteen (15) percent transparent or translucent materials. (E) Roof pitch. Pitched roofs, other than gambrel roofs, shall have a minimum pitch of 4:12. Flat roofs are only permitted over porches and utility rooms located at the rear of a dwelling, where the flat roof areas comprise nor more than twenty-five (25) percent of the total roof area of the building.
(Ord. No. 2002-35, § 1, 10-16-02; Ord. No. 2012-28, § 2(Exh. A), 12-5-12; Ord. No. O2023-007, § 2(Exh. A), 6-7-23)