For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 12-437.11 — Grading drainage and retention

Code of Ordinances of the City of Davie, Florida (Codified through Ordinance No. O2026-016, enacted September 3, 2026 (Supp. No. 76)) · Davie Code of Ordinances § 12-437.11

Corpus is an independent public-information project, not the official City of Davie website. Stable reference: corpuslaw.us/code/29a2a0b3-a5f1-4229-8ce2-8e601355b735

Sec. 12-437.11. - Grading drainage and retention.

(A) Use separation. Development with the RAC-AV shall utilize grade changes to separate different uses. (B) Barrier free access. Slopes for wheelchair accessibility shall not exceed one (1) in twelve (12), with a length not to exceed thirty (30) feet. (C) Detention and retention basins. Retention basins may have a safety ledge extending six (6) feet from the edge of the water and at a depth of two and one-half (2½) feet. Maximum slopes to the water line of retention basins may be thirty (30) percent or 3:1.

(Ord. No. 2004-001, § 4, 1-7-04; Ord. No. 2012-28, § 2(Exh. A)(§ 12-32.411), 12-5-12)

Ask a question about Davie law

Corpus searches the Davie sections it holds and shows the ones that match, with their citations. Free, no sign-in.