For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 6.5 — Wildfire Protection Zone

Code of Ordinances of the City of Daytona Beach, Florida (Codified through Ordinance No. 2026-59, enacted February 18, 2026. (Supp. No. 78)) · Daytona Beach Land Development Code § 6.5

Corpus is an independent public-information project, not the official City of Daytona Beach website. Stable reference: corpuslaw.us/code/43bf2e52-9251-4fc8-9346-aad5f1fd3347

Sec. 6.5. - Wildfire Protection Zone.

A. Purpose. The standards in this section are intended to create a low-fuel zone along those perimeters of new development that face heavily-wooded or vegetated areas posing a threat of wildfire impacts for areas within the municipal boundaries west of Interstate 95. The purpose of the zone is to provide space for fire suppression equipment and reduce exposure to radiant heat from wildfire. B. Wildfire Hazard Assessment. The Fire Chief shall perform a wildfire hazard assessment in conjunction with the City's review of a proposed development project west of I-95, if the proposed development site or any abutting property consists of or contains heavily wooded or vegetated areas. The assessment shall be based on the local area fire history; the size, location, and other relevant physical characteristics of the site and abutting properties; expected characteristics of the project development site after development; prevailing wind patterns and seasonal weather conditions; and any other factors that the Fire Chief may determine to be relevant. C. Creation of Wildfire Protection Zone. If the Fire Chief determines based on the assessment above that there exists a heightened hazard of wildfire, the Fire Chief may designate all or a portion of the proposed development site as a Wildfire Protection Zone. Within the Wildfire Protection Zone, the City may adjust certain development standards otherwise applicable under this Code, as provided below. D. Firewise Standards. The following firewise standards apply to any proposed development that is in whole or in part within the Wildfire Protection Zones: 1. The site plan shall include a firewise landscaping plan that addresses the firewise development standards referenced herein. 2. To the extent reasonably necessary to enable the City to respond to wildfires should they arise, the development shall include a path of sufficient width, cleared of all trees and other significant obstructions, to allow for access for emergency vehicles. The path shall generally be a minimum of 14 feet in width. Other than the clearance requirements above, there shall be no restrictions on the owner's use of the property and no requirement for conveyance of an easement or other dedication. 3. If the Fire Chief determines that there is a particularly elevated risk of wildfire, the City may require the project developer to undertake the following activities at the developer's cost, in order to reduce fuel material for wildfires: a. Tree canopies within 50 feet of any existing or proposed structure shall be thinned by tree removal or by pruning of branches such that there is no more than 75 percent crown closure. b. A prescribed burn shall be conducted, in compliance with procedures prescribed by the Fire Chief, as part of the clearing and grading of the project site. The developer shall be responsible for all costs to have City fire department staff and equipment present if determined necessary by the Fire Chief. If a prescribed burn is not feasible because of climatic conditions, smoke limitations, proximity of existing development, or other constraints, alternative fuel mitigation strategies shall be determined by the Fire Chief. Such activities shall be completed prior to issuance of building permits for the project; unless waived by the City, in which instance such activities shall be completed prior to issuance of certificates of occupancy. 4. Development projects are encouraged to meet the following development standards: a. Required trees should be planted at least 30 feet from any building, as measured from the trunk of the tree to the nearest point of the structure. b. Required planted trees should be located at least 30 feet from other trees, where possible. If not possible, trees should be spaced apart instead of clustered. c. Landscape plants within a Wildfire Protection Zone should be strategically placed within and adjacent to the Zone to create separation between plants or plant cluster for the purpose of retarding the spread of fire and reducing radiant heat generated from highly concentrated vegetated areas. d. Trees and landscaping should be fire resistant species, as determined with reference to professionally acceptable sources such as the U.S. Department of Forestry and the Florida Department of Agriculture. e. Irrigation systems shall be encouraged within the Wildfire Protection Zone, even where drought tolerant landscaping is proposed. f. Wooden fences are discouraged within the Wildfire Protection Zone, except where a sufficient clear zone occurs between the fence and the adjacent wooded or vegetated area to mitigate the potential wildfire threat posed by the wooded or vegetated area. E. Adjustment to Tree and Landscaping Standards. 1. In conjunction with the development of a proposed project wholly or partially within a Wildfire Protection Zone, or with the use of an existing developed property located west of I-95 and adjacent to or near heavily wooded or vegetated areas that in the Fire Chief's view create an elevated risk of the spread of wildfire, the tree and landscaping requirements of the standards of this Code may be waived or reduced as follows: a. Existing trees may be removed to implement the firewise standards of this section, and except for historic trees the tree replacement requirements set forth in this Code shall be administratively waived. Removal of historic trees will still require City Commission approval in accordance with this Code. b. The City may administratively waive or reduce landscaping standards to the extent reasonably necessary to meet the firewise standards referenced above. 2. The waivers and reductions granted pursuant to this Section 6.5.E are subject to the developer's or property owner's compliance with Section 6.5.F, below. F. Maintenance Plan. 1. The provisions of this Section 6.5.F apply to: a. Any developer required to provide a cleared path as referenced in Section 6.5.D.2; b. Any developer required to comply with the firewise standards referenced in Section 6.5.D.3; and c. Any developer or homeowner who has received an adjustment to tree or landscaping standards pursuant to Section 6.5.E, in consideration of voluntarily complying with the suggested firewise standards of Section 6.5.D. 2. The developer, or as applicable the homeowner, shall submit for City approval a maintenance plan that provides for continued compliance with the applicable firewise standards of this Section. The plan shall specify the type of maintenance activities required, and their location. The plan shall also identify the minimum maintenance schedule. 3. For subdivisions, the maintenance plan shall be incorporated into the conditions and restrictions of the recorded plat. For individual lots, the maintenance plan shall be incorporated into the approved site plan. 4. The developer, property owner's association, or homeowner responsible for compliance with the maintenance plan shall conduct vegetation maintenance within 14 days from the receipt of written notice of insufficient maintenance from the City. 5. Failure to comply with the provisions of a maintenance plan shall be a violation of this Code.

(Ord. No. 16-26, § 1(Exh. A), 1-20-2016)

Ask a question about Daytona Beach law

Corpus searches the Daytona Beach sections it holds and shows the ones that match, with their citations. Free, no sign-in.