Sec. 13-61. - Gasoline vapor systems for cooking or heating.
Gasoline and gasoline vapor systems used for cooking or heating shall bear the label of the Underwriters Laboratories, Inc., and shall conform to the following requirements: (1) Capacity of tanks of portable systems inside buildings. The storage tank of portable systems used inside of buildings shall not exceed one (1) gallon capacity. (2) Stationary stoves and heaters; installation; storage tanks. Stationary stoves and heaters shall be fastened to the floor or permanent foundations to prevent breaking the fuel line. Storage tanks of stationary stoves and heaters shall not exceed six (6) gallons in capacity and shall be buried underground not less than five (5) feet from any building and not less than ten (10) feet from any door or window. (3) Piping connecting tanks to stove or heater. Fuel piping connecting outside tanks to stationary stoves and heaters shall be installed according to the Florida Building Code. Fuel piping shall in no case be concealed behind walls or ceilings and shall be protected by sleeves where passing through floors, partitions or walls. Where piping is installed near electric wiring, the requirements of the National Electrical Code shall be observed. (4) Testing of tubing and pipework, emergency shut-off valve. Tubing and pipework shall be thoroughly tested in compliance with the Florida Building Code. Tubing or pipework shall be provided with the separate shut-off valve installed inside the building at a point easily reached in an emergency. (5) Reserve supplies of fuel. Reserve supplies of fuel shall be kept in containers conforming to the regulations for storage and handling of flammable liquids. (6) Installation aboveground floor of burners connected with underground pressure storage. Gasoline, gasoline vapor, fuel oil, or other burners connected with underground pressure storage shall not be installed above the ground floor in any building. (7) Storage of kerosene and other petroleum or coal tar products. Storage and use of kerosene or other products of petroleum or coal tar shall be under the following regulations: a. Kerosene or other products of petroleum or coal tar shall be kept in cans of approved construction and design, but such cans shall not be kept in any out-of-the-way recess or under any stairway or in any cellar or similar hazardous location. A fire extinguisher of a type recommended by the fire inspection division must be provided for this hazard. b. Not more than five (5) gallons of kerosene oil shall be kept in any household. All quantities in excess of five (5) gallons must be stored in approved tanks. Kerosene oil pressure tanks used in connection with household heating or cooking arrangements shall be of not more than ten-gallon capacity, and such tanks shall be kept outside of the building, at a distance of at least five (5) feet from the structure. c. Stationary kerosene oil pressure systems used in connection with household heating or cooking arrangements should bear the label of the Underwriters Laboratory, Inc. Such systems shall be equipped with approved antiflooding devices.
(Code 1953, § 17-3.13; Ord. No. C-67-41, § 2, 4-18-67; Ord. No. C-03-23, § 2, 7-1-03)
Ask a question about Fort Lauderdale law
Corpus searches the Fort Lauderdale sections it holds and shows the ones that match, with their citations. Free, no sign-in.