Sec. 14-13. - Site improvements, utilities and limitations.
(a) Minimum requirements. All proposed new development shall be reviewed to determine that: (1) Such proposals are consistent with the need to minimize flood damage and will be reasonably safe from flooding; (2) All public utilities and facilities such as sewer, gas, electric, communications, and water systems are located and constructed to minimize or eliminate flood damage; and (3) Adequate drainage is provided to reduce exposure to flood hazards; in Zones AH and AO, adequate drainage paths shall be provided to guide floodwaters around and away from proposed structures. (b) Sanitary sewage facilities. All new and replacement sanitary sewage facilities, private sewage treatment plants (including all pumping stations and collector systems), and on-site waste disposal systems shall be designed in accordance with the standards for onsite sewage treatment and disposal systems in Chapter 64E-6, F.A.C. and ASCE 24 Chapter 7 to minimize or eliminate infiltration of floodwaters into the facilities and discharge from the facilities into flood waters, and impairment of the facilities and systems. (c) Water supply facilities. All new and replacement water supply facilities shall be designed in accordance with the water well construction standards in Chapter 62-532.500, F.A.C. and ASCE 24 Chapter 7 to minimize or eliminate infiltration of floodwaters into the systems. (d) Limitations on placement of fill. Subject to the limitations of this chapter, fill shall be designed to be stable under conditions of flooding including rapid rise and rapid drawdown of floodwaters, prolonged inundation, and protection against flood-related erosion and scour. (1) Nonstructural fill in special flood hazard areas and non-special flood hazard areas. Nonstructural fill in special flood hazard areas and non-special flood hazard areas shall: a. Not raise the existing grade of a site on the outside of the footprint of the foundation to a grade that is higher than the average of the existing grade plus one (1) foot or the average height of the back of sidewalk or crown-of-road, whichever is lower. Additional fill to raise the grade higher than this limitation is permitted only if approved by the City Engineer. b. Be graded to provide adequate drainage and to transition to natural grade before the property line. c. Not prevent the free passage of floodwaters and waves. d. Not divert floodwater or deflect waves such that damage is sustained by adjacent or nearby property. (2) Structural fill in Zones AE, AH and AO. Structural fill intended to support buildings and structures shall comply with the requirements of the Florida Building Code, state and federal laws, and this chapter. (3) Nonstructural fill in coastal high hazard areas (Zone V) and Coastal A Zones. a. Minor grading and the placement of minor quantities of nonstructural, noncompacted fill shall be permitted around the perimeter of a building for landscaping, aesthetic and drainage purposes, provided the fill will wash out from storm surge and thereby render the building free of obstruction prior to generating excessive loading forces, ramping effects or wave deflection. Minor quantities of fill are subject to the limitation defined in section 14-13(d)(1)a. b. Nonstructural fill with finished slopes that are steeper than one (1) unit vertical to five (5) units horizontal shall be permitted only if an analysis prepared by a qualified registered design professional demonstrates no harmful diversion of floodwaters or wave run-up and wave reflection that would increase damage to adjacent buildings and structures. (e) Limitations on sites in coastal high hazard areas (Zone V) and Coastal A Zones. (1) In coastal high hazard areas and Coastal A Zones, alteration of sand dunes and mangrove stands shall be permitted only if such alteration is approved by the Florida Department of Environmental Protection and only if the engineering analysis required by Section 14-6(b)(2) of this chapter demonstrates that the proposed alteration will not increase the potential for flood damage. Construction or restoration of dunes under or around elevated buildings and structures shall comply with Section 14-17(e)(2) of this chapter. (2) Where authorized by the Florida Department of Environmental Protection or applicable local approval, sand dune construction and restoration of sand dunes under or around elevated buildings are permitted without additional engineering analysis or certification of the diversion of floodwater or wave run-up and wave reflection if the scale and location of the dune work is consistent with local beach-dune morphology and the vertical clearance is maintained between the top of the sand dune and the lowest horizontal structural member of the building.
(Ord. No. C-14-26, § 2, 6-17-14; Ord. No. C-23-46, § 2, 12-19-23)
Ask a question about Fort Lauderdale law
Corpus searches the Fort Lauderdale sections it holds and shows the ones that match, with their citations. Free, no sign-in.