§ 47-19.13 — Resiliency standards for tidal flood protection
Code of Ordinances, City of Fort Lauderdale, Florida (Supp. No. 67: codified through Ordinance No. C-26-32, enacted July 2, 2026) · Fort Lauderdale Unified Land Development Regulations § 47-19.13
Corpus is an independent public-information project, not the official City of Fort Lauderdale website. Stable reference: corpuslaw.us/code/d63a37f4-654c-480a-95bf-f12cd8d77bff
Sec. 47-19.13. - Resiliency standards for tidal flood protection.
A. The purpose of the regulations in this section is to establish a consistent minimum elevation for tidal flood barriers that will: 1. Provide a standard for flood mitigation infrastructure that serves as a barrier to tidal flooding, not seepage, by accounting for water levels predicted under combined conditions of sea level rise, high tides, and storm surge through the year 2070; and 2. Ensure new shoreline structures and major shoreline improvements are designed for use as tidal flood barriers through application of consistent standards that account for future predicted tidal flood conditions and coastal water levels associated with sea level rise in accordance with current regional sea level rise projections, as updated and adopted by the Broward County Board of County Commissioners. B. This section applies to all new tidal flood barriers, substantial repair or substantial rehabilitation to shorelines and shoreline structures, the installation of any fixed structures attached to tidal flood barriers (such as mooring structures), and existing shorelines or shoreline structures that allow intrusion of tidal waters. This section is not applicable to oceanfront beaches or shorelines seaward of the Coastal Construction Control Line. C. For the purposes of this section, the following terms, phrases, words, and their derivation shall have the meanings given herein, except when the context clearly indicates a different meaning. In the interpretation and application of this section, the definitions provided for herein shall control over definitions that may be included in other documents or manuals, including, but not limited to, the Florida Building Code. Words used in the present tense include the future tense, words in the plural number include the singular number, and words in the singular number include the plural number. The word "shall" is mandatory and the word "may" is permissive. 1. Bank means the level space separating a waterway from an inland area, often elevated and constructed of compacted soil. 2. Berm means an earthen mound designed with impermeability to resist the flow of tidal waters through it to an adjacent property or public right-of-way. 3. Green-grey infrastructure or green-grey materials means a combination of engineered and natural features that provide environmental qualities and ecosystem value. 4. Mooring structure shall have the same meaning as referenced in Section 47-19.3(a)(2). 5. North American Vertical Datum (NAVD88) means the vertical control for datum of orthometric height established for vertical control surveying in the United States of America based upon the General Adjustment of the North American Datum of 1988. 6. Public nuisance means a condition injurious to the public health or safety of the community or neighborhood, or injurious to any considerable number of persons, or a condition that obstructs the free passage or use, in the customary manner, of any public right-of-way. 7. Rip-rap means a foundation of unconsolidated boulders, stone, rubble, concrete without protruding rebar, or similar materials placed on or near a shoreline to mitigate wave impacts and prevent erosion. 8. Seawall means a vertical or near vertical (often interlocking) structure placed between an upland area and a waterway or waterbody for erosion and flood control. 9. Seawall cap means a concrete box structure (usually reinforced) that connects seawall panels, piles, and anchoring system (if present) together at the top. 10. Shoreline means a tidally influenced area where land meets water. 11. Shoreline structure means any natural topographic feature (such as a bank, earthen mound, etc.) or man-made barrier (such as a berm, green-grey infrastructure, rip-rap, erosion control structure, seawall, seawall cap, tidal flood barrier, etc.) that is located at the shoreline. 12. Substantial repair or substantial rehabilitation means: a. Any modification to the shoreline or a shoreline structure along more than fifty (50) percent of the length of the property's shoreline; or b. Any modification, or alteration of an existing shoreline structure, that exceeds fifty (50) percent of the fair market replacement cost of the existing shoreline structure. c. Strictly for purposes of defining "substantial repair" and "substantial rehabilitation," the term "shoreline structure" excludes docks, finger piers, piles and ancillary concrete footers but shall include concrete docks that are poured monolithically with the seawall cap. 13. Tidal flood barrier means any structure or shoreline feature including but not limited to, banks, berms, green-grey infrastructure, seawalls and seawall caps, or other infrastructure that impedes tidal waters from flowing onto adjacent property or public rights-of-way and located within or along a tidally influenced area. This definition is not meant to include rip-rap, derelict erosion control structures, permeable earthen mounds or other similar features that inherently do not function as a substantially impermeable water barrier to tidal flooding. 14. Tidally influenced area means the real property adjacent to, or affected by, a waterway with water level changes in response to the daily tide. D. Standards for shoreline structures. 1. All new or substantially repaired or substantially rehabilitated shoreline structures shall be designed and constructed to perform as tidal flood barriers. Tidal flood barriers shall have a minimum top elevation of five (5) feet NAVD88, except as provided herein. Applications for new or substantially repaired or substantially rehabilitated tidal flood barriers submitted prior to January 1, 2035, may be permitted at a minimum top elevation of four (4) feet NAVD88, provided that the tidal flood barrier is designed to accommodate a minimum elevation of five (5) feet NAVD88, by January 1, 2050. The city engineer may grant a waiver to waterfront properties containing a principal structure with a habitable finished floor elevation of less than four (4.0) feet NAVD88 for the construction of a tidal flood barrier with an elevation less than the minimum top elevation required in Section 47-19.13.D(1). The city engineer shall consider the potential for flooding of the habitable space as a result of the installation of the tidal flood barrier at the minimum top elevation and the prevailing maximum tidal elevations at the time of application. The waiver may be granted for a term not to exceed three (3) years. Waivers granted pursuant to this subsection shall become void either upon the expiration of the waiver's term or upon the transfer of the ownership of the property for which the waiver is granted, whichever occurs first. The city engineer may rescind a waiver or decline to grant an extension to the waiver in the event that the tidal barrier subject of the waiver was overtopped by tidal waters, failed to perform as a tidal flood barrier or if prevailing environmental conditions no longer support granting of the waiver. City engineer shall provide fifteen (15) days' notice of such revocation. 2. All property owners shall maintain a tidal flood barrier in good repair. A tidal flood barrier is presumed to be in disrepair if it allows tidal waters to flow unimpeded through the barrier and onto adjacent property or public right-of-way. Failure to maintain a tidal flood barrier in good repair shall be a citable offense. The owner of the tidal flood barrier shall demonstrate progress towards repairing the cited defect within sixty (60) days after receiving a citation and shall complete repairs within three hundred sixty-five (365) days after receipt of the citation. If the required repair or rehabilitation meets the substantial repair or substantial rehabilitation threshold, no later than three hundred sixty-five (365) days after receipt of the citation, the property owner shall design, obtain permits, cause to be constructed, and obtain final inspection approval of seawall improvements that meet the minimum elevation and design requirements. 3. Shoreline structures that do not prevent tidal waters from entering adjacent property or the public rights-of-way shall be improved, designed, and constructed to function as tidal flood barriers. Causing or allowing the trespass of tidal waters onto adjacent property or the public rights-of-way is hereby declared a public nuisance and a citable offense requiring abatement; however, existing tidal flood barriers that have been designed and constructed in accordance with the provisions of this section that are overtopped by tidal water shall not be considered a public nuisance or citable offense. Upon receipt of a citation, the owner shall demonstrate progress toward addressing the cited concern within sixty (60) days after receipt of the citation and complete the construction of an approved remedy no later than three hundred sixty-five (365) days after receipt of the citation. 4. Tidal flood barriers shall be designed and constructed to prevent tidal waters from flowing through the barrier, while still allowing for the release of upland hydrostatic pressure. 5. Caps added to an existing seawall or tidal barrier shall be at least as wide as the existing cap. 6. To the extent practicable, tidal flood barriers shall be designed and constructed to adjoin immediately proximate tidal flood barriers to close gaps and prevent trespass of tidal water. 7. All tidal flood barriers undergoing substantial repair or substantial rehabilitation shall be constructed along the property's entire shoreline. 8. All vertical bulkheads or seawalls constructed in marine waters where no previous seawall existed shall be provided with natural limerock rip-rap, or other approved habitat enhancement, at the waterward face of the bulkhead or seawall. 9. Property owners are encouraged to consider approaches and materials that enhance the biological value of traditional (flat surface) seawalls and flood barriers with the incorporation of living shoreline features, use of hybrid green-grey materials, and the use of biological forms, where practicable. 10. This section shall not be construed to require the installation of a seawall where other flood protection measures serve as an equally effective tidal flood barrier. 11. Tidal flood barriers capable of automatically being elevated in advance of high tides to prevent tidal flooding are permissible, provided that automation cannot require daily human intervention. 12. The top elevation of a new or modified tidal flood barrier shall not exceed the base flood elevation (BFE) as identified in the FEMA Flood Insurance Rate Map (FIRM) or six (6) feet NAVD88, whichever is lower. For properties within an X zone, the maximum tidal flood barrier elevation shall not exceed the natural elevation of the ground, as defined in subsection 47-2.2 (g)(1)(a); however, in the event of a conflict between Section 47-19.13.D.(1) of the ULDR and this sub-section, the requirements in Section 47-19.13.D.(1) of the ULDR shall govern. 13. The maximum top elevation of a retaining wall that is ancillary to a shoreline structure shall not exceed the top elevation of the shoreline structure. In the event of a conflict between subsection 47-19.5.B. Table 1, Note G: subsection 1.a.ii. of the ULDR and the requirements of this section, this section shall govern. E. Required disclosure in contracts for sale of real estate. In any contract for the sale of real estate located in tidally influenced areas of Fort Lauderdale executed after March 23, 2023, the seller shall include in the contract or a rider to the contract the following disclosure in not less than fourteen-point, capitalized, bold-faced type: THIS REAL ESTATE IS LOCATED IN A TIDALLY INFLUENCED AREA. THE OWNER MAY BE REQUIRED BY COUNTY OR MUNICIPAL ORDINANCE TO MEET MINIMUM TIDAL FLOOD BARRIER ELEVATION STANDARDS DURING CONSTRUCTION OR SUBSTANTIAL REPAIR OR SUBSTANTIAL REHABILITATION OF SEAWALLS, BANKS, BERMS, AND SIMILAR INFRASTRUCTURE OR WHEN REQUIRED TO ABATE NUISANCE FLOODING.
(Ord. No. C-23-05, § 1, 3-23-23)
Ask a question about Fort Lauderdale law
Corpus searches the Fort Lauderdale sections it holds and shows the ones that match, with their citations. Free, no sign-in.