§ 16-20 — Standard for repair, vacation, demolition, temporary board and seal, or abatement
Code of Ordinances, City of Gainesville, Florida (Supp. No. 64, Update 1: codified through Ordinance No. 2024-740, adopted November 6, 2025) · Gainesville City Code § 16-20
Corpus is an independent public-information project, not the official City of Gainesville website. Stable reference: corpuslaw.us/code/8313e716-6765-4987-aacd-d54e2a1759a9
Sec. 16-20. - Standard for repair, vacation, demolition, temporary board and seal, or abatement.
The following minimum standards shall be followed in substance by the enforcing official in ordering repair, vacation, demolition, temporary board and seal, and abatement: (1) The owner of a dangerous building shall be given the option, wherever possible, of either demolishing the building or repairing it so that it will no longer exist in violation of the terms of this article. (2) If a dangerous building is in such condition as to make it dangerous to the health, safety, or general welfare of its occupants, it shall be ordered to be repaired or demolished and brought up to code. The owner must apply for a board and seal permit as described in Chapter 6 of this Code. If the permit is granted, the building must be boarded and sealed until such time as it is demolished or repaired so that it is no longer in violation of the terms of this article. If the owner does not obtain a permit and board or seal the building within one month of the order to repair or demolish, the enforcing official shall order the owner to demolish and remove the building. If the owner does not begin to repair the building within six months of the order to repair or demolish, or the owner begins to repair the building and there is a cessation of normal construction or repair of more than six months, the enforcing official shall order the owner to demolish and remove the building. (3) Vacant property standards. The following are minimum vacant property standards to be adhered to when temporary board and seal is permitted. Compliance with these standards does not constitute repair of a dangerous building. a. For structures that are unoccupied for more than 30 days and are not secure, all window and door openings and other openings that allow access to the interior of the building and that are visible from the street shall be secured with a minimum of .177-inch thick clear or semi-clear shatter-proof polycarbonate material with a strength capable of sustaining impact without breaking or shattering, absent excessive force. Such sheeting shall be installed in a manner intended to provide an appearance approximating glass in the window casings and consistent in appearance with the surrounding surface in the case of all other openings that require securing. b. Structures that were permitted to be boarded and sealed prior to June 3, 2021, using materials other than polycarbonate material meeting the standards set forth in subsection a. above, shall have until September 3, 2021 to re-board the structure with polycarbonate material meeting the standards set forth in subsection a. above. c. Where there is an open construction permit for new construction or for sealing the window or door openings, or for weather related protection, states of emergency, or other temporary conditions lasting less than 30 days, window and door openings and other openings that allow access to the building shall be covered with polycarbonate material as described in subparagraph (3)a., above, or with plywood as follows: 1. Exterior grade sheathing plywood of three-eighths of an inch thickness or greater. 2. Plywood covers shall be nailed, screwed or bolted firmly over each opening. No splices or joints of any kind shall occur over openings. Plywood shall not project beyond the outside edges of casings around openings, or in the absence of casing, project no further than six inches beyond the openings. 3. Nails shall be a minimum of 8D common hot dip galvanized nails. Screws shall be a minimum of no. 10 wood screws. Bolts shall be approved by the enforcing official prior to use. 4. Nails or screws shall not be spaced more than 12 inches on center along edges nor more than one inch from each corner. d. The exterior surfaces of all buildings shall be protected against the elements and loss of aesthetic value by the application of paint or other approved protective materials applied in accordance with the manufacturer's specifications. The paint or other protective material must match the building colors. (4) In any case where hazardous lands exist, the hazardous conditions existing upon the lands shall be ordered to be abated by the means least expensive and least detrimental to the owner's property and to the public environment.
(Code 1960, § 8-8; Ord. No. 3527, § 1, 3-13-89; Ord. No. 980745, § 3, 9-25-00; Ord. No. 200720, § 1, 6-3-21)
Ask a question about Gainesville law
Corpus searches the Gainesville sections it holds and shows the ones that match, with their citations. Free, no sign-in.