§ 30-4.14 — Building design standards
Code of Ordinances, City of Gainesville, Florida (Supp. No. 64, Update 1: codified through Ordinance No. 2024-740, adopted November 6, 2025) · Gainesville City Code § 30-4.14
Corpus is an independent public-information project, not the official City of Gainesville website. Stable reference: corpuslaw.us/code/bbe8e2b3-e6e3-42b5-b7dd-519f1e7cd412
Sec. 30-4.14. - Building design standards.
A. Building massing. Large building volumes must be divided to appear as smaller volumes grouped together. Volume breaks may be achieved by volume projections and recesses, and varying heights and roof lines. Therefore, building facades must not exceed 60 feet along a street frontage without providing a substantial volume break such as a volume projection or recess, a tower or bay, or an architecturally prominent public entrance. The recesses and projections must have a minimum depth and width of ten feet. Figure V-16: Building Massing [image omitted; see the official code] B. Facade articulation. The standards contained in this section apply to multi-family, nonresidential and mixed-use buildings. Building facades along streets must maintain a pedestrian scale by integrating the following architectural elements: [image omitted; see the official code] 1. Façades may not exceed 20 horizontal feet without including at least one of the following elements: a. A window or door. b. Awning, canopy or marquee. c. An offset, column, reveal, void, projecting rib, band, cornice, or similar element with a minimum depth of six inches. d. Arcade, gallery or stoop. e. Complementary changes in façade materials or texture. 2. An expression line must be provided between the first and second stories delineating the transition between ground and upper floors. 3. Architectural treatments on the façade, such as cornices or expression lines, must be continued around the sides of the building visible from a street. 4. All building elevations (including secondary/interior side façades) must use similar materials and appearance as the front/street facade. C. Exterior building materials. The following exterior material standards are required for each elevation of each building in any project that: (a) is multi-family residential or mixed-use projects that include both residential and nonresidential uses; (b) meets the threshold of either intermediate or major development plan review; or (c) is greater than two stories and is located on a storefront street, principal street, or thoroughfare street. 1. Exterior materials must be durable and weather-resistant and must be applied and maintained in accordance with the manufacturer's specifications or installation instructions. 2. Because the overall palette of materials should not be overly complex, each elevation must be limited to no more than three materials. The material for trim, fascia, mechanical penetrations, and other similar features may be excluded from this material limitation. 3. Exterior material classifications on each elevation must meet the percentages in Table X: Exterior Building Material Percentages. Interior elevations that do not face a public street or sidewalk are exempt from the requirements of Table X. Material percentage calculations are based on the elevation area for each individual elevation excluding window glazing or door areas. a. Class I: Brick masonry; stone masonry; cast stone masonry; precast concrete-architectural finish; concrete-architectural finish; glass wall system; metal panel. b. Class II: Stucco; fiber cement panel; fiber cement lap siding; manufactured stone; wood. c. Class III: Concrete masonry unit-architectural finish; concrete masonry unit-unfinished; precast concrete-unfinished; concrete-unfinished; wood composite lap siding; EIFS (Exterior Insulation Finishing Systems); synthetic stucco. Table X: Exterior Building Material Percentages Development threshold | Class 1 % | Class II & III*% Intermediate project | 30 (min)—100 (max) | 0 (min)—70 (max) Major project | 60 (min)—100 (max) | 0 (min)—40 (max) d. Class III materials may not constitute more than 30 percent of any building elevation. Unfinished concrete, precast concrete or concrete masonry units may not be used on any building elevation facing a public street or sidewalk. Exterior Insulation and Finish System (EIFS) may only be located at least 12-feet above ground level, measured from the base of the subject elevation. 4. The appropriate reviewing authority may allow modifications of exterior building material standards, including allowing the use of alternative materials not listed in Table X, considering the degree that the proposed substitute material is substantially similar in durability and longevity. D. Glazing requirements. 1. Glazing percentages must be calculated as follows: [image omitted; see the official code] a. Nonresidential first floor: The area of glass between three feet and eight feet above finished floor, divided by the area of the building façade also between three feet and eight feet above finished floor. b. Nonresidential above first floor: The combined area of glass on all floors above the first divided by the total area of the building façade for those floors. c. Residential: The area of glass divided by the area of the façade. 2. The approving authority may allow reduced glazing and/or glass transmittance for places of religious assembly and schools. 3. There is no maximum limit on how much glazing may be provided. However, if glass walls are used, an architectural feature, such as a canopy/marquee, overhang, or a horizontal change in plane must be provided between the first and second floors to ensure pedestrian scale at the sidewalk level. 4. Windows and glass doors must be glazed in clear glass with 70 percent minimum transmittance. The use of reflective glass and reflective film is prohibited on the ground floor of all buildings. E. Building entrances. 1. Each building must include a primary public entrance oriented toward the public right-of-way, and may be located at the building corner facing the intersection of two streets. Additional entrances may be provided on other sides of the building. 2. Primary public entrances must be operable, clearly-defined, and highly-visible. In order to emphasize entrances, they must be accented by a change in materials around the door, recessed into the facade (alcove), or accented by an overhang, awning, canopy, or marquee. Primary public entrances must provide direct access to building areas dedicated to ground floor active uses specified in section 30-4.13. 3. All multi-family residential units along street frontages shall contain street facing entrances. Where a ground floor unit has an entrance from an interior hallway, a secondary entrance to the unit shall be provided with access to the adjoining sidewalk. 4. Building frontages for non-residential uses along the street must have functional entrances at least every 150 feet.
(Ord. No. 200730, § 3, 2-17-22)
Ask a question about Gainesville law
Corpus searches the Gainesville sections it holds and shows the ones that match, with their citations. Free, no sign-in.
