For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 6-4 — Tiny houses

Code of Ordinances, City of Gainesville, Florida (Supp. No. 64, Update 1: codified through Ordinance No. 2024-740, adopted November 6, 2025) · Gainesville City Code § 6-4

Corpus is an independent public-information project, not the official City of Gainesville website. Stable reference: corpuslaw.us/code/6bc88679-f106-41b5-aa4b-9c1d5b418051

Sec. 6-4. - Tiny houses.

(a) Scope. This section is applicable to tiny houses used as single dwelling units. Tiny houses must comply with the Florida Building Code except as otherwise stated in this section. (b) Definitions. The following words and terms, for the purposes of this section, have the meanings shown herein. Refer to the Florida Building Code for general definitions. Egress roof access window means a skylight or roof window designed and installed to satisfy the emergency and rescue opening requirements of Section R310.2. Landing platform means a landing provided as the top step of a stairway accessing a loft. Loft means a floor level located more than 30 inches (762 mm) above the main floor, open to the main floor on one or more sides with a ceiling height of less than six feet eight inches (2032 mm) and used as a living or sleeping space. Tiny house means a dwelling that is 400 square feet (37 square meters) or less in floor area excluding lofts. (c) Minimum ceiling height. Habitable space and hallways in tiny houses must have a ceiling height of not less than six feet eight inches (2032 mm). Bathrooms, toilet rooms, and kitchens must have a ceiling height of not less than six feet four inches (1930 mm). Obstructions including but not limited to beams, girders, ducts, and lighting, must not extend below these minimum ceiling heights. (1) Exception. Ceiling heights in lofts are permitted to be less than six feet eight inches (2032 mm). (d) Lofts. (1) Minimum loft area and dimensions. Lofts used as a sleeping or living space must meet the following minimum area and dimension requirements: a. Minimum area. Lofts must have a floor area of not less than 35 square feet (3.25 square meters). b. Minimum dimensions. Lofts must be not less than five feet (1524 mm) in any horizontal dimension. c. Height effect on loft area. Portions of a loft with a sloped ceiling measuring less than three feet (914 mm) from the finished floor to the finished ceiling may not be considered as contributing to the minimum required area for the loft. i. Exception. Under gable roofs with a minimum slope of six units vertical in 12 units horizontal (50 percent slope), portions of a loft with a sloped ceiling measuring less than 16 inches (406 mm) from the finished floor to the finished ceiling may not be considered as contributing to the minimum required area for the loft. (2) Loft access. The access to and primary egress from lofts may be any of the following types: a. Stairways. Stairways accessing lofts must comply with the Florida Building Code or with the following: i. Width. Stairways accessing a loft may not be less than 17 inches (432 mm) in clear width at or above the handrail. The width below the handrail may not be less than 20 inches (508 mm). ii. Headroom. The headroom in stairways accessing a loft may not be less than six feet two inches (1880 mm), as measured vertically, from a sloped line connecting the tread or landing platform nosings in the middle of their width. iii. Treads and risers. Risers for stairs accessing a loft may not be less than seven inches (178 mm) and not more than 12 inches (305 mm) in height. Tread depth and riser height must be calculated in accordance with one of the following formulas: 1) the tread depth shall be 20 inches (508 mm) minus four-thirds of the riser height; or 2) the riser height shall be 15 inches (381 mm) minus three-fourths of the tread depth. iv. Landing platforms. The top tread and riser of stairways accessing lofts must be constructed as a landing platform where the loft ceiling height is less than six feet two inches (1880 mm) where the stairway meets the loft. The landing platform must be 18 inches to 22 inches (457 to 559 mm) in depth measured from the nosing of the landing platform to the edge of the loft, and 16 to 18 inches (406 to 457 mm) in height measured from the landing platform to the loft floor. v. Handrails. Handrails must comply with Section R311.7.8. vi. Stairway guards. Guards at open sides of stairways must comply with Section R312.1. b. Ladders. Ladders accessing lofts must comply with the above regulations for stairways and with the following: i. Size and capacity. Ladders accessing lofts must have a rung width of not less than 12 inches (305 mm), and ten-inch (254 mm) to 14-inch (356 mm) spacing between rungs. Ladders must be capable of supporting a 200-pound (75 kg) load on any rung. Rung spacing must be uniform within ⅜ inch (9.5 mm). ii. Incline. Ladders must be installed at 70 to 80 degrees from horizontal. c. Alternating tread devices. Alternating tread devices accessing lofts must comply with Sections R311.7.11.1 and R311.7.11.2. The clear width at and below the handrails must be not less than 20 inches (508 mm). d. Ships ladders. Ships ladders accessing lofts must comply with Sections R311.7.12.1 and R311.7.12.2. The clear width at and below handrails must be not less than 20 inches (508 mm). e. Loft guards. Loft guards must be located along the open side of lofts. Loft guards must be not less than 36 inches (914 mm) in height or one-half of the clear height to the ceiling, whichever is less. (e) Emergency escape and rescue openings. Tiny houses must meet the requirements of Section R310 for emergency escape and rescue openings. (1) Exception. Egress roof access windows in lofts used as sleeping rooms are deemed to meet the requirements of Section R310 where installed such that the bottom of the opening is not more than 44 inches (1118 mm) above the loft floor, provided the egress roof access window complies with the minimum opening area requirements of Section R310.2.1.

(Ord. No. 171056, § 1, 12-6-18)

Ask a question about Gainesville law

Corpus searches the Gainesville sections it holds and shows the ones that match, with their citations. Free, no sign-in.