§ 42-51 — Specific standards, special flood hazard areas
Code of Ordinances, City of Hialeah, Florida (Supp. No. 45: codified through Ordinance No. 2026-048, adopted June 23, 2026) · Hialeah Code of Ordinances § 42-51
Corpus is an independent public-information project, not the official City of Hialeah website. Stable reference: corpuslaw.us/code/0c5aeb7f-bdb9-4790-994d-62a913f0792d
Sec. 42-51. - Specific standards, special flood hazard areas.
In areas of special flood hazard, residential and nonresidential, the following provisions and compliance with the Florida Building Code are required: (a) Residential construction. New construction or substantial improvement of any residential building shall have the lowest floor, including basement, equipment and mechanical items elevated to or above the highest elevation as prescribed in ASCE 24, or eight inches above the crown of the road or back of sidewalk elevation abutting the property, whichever is higher. If solid foundation perimeter walls are used to elevate a structure, openings sufficient to facilitate the equalization of hydrostatic forces on two sides of exterior walls in according to the standards of subsection (c) herein are required. (b) Nonresidential construction. New construction or substantial improvement of any commercial, industrial, or nonresidential building shall have the lowest floor, including basement, and equipment and mechanical items elevated either four inches above the base flood elevation, the crown of the road, or back of sidewalk elevation abutting the property, or to or above the elevation specified in ASCE 24, whichever is higher. Buildings located in A-zones may be floodproofed in lieu of being elevated provided that all areas of the building below the required elevation are watertight with walls substantially impermeable to the passage of water, and use structural components having the capability of resisting hydrostatic and hydrodynamic loads and the effect of buoyancy. A registered professional engineer or architect shall certify that the standards of this subsection are satisfied. Such certification shall be provided to the official as set forth in section 42-40(a)(3). If manual placement of floodproofing measures is required, an operational plan shall be required to describe the installation of the floodproofing measures. (c) Enclosures below the lowest floor. New construction and substantial improvements that include fully enclosed areas formed by foundation and other exterior walls below the lowest floor shall have the enclosures designed to allow for the entry and exit of floodwaters to automatically equalize hydrostatic flood forces on exterior walls. (1) Designs for complying with this requirement must either be certified by a professional engineer or architect or meet or exceed the following minimum criteria: a. Provide a minimum of two openings on different sides of each enclosed area, such openings shall have a total net area of not less than one square inch for every square foot of enclosed area subject to flooding; b. The bottom of all openings shall be no higher than one foot above adjacent interior grade; and c. Openings may be equipped with screens, louvers, valves or other coverings or devices; provided that such openings provide the required net area of the openings and permit the automatic flow of floodwaters in both directions. (2) Fully enclosed areas below the lowest floor shall solely be used for parking of vehicles, storage, and building access. Access to the enclosed area shall be minimum necessary to allow for parking of vehicles (garage door), limited storage of maintenance equipment used in connection with the premises (standard exterior door), or entry to the living area (stairway or elevator); and (3) The interior portion of such enclosed area shall not be finished or partitioned into separate rooms. (d) A non-conversion agreement will be required to be signed by the property owner for all new construction and substantial improvement that include enclosed areas below the base flood elevation. This agreement shall include but not be limited to the following statement: "I hereby understand and agree as the owner of this property that enclosed areas that are below the base flood elevation are to be used only for parking, access and storage. I agree not to improve, finish or otherwise convert any enclosed areas below the required elevation to habitable or living space. I understand and agree that the City reserves the right to inspect such enclosures for compliance with this provision. I understand that I must record this Agreement with the Clerk of the Courts of Miami-Dade County. I understand and agree that a construction permit will not be issued until this Agreement is executed. I understand and agree that the construction permit will not be finalized until this agreement is filed with the Clerk of the Courts." (e) Standard for recreational vehicles. All recreational vehicles must either: (1) Be on the site for fewer than 180 consecutive days; (2) Be fully licensed and ready for highway use (a recreational vehicle is ready for highway use if it is on its wheels or jacking system, is attached to the site only by quick disconnect type utilities and security devices and has no permanently attached additions); or (3) Meet all the requirements for manufactured homes in section 42-51(f). (f) Standards for manufactured homes: (1) All manufactured homes installed in the city shall be installed by an installer that is licensed pursuant to F.S. § 320.8249, and shall comply with the requirements of Chapter 15C-1, Florida Administrative Code, and the requirements of this article. (2) Manufactured homes shall be anchored to prevent flotation, collapse, and lateral movement. Methods of anchoring may include, but are not limited to, use of over-the-top or frame ties to ground anchors. This standard shall be in addition to and consistent with applicable State of Florida requirements for resisting wind forces. (3) All manufactured homes that are placed, replaced, or substantially improved in flood hazard areas shall be elevated on a permanent foundation such that the lowest floor is at or above the base flood elevation plus one foot. (4) Enclosed areas below elevated manufactured homes shall comply with the flood damage-resistant materials requirements of section 42-50(g) and the enclosure requirements of section 42-51(c). (5) Utility equipment that serves manufactured homes, including electric, heating, ventilation, plumbing, and air conditioning equipment and other service facilities, shall comply with the utility requirements of section 42-50 and the equipment requirements section 42-41(h). (g) New construction and substantial improvements shall be constructed with flood damage-resistant materials below the elevations required in section 42-51(a) and (b). (h) Electrical, heating, ventilation, plumbing, air conditioning equipment and other service facilities, including duct work, shall be elevated to or above the elevations required in section 42-51(a) and (b) or shall be designed so as to prevent water from entering or accumulating within the components during conditions of flooding. (i) Standards for accessory structures. Accessory structures are permitted below the base flood elevation provided the accessory structures are one-story and not larger than 600 square feet and comply with the wet floodproofing requirements of ASCE 24.
(Ord. No. 2009-102, § 1, 12-22-2009; Ord. No. 2022-105, § 1, 10-25-2022)
Ask a question about Hialeah law
Corpus searches the Hialeah sections it holds and shows the ones that match, with their citations. Free, no sign-in.