For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 5.24 — FOOD TRUCKS

Code of Ordinances of the City of Lakeland, Florida (Supp. No. 22: codified through Ordinance No. 6121, enacted December 1, 2025) · Lakeland Land Development Code § 5.24

Corpus is an independent public-information project, not the official City of Lakeland website. Stable reference: corpuslaw.us/code/fc1e270f-ba79-4013-877e-f1b878d8fe88

5.24 - FOOD TRUCKS

5.24.1 GENERAL DEVELOPMENT STANDARDS a. Where allowed in Table 2.3-1, no more than one (1) food truck shall be in operation on a given property as an accessory use to another permitted principal commercial use. Two or more food trucks may only be considered through a conditional use for a food truck court. b. With the exception of special events, such as food truck rallies which are approved through a special event permit, food trucks shall not be located within any public or private right-of-way. c. Food trucks, and any accessory outdoor tables or seating, shall be setback a minimum of five (5) feet from any sidewalks, ten (10) feet from any driveways and above ground utilities, fifteen (15) feet from any fire hydrants, and fifty (50) feet from any residentially-zoned property. d. Food trucks, and any accessory outdoor tables or seating, shall not block or otherwise impede access to any sidewalks, driveways, ADA accessible parking or fire lanes. e. Food trucks shall only be located on an improved, stabilized surface such as concrete, gravel, asphalt or other similar material. If located within an off-street parking area, any parking spaces used will count against the minimum parking ratio required to support the principal use of the property. The amount of parking used shall not result in a reduction of the number of available off-street parking required to support the principal use, as specified by Table 4.11-1. f. Solid waste collection receptacles shall be provided for use by food truck customers. All solid waste collected shall be properly disposed of either off-site or on-site within an approved solid waste collection bin (dumpster) through an agreement with the property owner. g. Electrical service may be provided by either an on-board generator or through a temporary electric connection, subject to compliance with all codes and any permitting requirements. Permanent connections for electrical service shall be prohibited. h. Liquid Waste Disposal 1. There shall be no discharge of liquid waste or grease trap waste into any storm or sanitary sewer system. Liquid waste shall be disposed of through one of the following methods: (a) A licensed contracted commissary or A licensed designated sanitary sewer disposal site. All commissaries and disposal sites must have approved grease traps, and monitoring manholes per City of Lakeland Standards and Specifications. (b) Direct connection to sanitary sewer by new or existing services. If a food truck is located on a property that has a grease trap and monitoring manhole approved by the Water Utilities Department, connection to the sanitary sewer shall require compliance with all water utility requirements and approval by the Water Utilities Department. If at any time the Water Utilities Department has concerns about the connection, immediate disconnection shall occur. 2. Disposal Documentation Log All food truck operators shall maintain a Disposal Documentation Log. The disposal log shall be kept in the food truck at all times and shall include date, time, address location, and the amount of liquid waste, grease or used cooking oil disposed. At the request of the Water Utilities Department and/or upon inspection, the food truck operator shall provide copies of the disposal log. The Disposal Documentation Log to be used by the food truck operator can be found on the City of Lakeland Water Utilities' website, or by contacting the department. i. Water Consumption 1. Water shall be provided from one of the following methods: (a) A licensed contracted commissary or A licensed designated potable water fill site There shall be no connection to any non-potable water source. All commissaries must have an approved backflow prevention device per City of Lakeland Standards and Specifications. (b) Direct connection to water by a new or existing domestic service. If a food truck is located on a property that has a City installed domestic water meter and backflow prevention device approved by the Water Utilities Department, connection to the water service line, downstream of the backflow prevention device, shall be in accordance with all water utility requirements. If at any time the Water Utilities Department has concerns with the connection, or the meter and/or backflow prevention device are bypassed, immediate disconnection shall occur. 2. Potable Water Acquisition Log: The food truck operator shall maintain a Potable Water Acquisition Log. The log shall be kept in the food truck at all times and shall include date, time, address location, and the amount of potable water obtained. At the request of the Water Utilities Department, and/or upon inspection, the food truck operator shall provide copies of the log. The Acquisition Log to be used by the food truck proprietor can be found on the City of Lakeland Water Utilities' website, or by contacting the department. 5.24.2 REQUIRED DOCUMENTATION a. All licensing and permitting of food trucks shall be done through the Department of Business and Professional Regulation in accordance with applicable state statutes. b. Prior to operating within the City of Lakeland, the food truck proprietor shall submit a Food Truck Sanitary Sewer Disposal & Potable Water Source Form to the City of Lakeland Water Utilities Department. This form, which can be found on the City of Lakeland Water Utilities' website or by contacting the department, must be completed and signed by the Water Utilities Department. c. In accordance with Section 78-4 (b) of the City of Lakeland Code of Ordinances, the proprietor shall also obtain written consent from the property owner which authorizes the food truck use and guarantees access to permanent bathroom facilities on the site. The Food Truck proprietor shall provide documentation of such consent upon request by City of Lakeland Code Enforcement Division. d. The food truck proprietor shall maintain a Disposal Documentation Log. The disposal log shall be kept in the food truck and shall include date, time, address location, and the amount of liquid waste, grease or used cooking oil disposed. Food Truck operator shall provide copies of the disposal log when requested by the Water Utilities Department and/or upon inspection.

(Ord. No. 5794, § 1.2(Att. B), 11-18-19) (Ord. No. 5794, § 1.2(Att. B), 11-18-19; Ord. No 6055, § 2(Att. A), 9-16-24)

Ask a question about Lakeland law

Corpus searches the Lakeland sections it holds and shows the ones that match, with their citations. Free, no sign-in.