Sec. 12-77. - Minimum standards for basic equipment and facilities.

No person shall occupy, or let to another for occupancy, any dwelling or dwelling unit, for the purpose of living, sleeping, cooking, or eating therein, which does not comply with the following requirements: (1) Every dwelling unit shall contain not less than a kitchen sink, lavatory, tub or shower and water closet, all in good working condition and installed in accordance with the Florida Building Code. Every sink, lavatory, tub or shower shall be supplied with adequate hot and cold water. (2) Every dwelling unit shall contain a room which affords privacy to a person within said room and which is equipped with a flush water closet and a lavatory basin in good working condition and properly connected to an approved water system and sewer system or an approved septic tank installation including an approved absorption bed. No privy shall be constructed or continued in operation after July 16, 1963. (3) Every dwelling unit shall contain a room which affords privacy to a person within said room and which is equipped with a bathtub or shower in good working condition and properly connected to an approved water system and sewer system or an approved septic tank installation including an approved absorption bed. (4) Every kitchen sink, lavatory basin, and bathtub or shower required under the provisions of this section shall be properly connected with both hot and cold water lines. (5) Every dwelling shall have water heating facilities which are properly installed, maintained in safe and good working condition, and properly connected with the hot water lines required under the provisions of the preceding paragraphs. Such water heating facilities shall be capable of supplying on demand to all the required fixtures a continuous supply of hot water, as spelled out below. The following shall be used as a minimum guide where central hot water is supplied for multifamily housing units: _____ Type of Apartments | Minimum Heater Input 1 | Minimum Storage Capacity Efficiencies and one-bedroom apartments | 3,825 BTU per hour per apartment | Eight gallons per apartment Two-bedroom apartments | 6,680 BTU per hour per apartment | Ten gallons per apartment Three-bedroom apartments | 9,545 BTU per hour per apartment | 12 gallons per apartment 1 Based on 70 percent fuel efficiency. If other than oil or gas is used an adjustment for fuel efficiency may be used. _____ Where dwelling units have individual water heaters, there shall be provided a system capable of supplying 140 degree water in an amount of 16 gallons per bedroom per three hours. An adequately designed solar system is acceptable if there is incorporated in the design a thermostatically controlled booster with Btu input equivalent to that specified above. Instantaneous or tankless systems are acceptable if they are designed to raise the required volume of water 70 degrees Fahrenheit. The required volume of water shall be determined by the fixture unit method as set forth in the National Bureau of Standards BMS 66. All such facilities shall be of an approved type, connected and maintained all as provided in the Florida Building Code and any fire regulations or ordinances now in existence or adopted subsequent hereto. (6) Every occupied dwelling unit shall be provided with an installed nonportable cooking facility which shall not be capable of being carried easily by one person, and shall have at least two top burners. Vacant dwelling units shall be provided with utility connections for such facility. (7) Every dwelling unit shall have adequate garbage disposal facilities or garbage storage containers. (8) Every dwelling structure and dwelling unit of types of construction I, II, III, IV and V as defined by the Florida Building Code shall have means of egress which conform to the standards of the Florida Building Code and any applicable fire codes, fire regulations or ordinances now in existence or adopted subsequent hereto. Every dwelling structure of type of construction V, built before December 31, 1957, where the structural and other elements of the building consist primarily of wood, having one or two dwelling units above the ground floor, shall have a minimum of two separate means of egress which are remote from each other or at least one means of egress with stairs that are constructed of either noncombustible materials or made safe by approved fire resistive modifications as may be required. Each such means of egress shall be easily accessible for every dwelling unit on the specified floor without passing through any other dwelling unit. Every dwelling structure of type of construction V, where the structural and other elements consist primarily of wood having three or more dwelling units, shall have means of egress which conform with the provisions of the Florida Building Code and any applicable fire codes, fire regulations or ordinances now in existence or adopted subsequent hereto. (9) In every owner-occupied dwelling unit not intended to be let for occupancy containing space heating facilities, such facilities shall be properly installed and maintained in safe and good working conditions as provided in the Florida Building Code and any applicable fire regulations or ordinances now in existence or adopted subsequent hereto. Every dwelling and dwelling unit which is let or intended to be let for occupancy shall have adequate space heating facilities which are properly installed and maintained in safe and good working condition as provided in the Florida Building Code and any applicable fire regulations or ordinances now in existence or adopted subsequent hereto. Adequate heating facilities are hereby defined as follows: a. Permanent space heating equipment capable of heating two-thirds of the habitable rooms to a minimum air temperature of 70 degrees Fahrenheit to be measured three feet above floor when outside temperature is 45 degrees Fahrenheit, or permanent space heating equipment with capacity of five Btu's per hour of input per cubic foot of habitable room space within two-thirds of the habitable rooms. b. The five Btu's per hour input standard is based on a heating unit with 70 percent rating of input-to-output efficiency; an appropriate correction factor will be applied when the proposed heating unit exceeds an input-to-output efficiency rating of 70 percent. Heating units supplied on the basis of this calculation will otherwise comply with the standards described elsewhere in this subsection. c. Permanent heating equipment is defined as heating equipment properly connected to a flue or vent or, if electric, properly installed and permanently connected to an adequately wired and sized branch circuit. d. Habitable room shall mean a room or enclosed floor space used or intended to be used for living, sleeping, cooking or eating purposes, excluding bathrooms, shower rooms, water closet compartments, laundries, pantries, foyers, connecting corridors, closets and storage spaces. e. Heating equipment shall be installed and maintained in accordance with the provisions of the Florida Building Code. f. Any calculations necessary for the installation of permanent heating equipment to assure adequate heating capacity as defined in this section, shall be made in accordance with the standards established in the current edition of the appropriate published by the American Society of Heating and Air-Conditioning Engineers, Inc., on file in the city offices. g. Oil heaters, gas heaters, and woodstoves must be connected to a properly installed vent, said vent conforming to the provisions of the Florida Building Code. h. Electric heaters will be of a type readily fixed into position and must be properly installed and permanently connected to an adequately wired and sized branch circuit. i. Any portable heating device approved by the Underwriters' Laboratories, Inc., or a properly installed fireplace may be used as an accessory heating unit. j. Accessory heating units will be deemed to be supplementary to the permanent heating equipment and shall not be considered when calculating the adequacy of the permanently installed heating equipment except as specified in subsection (9)(m) of this section. k. Only those accessory heating units which are acceptable under the provisions of the fire codes and standards, the state regulations, and other regularly adopted regulations will be used. l. The use of unsafe heaters or cooking stoves and the use of cooking stoves, including ovens, for heating purposes is hereby prohibited. m. The requirements of subsection (9) of this section shall not apply to dwelling units in existence on March 17, 1969, provided that either a gas pipe outlet or an electrical outlet and circuit are present for the use of gas space heaters or portable electrical space heaters.

(County Code, §§ 17-23, 17-59)

Ask a question about Miami Gardens law

Corpus searches the Miami Gardens sections it holds and shows the ones that match, with their citations. Free, no sign-in.