For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 30-64 — Specific standards

Code of Ordinances of the City of Miami Gardens, Florida (Codified through Ordinance No. 2026-005-494, adopted February 25, 2026 (Supp. No. 19)) · Miami Gardens Code of Ordinances § 30-64

Corpus is an independent public-information project, not the official City of Miami Gardens website. Stable reference: corpuslaw.us/code/70d97168-8891-4147-bc45-72ec3d30cf5a

Sec. 30-64. - Specific standards.

In all A-zones where base flood elevation data have been provided (zones AE, A1—30, and AH), as set forth in section 30-8, and in addition to section 30-63, the following provisions shall apply: (1) Residential construction. All new construction and substantial improvement of any residential building, including manufactured home shall at a minimum have the lowest floor, including basement, elevated to the base flood elevation plus 12 inches, and in accordance with the standards of section 30-36. Should solid foundation perimeter walls be used to elevate a structure, for those enclosed areas below the base flood elevation there must be a minimum of two openings on different sides of each enclosed area sufficient to facilitate automatic equalization of flood hydrostatic forces in accordance with standards of subsection 30-8(3). (2) Nonresidential construction. All new construction or substantial improvement of any commercial, industrial, or nonresidential building (including manufactured home) shall have the lowest floor, including basement, elevated to the base flood elevation plus 12 inches, and in accordance with the standards of section 30-36. All nonresidential buildings located in the city may be floodproofed, in lieu of being elevated, provided that all areas of the building components below the base flood elevation plus one foot, and as required in section 30-36 are water-tight with walls substantially impermeable to the passage of water, and use structural components having the capability of resisting hydrostatic and hydrodynamic loads and the effects of buoyancy. A registered professional engineer or architect shall certify that the standards of this subsection are satisfied by using the FEMA floodproofing certificate. Such certification along with the corresponding engineering data, and the operational and maintenance plans shall be provided to the floodplain administrator. (3) Elevated buildings. New construction or substantial improvements of elevated buildings that include fully enclosed areas formed by foundation and other exterior walls below the lowest floor elevation shall be designed to preclude finished living space for the enclosed areas, and shall be designed to allow for the entry and exit of floodwaters to equalize hydrostatic flood forces on exterior walls. a. Designs for complying with this requirement must either be certified by a professional engineer or architect or meet or exceed the following minimum criteria: 1. Provide a minimum of two openings on different sides of each enclosed area having a total net area of not less than one square inch for every square foot of enclosed area; 2. The bottom of all openings shall be no higher than one foot above adjacent interior grade (which must be equal to or higher in elevation than the adjacent exterior grade); 3. Openings may be equipped with screens, louvers, valves, or other coverings or devices provided they provide the required net area of the openings and permit the automatic flow of floodwaters in both directions; 4. Electrical, plumbing and other utility connections are prohibited below the base flood elevation; and 5. The interior portion of such enclosed area shall not be partitioned or finished into separate rooms. b. Fully enclosed areas below the base flood elevation shall be used solely for parking of vehicles, storage, and building access. Access to the enclosed area shall be the minimum necessary to allow for parking of vehicles (garage door), limited storage of maintenance equipment used in connection with the premises (standard exterior door), or entry to the living area (stairway, foyer or elevator); c. A non-conversion agreement will be required to be signed by the property owner for all new construction that includes enclosed areas below the base flood elevation. This agreement shall include but not be limited to the following: "I hereby understand and agree as the owner of this property that enclosed areas that are below the base flood elevation are to be used only for parking, access and storage. I agree not to improve, finish or otherwise convert any enclosed areas below the required elevation to habitable or living space. I understand and agree that the City of Miami Gardens reserves the right to inspect such enclosures for compliance with this provision. I understand that this Agreement will be recorded with the Clerk of the Courts of Miami-Dade County." (4) Standards for manufactured homes and recreational vehicles. a. All manufactured homes that are placed, or substantially improved within zones A1-30, AH, and AE, on sites: 1. Outside of an existing manufactured home park or subdivision; 2. In a new manufactured home park or subdivision; 3. In an expansion to an existing manufactured home park or subdivision; 4. In an existing manufactured home park; or 5. In a subdivision on which a manufactured home has incurred "substantial damage" as the result of a flood, shall have the lowest floor elevated on a permanent foundation to the base flood elevation plus 12 inches and be securely anchored to an adequately anchored foundation system to resist flotation, collapse, and lateral movement. b. All recreational vehicles placed on sites within zones A1-30, AH, and AE must either: 1. Be on the site for fewer than 180 consecutive days; 2. Be fully licensed and ready for highway use (a recreational vehicle is ready for highway use if it is on its wheels or jacking system, is attached to the site only by quick disconnect type utilities and security devices and has no permanently attached additions); or 3. Meet all the requirements for new construction, including anchoring and elevation requirements in accordance with sections 30-36 and 30-63. (5) [Drainage.] Adequate drainage, including on site retention and proper disposal of stormwater runoff, and paths around structures shall be provided to guide water away from structures.

(Ord. No. 2009-20-192, § 2(art. V, § B), 9-8-2009; Ord. No. 2021-009-439, § 4, 12-8-2021)

Ask a question about Miami Gardens law

Corpus searches the Miami Gardens sections it holds and shows the ones that match, with their citations. Free, no sign-in.