For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 505 — Accessory Uses and Standards

Code of the City of Miramar, Florida (Supp. No. 105: codified through Ordinance No. 26-10, adopted July 8, 2026) · Miramar Land Development Code § 505

Corpus is an independent public-information project, not the official City of Miramar website. Stable reference: corpuslaw.us/code/3f9a3f4b-512f-4ad8-bff1-c79316efa71c

Section 505. - Accessory Uses and Standards.

505.1. General Purpose. The purpose of this section is to provide clear guidelines and regulations for the use of accessory structures and land within residential, commercial, and industrial properties. The code outlines the acceptable types of accessory uses, establishes standards for their design and construction, and sets limitations on their size, location, and impact on the surrounding properties and community. This Code aims to strike a balance between the property owners' right to use their land and the need to preserve the safety, health, and welfare of the community. The regulations will help to ensure that accessory uses do not create nuisances, hazards, or other negative impacts on the surrounding properties and environment. No accessory uses shall be permitted in a required yard or bufferyard area, except as set forth in the code. In addition, no accessory use shall be authorized to permit a use not otherwise permitted in the district where the principal use is located and that no accessory use can be established prior to the principal use to which it is accessory. Permanent structures are also not allowed in utility easements without the written approval of the appropriate utilities and the concurrence of the city. By providing clear and concise regulations for accessory uses, this Code will promote orderly and efficient land use and development and protect the quality of life in the community. It will also provide property owners with the certainty they need to make informed decisions about the use of their land and accessory structures. 505.2 Other Accessory Uses. This Code provides guidelines for the majority of accessory uses that are permitted. However, there may be instances where accessory uses not specifically delineated in this Code section may be deemed acceptable. In these cases, approval of the accessory use may be granted by the Director of Planning or their designee. The Director will consider the specific circumstances of each case and make a determination based on the principles and similar uses outlined in this Code section, including compatibility with the surrounding properties, public health and safety, and preservation of the community's quality of life. Property owners seeking approval of an accessory use not specifically described in this Code section should submit a request in writing to the Director, along with any relevant information or plans. 505.3 Accessory Use Table and Specific Standards. The following table "TABLE 505-1" provides regulations for each accessory use permitted within the city limits. Some uses and structures require additional regulations which may be found in the corresponding sections stated within the table. TABLE 505-1 ACCESSORY USES USES | MAXIMUM AREA (square feet) | SPECIFICATIONS | MINIMUM FRONT SETBACK (feet) | MINIMUM SIDE SETBACK (feet) | MINIMUM REAR SETBACK (feet) | PROHIBITED ANTENNAS, ANTENNA TOWERS AND DISH ANTENNAS: | See Section 505.4 AWNINGS AND CANOPIES | N/A | See Section 505.5 | Same as structure | Same as structure | Same as structure CARPORT | N/A | N/A | Same as structure | Same as structure | Same as structure | Polyvinyl Chloride (PVC) pipe DOCKS | See Section 505.6 DUMPSTER/ COMPACTOR ENCLOSURE | N/A | See Section 505.7 | N/A | 10 | 10 | Within 25 feet of a residential structure FENCES AND WALLS | N/A | See Section 505.8 | N/A | N/A | N/A | Barbed wire in residential districts STRUCTURE; DETACHED | 750 | 1,000 square feet maximum for properties in the Rural, Estate, or Residential Single Family 1 zoning districts | Same as structure | Same as structure | Same as structure | No greater than half the square footage of the primary residence GAZEBO | 650 | 1,000 square feet maximum for properties in the Rural, Estate, or Residential Single Family 1 zoning districts | Not Permitted | 6 3 | 6 3 | within front yards or within utility, drainage, landscape bufferyard or access easements PATIOS (COVERED); SINGLE-FAMILY, DUPLEX, AND FEE-SIMPLE MULTI-FAMILY LOTS1 | N/A | Rural (RL), Estate (E), and Residential Single-Family 1 (RS1) | N/A | 25 | 25 | within utility, drainage, landscape bufferyard or access easements Single-family residential properties | N/A | Same as structure | 15 Attached multi-family units | N/A | 2 | 15 Zero-lot properties | N/A | 0/10 | 15 PATIOS (OPEN) AND DECKS; SINGLE-FAMILY, DUPLEX AND FEE-SIMPLE MULTI-FAMILY LOTS | N/A | Rural (RL), Estate (E), and Residential Single-Family 1 (RS1) | N/A | 25 | 25 | within utility, drainage, landscape bufferyard or access easements Single-family residential properties | N/A | 5 | 5 Attached multi-family units | N/A | 2 | 5 Zero-lot properties | N/A | 0/10 | 5 PERGOLA, TRELLIS | 1,000 | See Section 505.9 | Same as structure | 6 | 6 | within utility, drainage, landscape bufferyard or access easements PLAY EQUIPMENT | See Section 505.10 POOL AND SPA | N/A | See Section 505.11 | N/A | Open patios setback plus 2 feet to water's edge | Open patios setback plus 2 feet to water's edge | within front yards or utility, drainage, landscape bufferyard or access easements ROOFTOP PHOTOVOLTAIC SOLAR SYSTEMS | See Section 505.12 SCREEN ENCLOSURE4 | N/A | Screen roof | N/A | Same as structure | 5 3 | within front yards or easements Solid roof | Same as structure | 15 2, 3 | within front yards or easements UTILITY SHEDS | Maximum 240 sq. ft. Maximum height 10 feet | Rural (RL), Estate (E), and Residential Single-Family 1 (RS1) | N/A | 25 | 25 | within front yards or utility, drainage, landscape bufferyard or access easements Maximum 100 sq. ft. Maximum height 8 feet | Single-family, duplex, triplex residential properties | N/A | 3 | 3 Maximum 100 sq. ft. Maximum height 8 feet | Multifamily residential properties | N/A | Same as structure | Same as structure Maximum 200 sq. ft. Maximum height 10 feet | Non-residential properties | N/A | Same as structure | 10 UTILITY/ MECHANICAL EQUIPMENT | N/A | See Section 505.13 | N/A | Same as equipment height | Same as equipment height | within a utility easement unless it is equipment serving that specific easement WALKWAYS1, 5 | N/A | Single-family, duplex, triplex residential properties | N/A | 2 | 2 | within front yards or utility, drainage, landscape bufferyard or access easements 1 Drainage provision. Rainwater runoff must be maintained on the property. Rainwater shall not be allowed to flow onto or across any adjoining property or sidewalk, either public or private. Exception: Rainwater may flow into a street gutter, storm sewer, or storm sewer catch basin if first approved by the engineering department. 2 ;hg;Screen enclosures with a solid roof shall be 15' or the same as the structural setback, whichever is less. 3 ;hg;Except for RL, E and RS1 zoning districts, setbacks a minimun of 25'. 4 ;hg;No screen enclosure may be converted to an enclosed structure unless the proposed conversion complies with all standards of the applicable zoning district. 5 ;hg;The maximum width of the walkway for a residential home shall be no greater than 5 feet. 505.4 Antennas, Antenna Towers and Dish Antennas: 505.4.1 HAM radio antennas and towers. Antenna towers or antenna masts for use by amateur (HAM) radio operators who are licensed by the Federal Communications Commission shall be constructed in accordance with the following provisions: (a) The height of any such permitted tower or mast and antenna shall not exceed 55 feet when fully extended. (b) The height of any such push-up mast and antenna shall not exceed 35 feet when fully extended. (c) The maximum permitted width of a tower shall not exceed 18 inches on a square or triangular tower. (d) The maximum permitted diameter of a mast or push-up mast shall not exceed nine inches. (e) The antenna and all support structures and cables shall be located in the rear yard and meet the same setback requirements as the principal structure. (f) Shall comply with National Electric Code and Federal regulations governing amateur radio. (g) Must maintain an eight-foot clearance from pole lines. 505.4.2 Citizens' radio station. All antennas and supporting structures associated or used in conjunction with a citizens' radio station, licensed by the Federal Communications Commission, operated from a fixed location, must comply with one of the following provisions: (a) A ground mounted antenna and its supporting structure shall not exceed 20 feet in height above ground level. (b) An antenna attached to a man-made structure shall not be higher than 20 feet above the structure. No citizens' radio station antenna shall exceed a height of 40 feet from ground level. (c) The antenna and all support structures and cables shall be located in the rear yard and meet the same setback requirements as the principal structure. (d) Shall comply with National Electric Code and Federal regulations governing amateur radio. (e) Must maintain an eight-foot clearance from pole lines. 505.4.3 Dish antennas in residential zoning districts. Dish antennas shall be permitted in all residential zoning districts subject to the following criteria: (a) Location and setbacks. Except for roof-mounted antennas, all dish antennas shall be located to the rear of the principal building and shall not encroach into the following setbacks: (measured from edge of dish in the horizontal position). i. Rear yard. For ground mounted antennas the rear yard setback shall be equivalent to the height of the antenna or the structural setback applicable to the property, whichever is less. ii. Side yard. For all antennas, the minimum setback to a side lot line shall be the same as for a principal building in the district in which the antenna is located. (b) Maximum size. The maximum diameter of any dish antenna in a residential zoning district shall be 12 feet. (c) Maximum height. The maximum height of the various permitted antenna types shall be as follows. i. Roof mounted. The maximum height of any roof mounted dish antenna shall be no higher than the diameter of the dish. No residential structure under three stories in height shall mount an antenna on the roof. ii. Pole mounted. All pole mounted antennas shall be directly adjacent to and connected to the main structure, and shall extend no higher than six feet above the roof line. iii. Ground mounted. The maximum height of a ground mounted antenna shall be equal to the diameter of the dish. (d) Screening, ground mount. For ground mounted dish antennas, a fence, wall, hedge, trees, berm, or any combination thereof shall be provided as specified below to obscure the view of the antenna from adjacent parcels. Fences or walls used as screening shall be installed at a minimum height of five feet except where such height would interfere with the satellite signals to the extent of causing deterioration in reception quality. When screening material is provided on a property line or otherwise within normal required setback areas, the maximum height of the screening, except for trees, shall be six feet. When vegetative material other than trees is provided, the height at time of planting shall be a minimum of two feet and must attain opacity and a minimum height of three feet within one year from date of planting under normal growing conditions. (e) Number permitted. One dish antenna shall be permitted per single-family or duplex unit. For all other multi-family dwelling unit types only one dish antenna shall be permitted per unified development project, additional antennas may be permitted through conditional use approval. (f) Anchorage. Dish antennas shall be anchored securely to the ground or building and otherwise installed in conformance with the requirements of the South Florida Building Code, Broward County Edition. (g) Maintenance. Following installation, dish antennas and related appurtenances must be maintained in good operable condition and surrounding landscaping shall be maintained in good, healthy condition so as to provide maximum opacity. 505.4.4 Dish antennas in non-residential zoning districts. Dish antennas shall be permitted uses in all non-residential zoning districts subject to the criteria of this section. Dish antennas which do not meet the criteria of this section shall require conditional use approval. (a) Location and setbacks. Except for roof-mounted antennas, all dish antennas shall be located to the rear or side of the principal building and shall not encroach into the setbacks established herein. i. Rear yard. For ground mounted antennas the rear yard setback shall be equivalent to the height of the antenna or the structural setback applicable to the property, whichever is less. ii. Side yard. For all antennas, the minimum setback to a side lot line shall be the same as for a principal building in the district in which the antenna is located. (b) Maximum size. The maximum diameter of any dish antenna in a non-residential zoning district shall be 30 feet. If the antenna is proposed to be located on land adjacent to property designated residential on the land use plan or residentially zoned property, the maximum diameter of the dish shall be 12 feet. (c) Maximum height. The maximum height of ground mounted dish antennas shall be no higher than the dish's diameter or the height of a structure, whichever is less. The maximum height of a roof or pole mounted antenna shall be no higher than one and one-half times the height of a structure measured from the ground. (d) Screening, ground mount. Ground mounted antennas shall be screened around the base of the structure with a five-foot wide continuous landscape buffer. The minimum height of vegetation shall be three feet. (e) Number permitted. Only one antenna per united development or parcel of land shall be permitted. Additional antennas may be permitted through conditional use approval. (f) Anchorage. Dish antennas shall be anchored securely to the ground or building and otherwise installed in conformance with the requirements of the South Florida Building Code, Broward County Edition. (g) Maintenance. Following installation, dish antennas and related appurtenances must be maintained in good operable condition and surrounding landscaping shall be maintained in good, healthy condition to provide maximum opacity. 505.5 Awnings and Canopies. Except for single-family and duplex residences, awnings and canopies are subject to Community Appearance Board (CAB) approval. The accessory shall be architecturally integrated into the building's design and color. 505.6 Docks. The following section outlines the regulations for docks. These regulations are intended to ensure the safety of waterfront structures and maintain the aesthetic and environmental quality of the waterways. These regulations build upon existing guidelines while also taking into account the unique characteristics of the city's canal ways and lakes. 1. Location and Size: Docks may be permitted in any residential or commercial district on any waterway as an accessory use to a property. No boat landing, dock, pier, or mooring pile shall be constructed on a parcel of land which abuts or adjoins a body of water, the width of which body of water is less than 100 feet between the mean water's edge when measured perpendicular to the lot at any point of construction. No boat landing, dock, pier, or mooring pile shall be constructed on a lot which abuts or adjoins a body of water so that it extends as follows: (a) Into the body of water more than 25% of the width of the body of water, when the width of the body of water is measured between the mean water's edge perpendicular to the lot at any point of construction. (b) More than 20 feet beyond the mean water's edge, whichever of one or two is more restrictive and provides for the smaller dock. 2. Width and Height: No boat landing, dock, pier, or mooring pile shall be more than 20 feet in width, running parallel to the shoreline, and in no case shall the total area of the dock exceed 200 square feet. The dock height shall not exceed 5 feet above the mean water level. 3. Construction: No boat landing, dock, pier, or mooring pile shall be constructed without a permanent connection to the land. All docks shall be constructed of materials that are durable, weather-resistant, and non-polluting. The construction of all docks shall meet applicable engineering standards and the Florida Building Code. 4. Permitting: Prior to the construction of a dock, the owner shall obtain a permit from the community development department and appropriate drainage district. The permit shall include a survey as described in Section 318, a detailed site plan showing the location of the dock, its dimensions, the materials to be used, and any proposed lighting or other features. 5. Maintenance: Docks shall be kept in a constant state of repair by the owner. Any dock not properly constructed or maintained must be removed at the direction of the community development department within 15 days of receipt of notice. 6. Lighting: Any lighting associated with docks shall be designed and installed so as to minimize glare and light spillage onto adjacent properties and the waterway. 7. Easements: Approval must be obtained from applicable drainage districts for docks located in a maintenance or drainage easement. 8. Multiple Docks on non-residential parcels: Only on non-residential parcels, on lots having more than one building, no more than one dock shall be erected for each building fronting on a waterway. No more than two docks shall be permitted on any lot or adjacent thereto. 9. Environmental Protection: Docks shall be designed and constructed in a manner that minimizes adverse impacts to the waterway, including shoreline erosion, sedimentation, and water quality degradation. The owner shall comply with all applicable federal, state, and local laws and regulations related to environmental protection. 505.7 Dumpster and Compactor Enclosures. The following are land development regulations that apply to dumpster and compact enclosures not integrated within a principal structure: (a) Location. Dumpster and compact enclosures shall be placed on the side and rear of the property to minimizes their impact on adjacent properties and the surrounding environment. In no event shall the enclosure be less than 25 feet from a residential structure. (b) Size and Capacity. Each enclosure shall provide sufficient clear space between each side of each dumpster (including lifting flanges) and the adjacent surface of that enclosure or other containers within that same enclosure to properly service the container. The height of each enclosure shall be 12 inches greater than the highest part of any dumpster or container therein. The size and capacity of dumpster and compact enclosures must be appropriate for the waste and recycling needs of the site as approved by the Public Works department. (c) Design. Dumpster, compactor, and mechanical equipment enclosures shall have a concrete slab, shall be composed of a finished masonry wall with colors and trim details to match the principal building color, and shall be designed with gates composed of opaque materials, such as PVC or prefabricated metal, painted in an approved color; wood and chain-link gates with or without slats are prohibited. (d) Landscaping. All dumpsters and trash handling areas shall have hedges planted on the outside of the walls which do not have the gated opening, as well as trees, whenever feasible. (e) Screening. Dumpster and compact enclosures must be screened from view from adjacent properties and public rights-of-way, using fencing, walls, or other appropriate means as approved by the Community Appearance Board. (f) Maintenance. Dumpster and compact enclosures must be maintained in a clean and orderly manner, free from overflowing waste and litter, and must be properly secured to prevent unauthorized access. (g) Access. Adequate access for waste collection and removal must be provided, and the enclosure must be designed to minimize the impact of waste collection and removal on adjacent properties and the surrounding environment. Access to indoor or outdoor collection stations shall be such that the removal vehicle need not make unnecessary turning or backing movements. (h) Drainage. The design of dumpster and compact enclosures must include provisions for proper drainage to prevent the buildup of water and to minimize the impact of stormwater runoff on adjacent properties and the surrounding environment. (i) Building Integration. Dumpster enclosure or compactor that are integrated with a primary structure are exempt from the setback and design standards of this section. Community Appearance Board approval shall still be required for the principal structure. (j) Compliance with Health and Safety Regulations. Dumpster and compact enclosures must comply with all applicable local, state, and federal health and safety regulations, including regulations related to fire safety, hazardous waste storage, and air quality. 505.8 Fences and Walls. (a) Fences on residential lots. Fences on a residential lot shall be limited to six feet in height. Barbed wire and other similar material shall not be permitted on a fence or wall within a residential district. Only pressure treated pine, redwood, cypress, black locust and cedar wood shall be acceptable for wood fence construction. All wood fencing shall have a nominal thickness of one inch. A fence or wall may be permitted within a required front yard only within the Rural (RL), Estate (E), and Residential Single-family 1 (RS1) zoning districts and not to exceed a height of six feet subject to the requirements of the clear sight triangles contained in this Code. (b) Residential parcel perimeter and entry walls. Uniform walls may be erected within a required bufferyard and at the access driveway entrances to residential development parcels. The wall shall be located at the interior edge of a bufferyard. Typical elevations, materials and the location of the wall shall be shown on a final site plan. Barbed wire and other similar material shall not be permitted. Walls shall be designed to discourage graffiti. (c) Walls and fences on non-residential parcels. Walls shall be permitted within a required bufferyard at the perimeter of non-residential parcels, they shall not be permitted within a required front yard. Fences within non-residential zoning districts adjacent to residential property shall not exceed eight feet in height. Fences and walls within non-residential property adjacent to non-residential property shall not exceed ten feet in height. Barbed wire and other similar material may be placed on a fence which secures a storage or freight area; however, this material shall not be permitted at the perimeter of a property visible from a right-of-way. Typical elevations, materials and the location of the fence shall be shown on a final site plan. (d) Fences within easements. Fences, walls and landscaping shall not be permitted within a utility easement prior to the issuance of a permit. To locate a fence or wall in any easement an encroachment agreement shall be required. Said encroachment agreement shall only apply to properties platted after January 1, 1996. If a permit is issued, access to any easements shall be granted when required by any utility. A utility company or franchise shall not be responsible for damage to a fence, wall or landscaping within an easement. (e) Maintenance. Fence or wall shall be finished and maintained in good condition and appearance. The finished side of all shadowbox and stockade fences shall face outward to the abutting property or right-of-way; exceptions may be granted for the side and rear yard portions of the fence, which are not facing a right-of-way, if there is an existing fence on the adjacent property. 505.9 Pergolas and Gazebos. Pergolas, trellises, and similar structures that have the ability to open and close the roof, whether it be manual or mechanical, and whether its freestanding or attached to the main structure, shall be regulated as a Gazebo consistent with the requirements of Table 505-1. Overhangs may not encroach any more than two (2) feet into the required structural setback and in no case extend past the property line. Pergolas and Gazebos for non-residential and multifamily developments with four (4) or more dwelling units shall be exempt from the area requirements of Table 505-1. 505.10 Play equipment. Play equipment shall be permitted in any residential district, subject to the following: (a) No permanently installed play equipment, except basketball hoops, shall be permitted within the front setback, ten feet of a right-of-way, or within utility, drainage or access easements. (b) No play equipment shall use street right-of-way as part of playing area. (c) Permanently installed play equipment shall be of a common playground type designed for children. (d) All basketball hoops and backboards in front yard areas shall be permitted on the front of the building or on a pole in the driveway only. Basketball poles shall be located no closer than ten feet to any property line. 505.11 Pools and spas. Swimming pools and spas shall be subject to the following: (a) All residential swimming pools (including above-ground pools and spas which exceed 24 inches in height) must meet all setback requirements as provided in Table 505-1. (b) Any pool for a non-residential development shall meet the structural setbacks for the district in which it is located, and all required governmental agency standards. (c) Safety barrier required, specifications. Swimming pools shall be required to have a permanent non removable safety barrier as provided in this section in addition to the Florida Building Code, as amended from time to time. i. Specifications. No swimming pool final inspection and approval shall be given by the Building, Planning & Zoning department unless there has been erected a safety barrier. The safety barrier shall take the form of a screened-in patio, a fence, a concrete block wall or other method as deemed appropriate by the city's building official. The minimum height of the safety barrier shall be not less than four (4) feet. The safety barrier shall be erected either around the swimming pool or around the premises on which the swimming pool is erected; in either event, it shall enclose the area entirely, prohibiting unrestrained admittance to the enclosed area. Gates shall be of the spring lock type, so that they shall automatically be in a closed position at all times. Gates shall also be equipped with a self-latching lock and shall be locked when the swimming pool is not in use. Water bodies including, but not limited to, lakes and canals may not be considered or utilize as a safety barrier. Other safety requirements may apply based on the current Florida Building Code. ii. Permits required. Before any work is commenced, permits shall be secured for all swimming pools and for the safety barriers. Plans shall contain all details necessary to show compliance with the terms and conditions of these regulations. No swimming pool permit shall be issued unless simultaneously therewith a permit is secured for the erection of the required safety barrier; if the premises are already enclosed, as herein before provided, a permit for the safety barrier shall not be required, if, upon inspection of the premises, the existing barrier is proven to be satisfactory. iii. Construction specifications of walls and fences. In the wooden type fence, the boards, pickets, louvers, or other such members, shall be spaced, constructed, and erected, so as to make the fence non-climbable and impenetrable. Walls, whether of the rock or block type, shall be so erected to make them non-climbable. iv. Authority to disapprove barriers. It shall be within the discretion of the building inspector to refuse approval of any barrier which does not furnish the safety requirements of this regulation, i.e., that it is high enough and so constructed to keep the children of pre-school age from getting over or through it. v. Maintenance of safety barrier; duty of owner, occupant. It shall be the responsibility of the owner and/or occupant of the premises containing the swimming pool to maintain and keep in proper and safe condition at all times the safety barrier required and erected in accordance with this article. vi. Maintenance of pool; duty of owner, occupant. It shall be the responsibility of the owner and/or occupant of the premises containing a swimming pool to keep such pool from becoming a health hazard to the community by becoming a breeding ground for mosquitoes, or by any other means. In the event any person owning or occupying the premises containing a swimming pool permits the safety barrier to become in an improper and unsafe condition, or permits the swimming pool to become a health hazard to the community, the city may direct a letter by certified mail to the owner or occupant of such premises, advising such owner or occupant that the city will have such safety barrier put in a proper and safe condition or correct the health hazard of the swimming pool within a period of ten days from receipt of such letter. The city shall be authorized to place a lien on the property not in compliance with this section in order to recover the costs associated with enforcement of this section. vii. Temporary fence to enclose swimming pools while under construction. No person shall construct or cause to be constructed any swimming pools unless such swimming pool is completely enclosed by a fence with a minimum height of not less than four (4) feet. Such fence may be of a temporary nature but in lieu of a permanent fence, a temporary fence must be erected either around the swimming pool or around the premises on which the swimming pool is under construction; in either event, it shall enclose the area entirely, prohibiting unrestrained admittance to the enclosed area. However, the swimming pool need not be completely enclosed during those periods when an adult person is present on the site and actual construction is in process. This section shall only affect those pools under construction within 140 feet of any residence upon which a certificate of occupancy has been issued. The 140 feet shall be measured from the edge of the swimming pool to the closest property line containing such residence by straight line measure. viii. Utilization of adjacent fencing and other similar barriers. A property owner may elect to use an existing neighboring fence as part of their swimming pool safety barrier, provided the following requirements are met: i. The fence/barrier must be at least four feet in height and shall not have any gaps, holes, or openings larger than four inches in any dimension, with a self-latching gate. ii. The owner of the pool utilizing a neighboring fence as a safety barrier shall execute a restrictive covenant, recorded in the Broward County Public Records, indicating in the event that the adjacent barrier is damaged or removed, the owner of the pool shall replace the barrier within 30 days to ensure that the replacement barrier continues to comply with the requirements of this section. iii. The swimming pool safety barrier, including any portion that is part of a neighboring fence, shall be subject to inspection by the building inspector to ensure that it meets the requirements of this section. 505.12 Rooftop Photovoltaic Solar Systems. (a) Intent. The provisions contained herein are intended to promote the health, safety, and general welfare of the citizens by removing barriers to the installation of alternative energy systems and encourage the installation of rooftop photovoltaic solar systems pursuant to the U.S. Department of Energy Rooftop Solar Challenge Agreement Number DE-EE0005701 ("Go SOLAR—Broward Rooftop Solar Challenge") on buildings and structures within municipal limits. The provisions and exceptions contained herein are limited to rooftop photovoltaic solar systems permitted through web-based applications for pre-approved rooftop photovoltaic solar system installations that utilize the Go SOLAR-Broward Rooftop Solar Challenge permitting process. (b) Permitted accessory equipment. Rooftop photovoltaic solar systems installed pursuant to this subsection shall be deemed permitted accessory equipment to residential and commercial conforming and nonconforming buildings and structures in all zoning categories. Nothing contained in this Land Development Code, including design standards or guidelines included or referenced herein, shall be deemed to prohibit the installation of such rooftop photovoltaic solar systems as accessory equipment to conforming and nonconforming buildings, including buildings containing nonconforming uses. (c) Height. In order to be deemed permitted accessory equipment, the height of rooftop photovoltaic solar systems shall not exceed the roof line, as defined in Chapter 2. For flat roofs with or without a parapet, in order to be deemed accessory equipment, the rooftop photovoltaic solar system shall not be greater than five feet above the roof. (d) Permits. Prior to the issuance of a permit, the property owner(s) must acknowledge, as part of the permit application, that: i. If the property is located in a homeowners' association, condominium association, or otherwise subject to restrictive covenants, the property may be subject to additional regulations or requirements despite the issuance of a permit by the city; and ii. The issuance of said permit for a rooftop photovoltaic solar system does not create in the property owner(s), its, his, her, or their successors and assigns in title, or create in the property itself a right to remain free of shadows and/or obstructions to solar energy caused by development adjoining on other property or the growth of any trees or vegetation on other property or the right to prohibit the development on or growth of any trees or vegetation on another property. (e) Tree maintenance and removal. To the extent that the city has discretion regarding the removal or relocation of trees, solar access shall be a factor taken into consideration when determining whether and where trees may be removed or relocated. (f) Maintenance. The rooftop photovoltaic solar system shall be properly maintained and be kept free from hazards, including, but not limited to, faulty wiring, loose fastenings, being in an unsafe condition or detrimental to public health, safety, or general welfare. 505.13 Utility/Mechanical Equipment. Utility and mechanical used for a building's operation which is located outside the building shall only be located in a rear or side yard. The equipment shall not be located within a utility easement unless it is equipment serving that specific easement. All equipment shall be screened from view by landscape materials as provided for in this Code. These requirements shall not apply to municipal or franchise utilities such as power, phone, cable, communication or drainage equipment which is located within a public utility easement.

(Ord. No. 24-02, §§ 4(Exh. C), 5(Exh. D), 11-1-23)

Ask a question about Miramar law

Corpus searches the Miramar sections it holds and shows the ones that match, with their citations. Free, no sign-in.