Sec. 9-68. - Installation of approved smoke detectors.
(a) Existing occupancy with approved smoke detector. Any existing occupancy in which approved smoke detectors were installed prior to the effective date of the ordinance from which this section was derived may continue such use. (b) Existing occupancy with approved smoke detector. Any existing occupancy in which approved smoke detectors have not been installed prior to the effective date of this section shall have installed approved smoke detectors as follows: (1) Electric powered detectors shall meet the following requirements: a. Approved smoke detectors utilizing AC primary source of electric power shall be used. b. Electrical power shall be a dependable commercial light and power supply source. A visible "power on" indicator shall be provided. c. A restraining means shall be used at the plug-in of any cord-connected installation. d. No detector shall be subject to loss of power by a wall switch. e. Neither loss nor restoration of primary power shall cause an alarm signal. f. No extension cord shall be used for a cord-connected installation. (2) Battery powered detectors shall meet the following requirements: a. All power requirements are met for at least one-year's life, including weekly testing. b. A distinctive audible trouble signal is given before the battery is incapable of operating the devices for alarm purposes. c. The unit is capable of producing an alarm signal for at least four (4) minutes at the battery voltage at which a trouble signal is normally obtained, followed by seven (7) days of trouble signal operation. d. The audible trouble signal is produced at least once every minute for seven (7) consecutive days. e. The monitored batteries meeting these specifications are clearly identified on the unit near the battery compartment. f. Detectors having a test button in order to test the unit are desirable. (c) Additions. When additions increasing floor area are made to an existing occupancy listed and the area of the addition is twenty-five (25) percent or more of the area of the existing occupancy, the existing occupancy and the addition shall be made to comply with subsection (f) below. (d) Repairs and alterations. When repairs and alterations amounting to more than fifty (50) percent of the value of the existing occupancy are made during any twelve-month period, the occupancy shall be made to conform to subsection (f) below. (e) Change of occupancy. Any existing occupancy not included in section 9-67 of this chapter which changes its occupancy to an occupancy included in section 9-67 shall be required to conform to subsection (f) below. (f) New occupancy. Any new occupancy to which this article applies shall install approved smoke detectors as follows: (1) Location shall be approved by the fire marshal. (2) Shall meet the requirements of subsections (b)(1)a, b, d, e above. (3) Detectors shall be installed on a separate electrical circuit, used for no purpose other than detectors, such circuit being connected to the electrical service wires ahead of a circuit breaker or fuses controlling the normal electrical supply to the occupancy. (4) All the installations shall meet the requirements of NFPA 74, 1988 edition, or amendments thereto.
(Code 1964, § 10-42)
Ask a question about Miramar law
Corpus searches the Miramar sections it holds and shows the ones that match, with their citations. Free, no sign-in.