§ 174.042 FUEL, PROPANE, AND NATURAL GAS DISPENSARIES.
Automotive fuel, propane, and natural gas dispensaries and refueling stations, where permitted per § 173.021, shall meet the following provisions: (A) All pumps, storage tanks and other service island equipment shall be at least twenty (20) feet from all property lines, fifteen (15) feet from any building and one hundred (100) feet from the nearest residentially owned land. No pump, storage tank or other equipment shall be located closer than one thousand (1,000) feet from any municipal or public supply well. (B) Liquid gasoline, liquid kerosene, or liquid diesel fuels may be stored onsite for use by the operator of the property and stored onsite for offsite delivery to the general public, and stored, dispensed, and sold onsite to the general public for onsite sales of such substances. (C) Liquid and non-liquid propane, and liquid and non-liquid natural gas and other petroleum-based fuel products (including liquid gasoline, liquid kerosene, or liquid diesel fuel) may be stored onsite for the use of the operator of the property, stored and sold onsite for offsite delivery to the general public, and stored, dispensed, and sold onsite to the general property. (D) The proposed use will not constitute a nuisance or hazard because of vehicular travel movement, delivery of fuel movement, noise or fume generation. (E) Development and operation of the fuel pumps and attendant storage tanks shall be in compliance with the following to protect groundwater and surface water quality from the discharge of fuels from underground fuel storage tanks: (1) All storage tanks and associated piping installed, repaired or modified after the effective date of these regulations shall be designed, constructed, tested and monitored to prevent or detect discharges of all gasoline, diesel, kerosene or other petroleum derivatives to the land, groundwaters or surface waters of the city in accordance with the requirements and standards of this chapter. (2) Inventory records on forms provided by the city shall be maintained for all underground fuel storage tanks including: (a) Fuel type; (b) Physical measure of fuel; (c) Input and output of fuel; (d) Amount of water, if any, in tank; (e) Reconciliation of the above; (f) Reconciliation with previous closing physical inventory. (3) Inventory data shall be accumulated for each day fuel is added or withdrawn from tank, but not less frequently than once a week, and shall be available for inspection by the city at the facility. (4) For the purpose of this chapter, AVERAGE UNACCOUNTED OUTPUT shall mean an amount of fuel which cannot be accounted for after reconciliation of the physical inventory and input and output records. (5) All new tanks installed for the underground storage of fuels shall be designed and constructed to meet the following standards: (a) Cathodically-protected steel meeting the specifications in API 1632, sandblasted to SSPC6, and coated according to NACE RP-01-69. A sacrificial anode tank shall meet the requirements of ULC 603.1-M-1982 and be electrically isolated; (b) Glass fiber-reinforced plastic meeting ASTM Specification D4021-81 and be UL labeled "Nonmetallic Underground Tank for Petroleum Products"; (c) Glass fiber-reinforced plastic clad steel tank sandblasted to SSPC6 with resin and fiberglass one hundred (100) mils thick; or (d) Double-walled steel or plastic tank. (6) All associated piping systems shall be constructed of corrosion-resistant materials or protected against corrosion by the use of double-walled piping or cathodic protection. (7) Tank and piping specifications shall be provided to ensure construction and design is appropriate for intended use. (8) System monitoring. (a) All underground storage tanks and piping shall be provided with a means of monitoring for any leakage of the stored fuel. Such monitoring system shall consist of: 1. A continuous leak detection system between the walls of double-walled tanks and piping; 2. A single monitoring well or detector located in an impervious secondary containment; or 3. A network of at least four (4) monitoring wells placed around the tank or tanks. (b) All leak detection systems and devices shall be installed, maintained, and operated in accordance with manufacturer's requirements and inspected every two (2) weeks to determine that the device is functioning. All wells shall be either monitored every two (2) weeks or be equipped with a continuously functioning leak detection device. (9) System testing. (a) The owner or operator of a fuel storage system shall test the integrity of the storage tank and piping by type, according to the following: 1. A sacrificial anode-type tank shall have structure to soil potential tested annually in accordance with manufacturer's requirements. 2. An impressed current tank shall be tested monthly in accordance with manufacturer's requirements. 3. A glass fiber-reinforced plastic tank shall be tested for deflection at the time of installation in accordance with manufacturer's requirements. (b) All systems shall also be tested if: 1. The operator of the storage system has failed to comply with the inventory requirements; 2. A discharge detection device or monitoring well indicates that the contents of the system has been or is being discharged; 3. Groundwater contamination by fuels exists in the vicinity; or 4. The average unaccounted physical inventory output exceeds one-half of one percent (0.5%) of total monthly output. (c) Such tests shall be conducted by a person trained and certified by the manufacturer of the test equipment or his agent. (d) If for any reason testing cannot be performed in accordance with the above, the tank shall be deemed to be abandoned. (10) When an underground storage tank is found to be leaking, the operator shall empty the tank of all free liquid or otherwise contain the leak within twenty-four (24) hours from testing. (11) No person shall operate or put back into service any underground tank which has leaked or has otherwise failed the testing without having repairs performed in a manner which restores the structural integrity of the tank and piping and having the tank retested. (12) Abandoned fuel storage systems. (a) Any fuel storage system which has been abandoned or has not been in service for over three (3) years shall be removed or filled with sand, concrete or other inert material. (b) No person shall place or store any fuels in an abandoned storage system. (c) No abandoned storage system shall be used or put into service unless the system meets the construction, monitoring, testing and detection requirements of this chapter. (13) All records of testing, inspections, monitoring and inventory required by this chapter shall be maintained for a two (2) year period and be made available to the city for inspection. (Ord. 2024-33, passed 9-19-24)
Ask a question about Palm Bay law
Corpus searches the Palm Bay sections it holds and shows the ones that match, with their citations. Free, no sign-in.