§ 152.092 NON-ELEVATED ACCESSORY STRUCTURES.

Accessory structures are permitted below elevations required by the Florida Building Code provided the accessory structures are used only for parking or storage and: (A) Are one-story and not larger than 600 sq. ft. (B) Have flood openings in accordance with § R322.2 of the Florida Building Code, Residential. (C) Are anchored to resist flotation, collapse or lateral movement resulting from flood loads. (D) Have flood damage-resistant materials used below the base flood elevation plus one foot. (E) Have mechanical, plumbing and electrical systems, including plumbing fixtures, elevated to or above the base flood elevation plus one foot. (Ord. 2001, passed 12-14-22)