VII-1004 — Smoke and other particulate matter

Sarasota Code of Ordinances (Supplement33; through Ordinance26-5592, adopted April20,2026); partial · Sarasota Zoning Code § VII-1004

Corpus is an independent public-information project, not the official City of Sarasota website. Stable reference: corpuslaw.us/code/b77f69f3-a7fb-48d3-b349-807aaa7e6340

Sec. VII-1004. - Smoke and other particulate matter.

(a)

Method of measurement of smoke. For the purpose of grading the density of emission of smoke, the Ringelmann Chart shall be employed. For the purpose of determining smoke units, the Ringelmann density reading shall be made at least once every minute during the period of observation. Each reading (Ringelmann number) shall be multiplied by the time in minutes for which it was observed and the products added together to give the total number of smoke units observed during the total period of observation, which shall be no less than one hour. The total shall then be converted into units per hour. The same method shall be used for all districts.

(b)

Maximum permitted emission of smoke. In all districts, the emission of more than ten smoke units per hour per stack and smoke with a density in excess of Ringelmann No. 2 is prohibited except as indicated below. For special operations in districts where such operations are permitted, the following limitations apply:

(c)

Maximum frequency and permitted smoke units and densities for special operations.

(1)

Maximum frequency permitted:

For rebuilding fires within 24 hour period .....Once

For banking or cleaning fires, soot blowing or process purging .....Once in six hours

(2)

Maximum smoke units permitted per hour per stack during special operations.

Ringelmann No. 1 .....20

Ringelmann No. 2 .....10

Ringelmann No. 3 .....3

(d)

Measurement of emission of particulate matter. Determination of the total net rate of emission of particulate matter within the boundaries of all zoning lots shall be made as follows:

(1)

Determine maximum emission in pounds per hour from each source of emission and divide this figure by acres of zoning lot area, obtaining the gross hourly rate of emission in pounds per acre.

(2)

For each gross hourly rate of emission, deduct the height of emission correction factor from the following table, interpolating as necessary for heights not given.

Allowance for Height of Emission

| | | | --- | --- | | Height of emission above grade (feet) | Correction (pounds per hour per acre) | | 50 | 0.01 | | 100 | 0.06 | | 150 | 0.10 | | 200 | 0.16 | | 300 | 0.30 | | 400 | 0.50 |

The result is the net hourly rate of emission in pounds per acre from each source of emission.

(3)

Adding together individual net rates of emission gives the total net rates of emission from all sources of emission within the boundaries of the zoning lot.

(e)

Maximum permitted emission of particulate matter. The total net rate of emission from all sources within the boundaries of any zoning lot shall not exceed 75 micrograms per cubic meter of air at the zoning lot line. From all sources within any zoning lot area, emission of particulate matter containing more than ten percent by weight of particles having a diameter of more than 44 microns is prohibited. Dust and other types of air pollution carried by wind from storage yards, piled materials, yards, roads, etc., within the zoning lot shall be included in particulate-matter measurements and limitations and shall in any case be kept to a minimum by appropriate screening, design landscaping, paving, oiling, sprinkling or other acceptable means.

(Ord. No. 02-4357, 4-29-02)