For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

VII-1304 — Seawall, groins and beach protective devices

Sarasota Code of Ordinances (Supplement33; through Ordinance26-5592, adopted April20,2026); partial · Sarasota Zoning Code § VII-1304

Corpus is an independent public-information project, not the official City of Sarasota website. Stable reference: corpuslaw.us/code/1e22a82d-db5f-40b7-8814-82c85b0f7082

Sec. VII-1304. - Seawall, groins and beach protective devices.

(a)

All seawalls, groins, and beach protection devices must be properly designed to prevent erosion of the property on which they are erected and to not adversely affect adjacent and nearby properties. In no event shall the top of such protective devices exceed an elevation of 7.27 ft. - NAVD88. In the event the city engineer has reason to believe that the proposed elevation would create adverse impacts on adjacent or nearby properties, the city engineer shall be authorized to limit the maximum elevation of the structure to an elevation that is less than the maximum authorized by this subsection. Applicants shall be required to provide professionally certified construction plans to demonstrate that the proposed elevation of the seawall or bulkhead will not create adverse impacts on neighboring properties. If adverse impacts on adjacent and nearby properties, as determined by the city engineer, occur subsequent to approval of the structure, then it is the responsibility of the property owner who installed the structure to rectify in accordance with written notification from the city engineer. Property owners are encouraged to consider approaches and materials that enhance the biological value of traditional (flat surface) seawalls and flood barriers with the incorporation of living shoreline features, use of hybrid green-grey materials, and the use of biological forms, where practicable. Seawalls, groins, bulkheads, and beach protective devices constructed on public or private property shall be designed to conform to the standards specified in the Engineering Design Criteria Manual (EDCM).

(b)

Where properties are located on the waters of the Gulf or the waters of passes, seawalls, groins and other beach protection devices or coastal armoring shall be erected in accordance with F.S. § 161.085 and only upon approval of the city commission at a public hearing held for such purpose. At the public hearing, the applicant shall demonstrate that:

(1)

Such beach protection works are necessary to prevent such erosion;

(2)

Are properly designed to prevent erosion of the property on which they are to be erected; and

(3)

Will not adversely affect adjacent and nearby properties.

(c)

Where properties are located on any shoreline other than as described in subsection (b) above, the city engineer shall review the application for a permit and supporting materials and make a written determination as to whether the application satisfies the three criteria specified in subsection (b) above. Seawalls and bulkheads permitted in accordance with this subsection may be erected only landward of mean highwater lines.

(d)

Seawalls, groins, and beach protective devices that are seaward of the mean highwater line that existed on November 2, 2009, may be repaired or replaced to the same extent that existed on that date. Seawalls may be repaired with panels seaward of the seawall if it is determined by the director of development services that such panel is the appropriate method of repair.