VII-1402 — Site lighting
Sarasota Code of Ordinances (Supplement33; through Ordinance26-5592, adopted April20,2026); partial · Sarasota Zoning Code § VII-1402
Corpus is an independent public-information project, not the official City of Sarasota website. Stable reference: corpuslaw.us/code/4a8f8a12-6885-4147-ba6e-5550499f464a
Sec. VII-1402. - Site lighting.
(a)
Purpose and intent. Nonresidential and residential buildings and projects, including their out parcels, shall be designed to provide safe, convenient, and efficient lighting for pedestrians and vehicles. Lighting shall be designed in a consistent and coordinated manner for the entire site. The lighting and lighting fixtures shall be integrated and designed so as to enhance the visual impact of the project on the community and/or should be designed to blend into the surrounding landscape. Lighting design and installation shall ensure that lighting accomplishes on-site lighting needs without intrusion on adjacent properties.
(b)
Applicability.
(1)
New development. These regulations shall apply to all new nonresidential or multiple-family development. A site lighting plan shall be required to demonstrate compliance with these regulations.
(2)
Expansion and remodeling. These regulations shall apply to any expansion or remodeling of existing non-residential or multiple family development that exceeds 50 percent of the structures' assessed valuation. A site lighting plan shall be required to demonstrate compliance with these regulations. Assessed valuation shall be determined by reference to the official property tax assessment rolls of the year the structure(s) is to be remodeled.
(3)
Repair and maintenance. These regulations shall apply to replacement of 50 percent or more of the existing lighting fixtures in any nonresidential or multiple-family development.
(4)
Turtle protection. The site lighting requirements in this section shall not supersede the requirements of article XXIII of the County Code, marine turtle protection (formerly known as Sarasota County Ordinance No. 97-082 which has been adopted by reference in City of Sarasota Resolution No. 05R-1832).
(c)
Site lighting design requirements.
(1)
Fixtures (luminaires). The light source shall be completely concealed within an opaque housing on all sides except for the bottom of the fixture where illumination exits the fixture and shall not be visible from any street right-of-way or adjacent properties. All fixtures shall be full cut-off fixtures.

Fixture Height
(2)
Fixture and pole height. Lighting fixtures and poles shall be a maximum of 30 feet in height within the parking lot and shall be a maximum of 15 feet in height within non-vehicular pedestrian areas. Lighting for recreational facilities related to schools and parks shall be exempt from this requirement unless the poles are within 100 feet of residentially zoned property. Bollard lighting shall be a maximum of 42" in height.
(3)
Light source (lamp). Only incandescent, fluorescent, metal halide, single-color light emitting diode (LED), or color-corrected high-pressure sodium may be used. The same light source type must be used for the same or similar types of lighting on any one site throughout any development.
(4)
Mounting. Fixtures shall be full cut-off type and mounted in such a manner that the cone of light is primarily directed towards the earth's surface or otherwise shielded, such that lighting is primarily contained on-site. Lighting levels at the property line shall not exceed the value in subsection (d)(2) below.
(5)
Limit lighting to periods of activity. The use of sensor technologies, timers or other means to activate lighting during times when it will be needed may be required by the director of development services to conserve energy, provide safety, and promote compatibility between different land uses.
(6)
Illumination levels.
a.
All site lighting shall be designed so that the level of illumination as measured in footcandles at any one point meets the standards in the table below or meet the NFPA 101 Life Safety Code requirements (7.8.1.3) for egress lighting of stairs and ADA ramps. Lighting levels up to 25 percent higher may be allowed by the director of development services subject to the applicant demonstrating that higher lighting levels are necessary to meet objectives for environmental programs such as Crime Prevention Through Environmental Design (CPTED) and Leadership in Energy and Environmental Design (LEED) and will not conflict with subsection (d) concerning excessive illumination below:
Exterior Lighting and Parking Lots

Nonresidential and Multi-family Residential Parking Garages

b.
Minimum and maximum levels are measured on the pavement within the lighted area.
c.
Lighting for automated teller machines (ATMs) shall be required to meet the standards of F.S. § 655.962.
(d)
Excessive illumination for nonresidential or residential lots.
(1)
Lighting within any lot that unnecessarily illuminates and substantially interferes with the use or enjoyment of any other lot, or which unnecessarily illuminates the night sky is prohibited. Lighting unnecessarily illuminates another lot if it clearly exceeds the requirements of this section. Lighting unnecessarily illuminates the night sky if it directly projects into the night sky or if it clearly exceeds average lighting levels when measured at a height above the lighting fixture or its shield.
(2)
All outdoor lighting shall be designed and located such that the maximum illumination measured in footcandles at the property line does not exceed 0.5 on adjacent residential sites, and 1.0 on adjacent commercial sites and public rights-of-way.
(3)
Lighting shall not be oriented so as to direct glare or excessive illumination onto streets in a manner that may distract or interfere with the vision of drivers on such streets.
(4)
Fixtures used to accent architectural features, landscaping or art shall be located, aimed or shielded to minimize light spill into the night sky.
(5)
Illumination using illuminated tubing or strings of lights that outline or define 50 percent or more of property lines, sales areas, roofs, doors, windows, or similar areas in a manner that is not primarily for safety purposes, as determined by the director of development services, is prohibited. However, this shall not be construed to preclude holiday/seasonal light displays.
(Ord. No. 02-4357, 4-29-02; Ord. No. 03-4473, § 5, 6-16-03; Ord. No. 06-4682, § 2, 7-26-06; Ord. No. 07-4770, § 2, 12-17-07; Ord. No. 09-4838, § 2(att. 1), 2-17-09; Ord. No. 10-4927, § 2(att. 1), 2-22-11; Ord. No. 21-5364, § 2(Exh. A), 5-18-21; Ord. No. 24-5540, § 2(Exh. A), 9-16-24)