For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 16.20.010.6 — Building envelope: Maximum height and minimum setbacks

Code of Ordinances, City of St. Petersburg, Florida (Supp. No. 55, Update 2: codified through Ordinance No. 646-H, adopted August 27, 2026) · St. Petersburg City Code § 16.20.010.6

Corpus is an independent public-information project, not the official City of St. Petersburg website. Stable reference: corpuslaw.us/code/270608c1-bb77-4e03-b1d8-e92313d25294

16.20.010.6. - Building envelope: Maximum height and minimum setbacks.

Building Height | Beginning of Roofline | Top of Roof Peak Primary building | 24 ft. | 36 ft. Accessory building | 20 ft. | 30 ft. Refer to technical standards regarding measurement of building height and height encroachments. [image omitted; see the official code] Minimum Building Setbacks Building Setbacks | NT-1 and 2 | NT-3 | NT-4 If beginning of roof line is less than or equal to 18 ft. | If beginning of roof line is greater than 18 ft. up to 24 ft. | If beginning of roof line is greater than 24 ft. | If beginning of roof line is less than or equal to 24 ft. | If beginning of roof line is greater than 24 ft. | If beginning of roof line is up to 24 ft. | If beginning of roof line is greater than 24 ft. Front yard | Stoop | 15 ft. or M | 15 ft. or M | 35 ft. | 20 ft. or M | 40 ft. | 9 ft. or M | 28 ft. Open Porch (1) | 18 ft. or M | 18 ft. or M | 35 ft. | 23 ft. or M | 40 ft. | 12 ft. or M | 28 ft. Building | 25 ft. or M | 25 ft. or M | 35 ft. | 30 ft. or M | 40 ft. | 18 ft. or M | 28 ft. Interior side yard | For lots greater than 60 ft. in width | 6 ft. or M | 6 ft. or M | 12 ft. | 7.5 ft. or M | 16 ft. | 5 ft. or M | 10 ft. For lots equal to or less than 60 ft. in width | 10 percent of lot width (2) or M | 6 ft. or M | 12 ft. | 7.5 ft. or M | 16 ft. | 5 ft. or M | 10 ft. Street side yard | 12 ft. or M | 12 ft. or M | 16 ft. | 15 ft. or M | 22 ft. | eight ft. or M | 15 ft. Rear yard, with alley | For alleys equal to or greater than 16 ft. in width | 6 ft. or M | 6 ft. or M | 20 ft. | 6 ft. or M | 20 ft. | 5 ft. or M | 20 ft. For alleys less than 16 ft. in width | 10 ft., or 22 ft. including the width of the alley, whichever is less, or M | 10 ft., or 22 ft. including the width of the alley, whichever is less, or M | 20 ft. | 10 ft., or 22 ft. including the width of the alley, whichever is less, or M | 20 ft. | 8 ft., or 22 ft. including the width of the alley, whichever is less, or M | 20 ft. Rear yard, no alley | 10 ft. or M | 10 ft. or M | 30 ft. | 10 ft. or M | 30 ft. | 10 ft. or M | 30 ft. Waterfront yard | 20 ft. | 20 ft. | 20 ft. | 20 ft. | 20 ft. | 20 ft. ft. | 20 ft. Notes: (1) Open porches are limited to a one story covered porch with or without a second story uncovered porch; two story covered porches shall meet the principal structure setback. (2) For properties that are 50 feet or less in width, the minimum side yard building setback shall be five feet. M (minor encroachment): Minor encroachments into normally prescribed setbacks may be allowed in order to accommodate an addition to align with the side of the existing structure, provided: (a) The total floor area of the encroaching portion of an addition shall not exceed 50 square feet; (b) No portion of the encroachment shall exceed 24 feet in height; (c) In no case shall any encroaching structure be closer to a property line than four feet. Refer to the dimensional regulations and lot characteristics and height, maximum allowable and encroachments sections (currently 16.60.010 and 020) for yard types and setback encroachments. For properties located in a Special Flood Hazard Area, encroachments into normally prescribed setbacks may be allowed in order to accommodate an existing single-family home being elevated to meet the required FEMA design flood elevation provided: (a) Any additions to the existing building footprint, stairways or elevated decks must meet the normally prescribed setbacks; and (b) The interior side yard setback shall be a minimum of three feet. Enclosing porches in the front yard setback is regulated by the general development standards. The larger of the minimum building separation distances required by the Florida Building Code or the fire prevention code or the minimum building setback established for the interior side yard setback shall apply. Building setbacks are based on the overall height of the various sections of a proposed building. As the building height increases, so does the minimum required setback. [image omitted; see the official code] Minimum Building Setbacks for SE Uses Building Setbacks SE Uses | NT-1 and 2 | NT-3 | NT-4 All yards (including waterfront) | 35 ft. | 35 ft. | 35 ft. Refer to technical standards for yard types.

(Code 1992, § 16.20.010.6; Ord. No. 876-G, § 2, 2-21-2008; Ord. No. 893-G, § 2, 9-4-2008; Ord. No. 287-H, § 2, 7-20-2017; Ord. No. 611-H, § 3, 7-10-2025)

Ask a question about St. Petersburg law

Corpus searches the St. Petersburg sections it holds and shows the ones that match, with their citations. Free, no sign-in.