Sec. 27-215. - Backflow preventer criteria.
(a) The POD will evaluate the hazards inherent in supplying a customer's water system. If an approved backflow preventer is required at the customer's water service connection or within the customer's water system, the POD shall give written notice to the customer of the specific locations, types and sizes of the required devices. Backflow preventers will be sized to match meter or pipe size at the required location unless otherwise approved by the POD. The cost to install the required backflow prevention assembly shall be recovered through the monthly water rate. (b) When the backflow preventer is to be installed at the water service connection and must be installed on private property, the customer shall also be required to provide an easement or other license agreement for the installation of each backflow preventer. Such easement or license agreement shall not assign any responsibility to the City for the maintenance or repair of any private water system lines, valves or fittings installed within the easement. (c) Failure or refusal or inability on the part of the customer to provide for the installation of required backflow preventers within 90 days shall constitute a ground for discontinuing water service to the premises until such backflow preventers have been properly installed. (d) Wherever the following conditions exist, an approved backflow preventer shall be installed on each service line to a customer's water system at or near the property line or immediately inside the building being served, but in all cases, before the first branch line leading off the service line: (1) In the case of premises having an auxiliary water supply that is not or may not be of safe bacteriological or chemical quality, the water system shall be protected against backflow from the premises by installing an approved backflow preventer in the service line, appropriate to the degree of hazard. (2) In the case of premises on which any industrial fluids or any other objectionable substances are handled in such a fashion as to create an actual or potential hazard to the water system, the water system shall be protected against backflow by installing an approved backflow preventer in the service line, appropriate to the degree of hazard. This requirement shall include the handling of processed waters and waters originating from the water system that have been subject to deterioration in quality. (3) In the case of premises having internal cross connections that cannot be permanently corrected and controlled, or intricate plumbing and piping arrangements or where entry to all portions of the premises is not readily accessible for inspection purposes, making it impracticable or impossible to ascertain whether or not dangerous cross connections exist, the water system shall be protected against backflow from the premises by installing an approved backflow preventer in the service line. (e) The type of backflow preventer required shall depend upon the degree of hazard that exists as determined by the POD as follows: (1) In the case of any premises where there is an auxiliary water supply and it is not subject to any of the following rules, the water system shall be protected by an approved air gap separation or an approved reduced pressure principle backflow preventer. (2) In the case of any premises where there is water or substances that would be objectionable but not hazardous to health, if introduced into the water system, the water system shall be protected by an approved double check valve assembly. (3) In the case of any premises where there is any material dangerous to health that is handled in such a fashion as to create an actual or potential hazard to the water system, the water system shall be protected by an approved air gap separation or an approved reduced pressure principle backflow preventer. Examples of premises where these conditions will exist include, but are not limited to, sewage treatment plants, sewage pumping stations, chemical manufacturing plants, hospitals, mortuaries, and plating plants. (4) In the case of any premises where there are uncontrolled cross connections, either actual or potential, the water system shall be protected by an approved air gap separation or an approved reduced pressure principle backflow preventer at the service connection. (5) In the case of any premises where, because of security requirements or other prohibitions or restrictions, it is impossible or impractical to make a complete in-plant cross connection survey, the water system shall be protected against backflow from the premises by either an approved air gap separation or an approved reduced pressure principle backflow preventer on each service. (6) In the case of any premises where, in the opinion of the POD, an undue health threat is posed because of the presence of extremely toxic substances, the POD may require an air gap separation at the service connection to protect the water system. (7) In the case of any premises where there is reclaimed water service for irrigation, there shall be no physical connection between the reclaimed water system and the customer's water system which is served by the public water system. Where such connections are found, disconnections shall be accomplished, and the water system shall be protected against the possibility of future reconnection by a reduced pressure principle backflow preventer at the service connection. A dual check (three-fourths of an inch or one inch) or double check valve assembly (larger services) shall be required at all premises that may be served by reclaimed water. (8) In the case where the metered use of potable water is permitted directly from a fire hydrant or other water system fixture for filling tank type vehicles (i.e., lawn maintenance and pest control), the water system shall be protected by a reduced pressure principle backflow preventer. (9) In the case where temporary use of water is permitted directly from a fire hydrant or other water system fixture through a portable meter (i.e., construction activity), the water system shall be protected by a double check valve assembly. (f) Unless otherwise determined by the POD, based on the criteria set forth in this article, commercial properties using new potable water service of three-quarter inch and greater in size are required to have backflow preventers installed as follows: (1) For low hazard applications requiring a double check valve assembly, the backflow preventer and meter assembly shall be installed below ground level. In addition to the regular backflow installation charges, the customer shall be responsible for all costs associated with the vault or meter box and installation below ground. (2) For high hazard applications requiring an approved air gap or a reduced pressure principle backflow preventer, the backflow preventer shall be installed above ground level in accordance with the State of Florida, Department of Environmental Protection regulations set forth in Chapter 62-555, Florida Administrative Code and the AWWA Manual M-14, Recommended Practice for Backflow Prevention and Cross Connection Control, Third Edition. The cost for the installation of a required backflow preventer shall be paid by the customer prior to installation. (g) Unless otherwise determined by the POD, based on the criteria set forth in this Article, properties which include the installation of a dedicated fire service of any size are required to have a detector check assembly installed below ground in a properly constructed vault or meter box. The customer shall pay the City all costs associated with the vault construction and installation below ground. The customer shall also be responsible for the installation and maintenance of a post indicator valve on the customer water system which meets fire department specifications and NFPA regulations at the customer's own expense. (h) The POD may grant a variance from the terms of this section when such variance will not be contrary to the public interest and where, owing to special conditions, literal enforcement of the provisions of this section would result in a hardship to the applicant. Hardship may include but is not limited to: (1) There is insufficient room for the installation of a backflow preventer in an underground vault due to unique shape of the customer's property. (2) The Customer's existing building is too close to a right of way to allow for installation of an underground vault. (3) The water table is too high at a particular location to allow installation of an underground vault. (4) Existing utilities on or adjacent to the customer's property cannot be relocated to accommodate installation of an underground vault. (5) The customer's property has existing foundation construction or mature trees which precludes installation of an underground vault. Such variance shall not be granted by the POD unless and until a written application for variance has been submitted to POD demonstrating that the variance shall not conflict with any other applicable ordinance or state law and will not adversely affect the potable water supply. In addition, the customer shall agree to provide a suitable alternate location for an above ground meter and backflow preventer in an area that is not visible to the public from the right-of-way. An applicant for variance may appeal the denial of a variance by requesting a hearing before the St. Petersburg City Council. The applicant shall have 15 days from the receipt of notice of the denial of variance to request a hearing. The hearing shall occur as soon as reasonably practical but in no event later than 35 days after receipt of the request for the hearing. The hearing shall provide for adequate due process as constitutionally required in any quasi-judicial proceeding. The City Council may uphold the denial of the variance, overturn the denial and grant the variance or grant the variance with such conditions as it deems necessary to assure compliance with the criteria listed in this section.
(Code 1992, § 27-73; Ord. No. 2090-F, § 1(28-77), 9-19-1991; Ord. No. 109-G, §§ 11, 12, 8-19-1993; Ord. No. 1009-G, § 2, 1-20-2011)
Ask a question about St. Petersburg law
Corpus searches the St. Petersburg sections it holds and shows the ones that match, with their citations. Free, no sign-in.