Sec. 27-334. - Grease traps and interceptors.

(a) Requirements. All food service facilities required to install a grease trap or grease interceptor pursuant to the Florida Building Code shall properly install such equipment in accordance with any and all applicable requirements of the Florida Building Code. (1) New facilities. Food service facilities which are newly proposed or constructed, or existing facilities which will be expanded or renovated to include a food service facility, where such facility did not previously exist, required to install a grease interceptor or grease trap pursuant to the Florida Building Code shall operate and maintain its grease trap or interceptor according to the requirements contained in this division. (2) Existing facilities. Food service facilities shall be permitted to operate and maintain existing grease interceptors or grease traps, provided their grease interceptors or grease traps are in efficient operating condition. The City may require an existing food service facility to install a new grease interceptor or trap that complies with the requirements of the Florida Building Code or to modify or repair any noncompliant plumbing or existing interceptor or trap within 30 days of written notification by the City when any one or more of the following conditions exist: a. The facility is found to be contributing oils and grease in quantities sufficient to cause line stoppages or necessitate increased maintenance on the wastewater collection system. b. The facility does not have a required grease interceptor or trap. c. The facility has an irreparable or defective grease interceptor or trap. d. Remodeling of the food preparation or kitchen waste plumbing system is performed which requires a permit to be issued by the City. e. The facility is sold or undergoes a change of ownership. f. The facility does not have required plumbing connections to a grease interceptor or trap. g. The facility fails to submit a completed application form for a GDP within 30 days after the date of the receipt of an application form by the City. h. The facility has not operated as a food service facility for 12 consecutive months prior to receiving the GDP application form. i. The facility misrepresented information on its application for building permits regarding the use of the facility as a food service facility. (b) Plumbing connections. Grease interceptors or traps shall be installed in accordance with the Florida Building Code which requires that such interceptor or trap be located in the food service facility's lateral sewer line between all fixtures which may introduce grease into the sewer system and the connection to the City's wastewater collection system. Wastewater from sanitary facilities and other similar fixtures shall not be introduced into the grease interceptor or trap under any circumstances. (c) Grease traps. Grease traps required to be installed pursuant to the Florida Building Code shall be installed in accordance with the Florida Building Code and shall meet the following criteria: (1) Flow control device. Grease traps shall be equipped with a device to control the rate of flow through the unit. The rate of flow shall not exceed the manufacturer's rated capacity recommended in gallons per minute for the unit. Each food service facility is responsible for maintaining appropriate flow control devices. (2) Venting. The flow control device and the grease trap shall be vented in accordance with the Florida Building Code. The vent shall terminate not less than six inches above the flood-rim level or in accordance with the manufacturer's instructions. Each food service facility is responsible for maintaining appropriate venting of the grease trap. (3) Inspection, cleaning and maintenance. Each permitted food service facility shall be solely responsible for the cost of trap installation, inspection, cleaning, and maintenance. Each permitted food service facility may contract with a grease hauler who has been permitted by the City for cleaning services or it may develop a written protocol and perform its own grease trap cleaning and maintenance procedures. Cleaning and maintenance must be performed when the total volume of captured grease and solid material displaces more than 25 percent of the total volume of the trap. Each permitted food service facility shall determine the frequency at which their grease trap shall be cleaned, but all grease traps shall be opened, inspected, cleaned, and maintained at a minimum of once per week. (4) Inspection. Grease traps shall be inspected by a GMP Official as necessary to ensure compliance with the GMP and to ensure proper cleaning and maintenance schedules are being adhered to. (5) Repairs and replacement. The permitted food service facility shall be responsible for the cost and scheduling of all repairs or replacement to its grease trap. Repairs or replacement required by a GMP Official shall be completed within 30 calendar days after the date of written notice of required repairs or replacement is received by the facility. The POD may authorize an extension of time to achieve compliance for an additional 60 days. If additional time is necessary to come into compliance, the food service facility may enter into an administrative order establishing a schedule for bringing the food service facility into compliance within 24 months from the date of the original notice. (6) Disposal. Grease and solid materials removed from a grease trap shall be disposed of in the solid waste disposal system. (7) Record keeping. The permitted food service facility shall maintain records of the date and time of all cleaning and maintenance of each grease trap in a bound logbook and shall make this book available for inspection by the GMP Official on demand. The permitted food service facility shall also maintain the written protocol concerning grease trap cleaning and maintenance procedures and shall make this available to the GMP Official on demand. (d) Grease interceptors. Grease interceptors required to be installed pursuant to the Florida Building Code shall be designed and installed in accordance with the Florida Building Code and shall be operated and maintained in accordance with the following criteria: (1) Inspection, pumping and maintenance. Each permitted food service facility shall be responsible for the costs of installing, inspecting, pumping, cleaning, and maintaining its grease interceptor. All permitted food service facilities that have grease interceptors shall utilize a grease hauler who has been permitted by the City for pumping services. Pumping services shall include the initial complete removal of all contents, including floating materials, wastewater, and bottom sludges and solids from the interceptor. The return of gray water back into the grease interceptor from which the wastes were removed is allowable only for food service facilities which have not obtained a variance from the monthly pumping requirement, provided that grease and solids are not returned to the interceptor and further provided that the grease hauler has written authorization from the food service facility to return the gray water. Grease interceptor cleaning shall include scraping excessive solids from the walls, floors, baffles and all pipework. The grease hauler shall wait at least 20 minutes to allow the interceptor waste to separate in the truck tank before attempting to re-introduce the gray water to the interceptor. The volume of gray water returned to the interceptor shall not exceed 75 percent of the volume of the interceptor. It shall be the responsibility of each food service facility to inspect its grease interceptor during the pumping procedure to ensure that the interceptor is properly cleaned out and that all fittings and fixtures inside the interceptor are in working condition and functioning properly. (2) Interceptor pumping frequency. Each permitted food service facility shall have its grease interceptors pumped at a minimum frequency of once every calendar month. There shall be a minimum period of three weeks between each required pumping. In addition to required monthly pumping, each permitted food service facility shall determine an additional frequency at which its grease interceptors shall be pumped according to the following criteria: a. When the floatable grease layer exceeds six inches in depth as measured by an approved dipping method; b. When the settleable solids layer exceeds eight inches in depth as measured by an approved dipping method; c. When the total volume of captured grease and solid material displaces more than 25 percent of the capacity of the interceptor as calculated using an approved dipping method; or d. When the interceptor is not retaining/capturing oils and greases. (3) Variance procedure. If a permitted food service facility determines that monthly pumping of its grease interceptor is unnecessary in order to remain in compliance with the criteria of subsection (d)(2) of this section, the facility may make written application for a variance from the monthly pumping requirements to the City. The variance procedure shall be as follows: a. The food service facility shall submit an application for a variance on a form provided by the City along with the required fee. The application shall include the next date and time the facility intends to have its interceptor pumped and cleaned and an affidavit from the applicant stating that it shall permit no further pumping or cleaning of the interceptor until the City has completed its evaluation and notified the applicant of the appropriate pumping frequency. b. A GMP Official shall inspect the interceptor on the specified date and time during or after the pump-out procedure. c. If the interceptor is in good working condition during the initial inspection, the GMP Official shall re-inspect the interceptor approximately 30 days after the initial inspection. d. After the initial re-inspection, the GMP Official shall inspect the interceptor at intervals of approximately every 14 working days to determine the grease and solids level using a dipping method approved by the City. e. If during re-inspection the level of grease reaches six inches or the level of solids reaches eight inches, the GMP Official shall use the number of days from the initial pumping date to the final re-inspection date as the new pumping frequency requirement to be included in the variance granted. f. If, at a re-inspection, the level of grease exceeds six inches or the level of solids exceeds eight inches, the GMP Official shall use the number of days from the initial pumping date to the previous re-inspection date as the new pumping frequency requirement to be included in the variance granted. g. Where two or more interceptors are located at the same facility on different laterals, one variance application process shall apply to both interceptors and different variances may be determined for each interceptor. h. Where two or more interceptors are connected in series on the same lateral, one variance application process shall apply to both interceptors. The two or more interceptors shall all be initially pumped on the same day and the variance for the first interceptor shall be determined when the grease or solids criteria are reached. The first interceptor shall not be pumped at this time and the variance procedure shall continue to monitor the second interceptor until either the grease or solids criteria are reached. At this time both interceptors must be pumped and the new variances for the first and second interceptors will be issued. i. If there is any evidence that the interceptor has been tampered with or pumped out during the variance procedure, the procedure will be declared null and void and a new application and fee will be required from the food service facility to re-start the procedure. j. The approved variance shall be in force until there is either a change in ownership of the food service facility or extensive remodeling of the kitchen occurs which requires a plumbing permit to be issued. k. In any event, pump-out and cleaning of an interceptor shall be required at least once every 180 days with no return of gray water to the interceptor. l. Failure to provide complete pump-out of interceptor at the required intervals may result in a revocation of the approved variance. (4) Inspection. Grease interceptors shall be inspected by a GMP Official as necessary to ensure compliance with the GMP and to determine if proper cleaning and maintenance schedules are being adhered to. If, upon inspection, an interceptor is found to have six inches or more of grease or eight inches or more of solids, the food service facility shall be required to have the interceptor pumped out within 72 hours of the inspection date. Failure to pump-out the interceptor shall constitute a violation of this division. (5) Repairs and replacement. Each permitted food service facility shall be responsible for the cost and scheduling of all repairs to or replacement of its grease interceptors. Repairs or replacement required by a GMP Official shall be corrected within 30 calendar days after the date of written notice of requiring the repairs or replacement is received by the facility. The POD may authorize an extension of time to achieve compliance for an additional 60 days. If additional time is necessary to come into compliance, the food service facility may enter into an administrative order establishing a schedule for bringing the food service facility into compliance within 24 months from the date of the original notice. (6) Disposal. Wastes removed from each grease interceptor shall be disposed of at a facility permitted to receive such wastes or at a location designated by the City for such purposes. Neither grease nor solid materials removed from interceptors shall be returned to any grease interceptor, private sewer line or to any portion of the sewer system or water reclamation facilities without prior written permission from the POD. (7) Record keeping. Each permitted food service facility shall maintain a logbook in which a record of all interceptor maintenance is entered, including the date and time of the maintenance, details of any repairs required and dates of repair completion and any other records pertaining to the interceptor. This logbook shall be made available for review upon request by the GMP Official. Each food service facility shall also maintain a file on site which contains the following information: a. The as-built drawings of the plumbing system, if available. If as-built drawings are not available, other drawings of sufficient detail to depict the plumbing layout of the food service facility. b. A copy of the current grease disposal permit. c. Copies of quarterly reports. d. Receipts from grease pumpers, plumbers, parts suppliers, etc. e. Log of pumping or cleaning activities. f. Log of maintenance activities. g. Hauler information. The file shall be available at all times for inspection and review by the GMP Official. The failure to maintain complete records or to provide such records to the GMP Official upon request constitutes a violation of this division. (8) Reserved. (e) Additives. Any chemicals, enzymes, emulsifiers, live bacteria or other grease cutters or additives used for purposes of grease reduction shall be approved by the GMP Official prior to their addition to grease traps or grease interceptors by the food service facility or the grease hauler. MSDS sheets and any other applicable information concerning the composition, frequency of use and mode of action of the proposed additive shall be sent to the City together with a written statement outlining the proposed use of the additives. Based upon the information received and any other information solicited from the potential user or supplier, the City shall permit or deny the use of the additive in writing. Permission to use any specific additive may be withdrawn by the City at any time. (f) Alternative grease removal devices or technologies. Alternative devices and technologies such as automatic grease removal systems shall be subject to written approval by the POD prior to installation. Approval of the device shall be based on demonstrated (proven) removal efficiencies and reliability of operation. The POD may approve these types of devices depending on manufacturer's specifications on a case-by-case basis. The food service facility may be required to furnish analytical data demonstrating that grease discharge concentrations to the sewer system will not exceed the limitation established in section 27-307(a)(7). (g) Registered grease haulers. A food service facility may authorize a grease hauler to act on its behalf regarding inspection, disposal, records maintenance, and reporting pursuant to subsections (g)(1), (4), (6), (7), and (8) of this section, provided the grease hauler has registered with the City and meets the following conditions: (1) Grease hauler has completed and submitted a grease program registration form to the department containing the following information: a. List of every food service facility authorizing grease hauler to perform the inspection, disposal, record keeping, and reporting requirements. b. List of all trucks or vehicles used to clean interceptors. c. List of all drivers or personnel used to clean interceptors. d. List of all disposal sites. (2) Grease hauler agrees to maintain all records regarding all maintenance activities for a period of three years and to make such records available for review by the GMP Official. (3) Grease hauler submits quarterly reports detailing interceptor cleaning for each food service facility along with a statement attesting to the accuracy of the information contained in the reports. The report shall include the following information: a. Estimated depth of grease and solids removed from interceptor. b. Any defects in the grease interceptor. c. Date of pump-out and notation of whether or not gray water was returned to the interceptor. d. Capacity of interceptor tank. (4) Grease hauler certifies that grease was disposed of in accordance with the provisions of this division. (h) Use of registered hauler. A food service facility who has authorized a registered grease hauler to act on its behalf is not relieved of its responsibilities pursuant to this division. However, in the event reports are not timely submitted or are incomplete, the GMP Official will attempt to first contact the registered hauler and request that the deficiencies be corrected.

(Code 1992, § 27-227; Ord. No. 538-G, § 1, 6-20-2002; Ord. No. 736-G, § 1, 6-16-2005; Ord. No. 146-H, § 3, 12-18-2014; Ord. No. 595-H, § 22, 9-5-2024)

Ask a question about St. Petersburg law

Corpus searches the St. Petersburg sections it holds and shows the ones that match, with their citations. Free, no sign-in.