§ 5-1-3 — Pretreatment of wastewater
Code of the Unified Government of Athens-Clarke County, Georgia (Supp. No. 48, codified through Ordinance of May 5, 2026) · Athens-Clarke County Code § 5-1-3
Corpus is an independent public-information project, not the official City of Athens-Clarke County website. Stable reference: corpuslaw.us/code/2490b3f3-fa7f-4287-9400-9d5e21e9246b
Sec. 5-1-3. - Pretreatment of wastewater.
(a) Pretreatment facilities. Users shall provide necessary wastewater treatment as required to comply with this chapter and shall achieve compliance with all categorical pretreatment standards, local limits and the prohibitions set out by the public utilities director, whichever is more stringent. Any facilities required to pretreat wastewater to a level acceptable to Athens-Clarke County shall be provided, operated, and maintained at the user's expense. Detailed plans showing the pretreatment facilities and operating procedures shall be submitted to Athens-Clarke County for review, and shall be acceptable to Athens-Clarke County before construction of the facility. The review of such plans and operating procedures will in no way relieve the user from the responsibility of modifying the facility as necessary to produce an acceptable discharge to the POTW under the provisions of this chapter. (b) Additional pretreatment measures: (1) Meat packing plant requirements. No meat packing or allied products plants shall discharge waste or water into the POTW unless the following conditions are met: a. There shall be a separation of domestic wastewater from the bathrooms and the packing wastewater. The domestic wastewater from all bathrooms may be emptied directly into the POTW. If there are floor drains in the bathroom area, these drains must be so arranged that no byproducts of production can be emptied directly or indirectly into them. b. All meat packing wastewater, before entering the POTW, must pass through a 30 divisions per inch by 20 divisions per inch mesh vibrating screen or a device that will provide a complete separation of feathers, hair, offal and other packing byproducts. All floor drains or outside drains in pits shall be so connected that they will go through this screening process and no traps left available where covers may be raised and feathers, hair, offal and other packing byproducts emptied to go into the POTW without first going through these screens. c. All plants shall furnish at their expense a layout showing the arrangement of their wastewater piping or troughs to be approved by Athens-Clarke County. d. If sufficient fall is not available at the packing plants for effective screening, then a system of pumping of the wastewater to provide the screening must be provided at the owner's expense to adequately accomplish the screening. e. All meat processors not covered under this meat packing section will be subject to the provisions of section 5-1-2(i). (2) Control of discharge. As a result of upset to the POTW (existing or potential), the public utilities director may require a user to restrict its discharge during peak flow periods, designate that certain wastewater be discharged only into specific sewers, relocate and/or consolidate points of discharge, separate sewage wastestreams from process wastestreams, and such other conditions as may be necessary to protect the POTW and determine the user's compliance with the requirements of this chapter. (3) Sand interceptors. Sand interceptors shall be provided when, in the opinion of the public utilities director, they are necessary for the proper handling of wastewater containing excessive amounts of sand; except that such interceptors shall not be required for residential users. All sand interception units shall be of type and capacity approved by the public utilities director and shall be so located to be easily accessible for cleaning and inspection. Such interceptors shall be inspected, cleaned, and repaired regularly, as needed, by the owner at his expense. (4) Flammable substances. Users with the potential to discharge flammable substances may be required to install and maintain an approved combustible gas detection meter. (c) Accidental discharge/slug control plans. The public utilities director may require any user to develop and implement an accidental discharge/slug control plan. At least once every two years the public utilities director shall evaluate whether each significant user needs such a plan. Any user required to develop and implement an accidental discharge/control slug plan shall submit a plan which addresses, at a minimum, the following: (1) Description of discharge practices, including non-routine batch discharges. (2) Description of stored chemicals. (3) Procedures for immediately notifying the POTW of any accidental or slug discharge. Such notification must also be given for any discharge which would violate any of the prohibited discharges in section 5-1-2 (c) of this chapter. (4) Procedures to prevent adverse impact from any accidental or slug discharge. Such procedures include, but are not limited to, inspection and maintenance of storage areas, handling and transfer of materials, loading and unloading operations, control of plant site run-off, worker training, building of containment structures or equipment, measures for containing toxic organic pollutants (including solvents), and/or measures and equipment for emergency response. (d) Tenant responsibility. Where an owner of property leases premises to any other person as a tenant under any rental or lease agreement, if either the owner or the tenant is an user, either or both may be held responsible for compliance with the provisions of this chapter. (e) Hauled wastewater: (1) Septic tank waste may be accepted into the POTW at a designated receiving structure within the treatment plant area, and at such times as are established by the public utilities director, provided such wastes do not cause the WRF to violate its permit, fail a toxicity test, or cause interference or pass through. Wastewater discharge permits for individual vehicles to use such facilities shall be issued by the public utilities director. (2) The discharge of hauled industrial wastes requires prior approval and a wastewater discharge permit from Athens-Clarke County. Only wastes generated within Athens-Clarke County will be accepted. The public utilities director shall have authority to prohibit the disposal of such waste if such disposal would interfere with the treatment plant operation. Waste haulers are subject to all other sections of this chapter. A manifest system will be utilized for each truckload of industrial waste to document where the industrial waste was generated. (3) Any person, firm or corporation desiring to discharge or empty any septic tank or portable toilet contents shall be certified in accordance with Rules and Regulations for Individual Sewage Disposal System, chapter 270-5-25, Georgia Department of Human Resources and the Clarke County Board of Health. (4) Septage and portable toilets: No person, firm or corporation shall discharge or empty any matter or contents of a septic tank and portable toilets into the wastewater system of Athens-Clarke County without paying the charge as established by resolution of the Mayor and Commission and discharging the same at the point hereinafter indicated. The public utilities director shall have the authority to limit or prohibit the disposal of wastes generated outside of Athens-Clarke County if such disposal would interfere with the treatment plant operations. The method of payments for utilizing this service shall be based on procedures as approved by the public utilities director. The point of emptying of the same shall be at the Cedar Creek Water Reclamation Facility or as directed by the public utilities director. A manifest system will be utilized for each truckload of septage to document where the septage was generated. (5) Portable toilet waste shall contain only domestic wastewater and those chemicals approved for use in portable toilets. (6) No person, firm or corporation shall discharge or empty any matter or contents of grease, oil or sand interceptors into any part of the wastewater collection and treatment system of Athens-Clarke County. (7) Liquid wastes or byproducts transported over highways or public roads or streets of ACC shall be in watertight and completely covered containers or vehicles. (f) Vandalism. No person shall maliciously, willfully or negligently break, damage, destroy, uncover, deface, tamper with or prevent access to any structure, appurtenance or equipment, or other part of the POTW. Any person found in violation of this requirement shall be subject to the provisions set out in sections 5-1-10 through 5-1-12.
(Ord. of 10-2-2018(1), § 1)
Ask a question about Athens-Clarke County law
Corpus searches the Athens-Clarke County sections it holds and shows the ones that match, with their citations. Free, no sign-in.