§ 7-1-62 — Special rules

Code of the Unified Government of Athens-Clarke County, Georgia (Supp. No. 48, codified through Ordinance of May 5, 2026) · Athens-Clarke County Code § 7-1-62

Corpus is an independent public-information project, not the official City of Athens-Clarke County website. Stable reference: corpuslaw.us/code/8ae05c87-7d1c-4d73-9621-2176b95add4e

Sec. 7-1-62. - Special rules.

The following rules are in addition to and shall take precedence over the National Electrical Code, 1990 Edition: (1) Branch circuits/residential. Branch circuits shall serve only one room and no circuit shall extend into another room except for control purposes, unless approved by the chief building official. (2) Electrical fences. So called "electrical fences," consisting of an electrically charged conductor or other electrically charged devices, intended to enclose, exclude, or restrict persons or animals by electric shock, shall not be installed or used regardless of its source of supply except by special permission granted after written application to the chief building official. (3) Reserved. (4) Wiring method: a. All wires installed for electric lights, heat, or power in or on buildings or structures shall be installed in iron conduits, electric metallic tubing, steel covered cables, nonmetallic tubing, or metal raceways. Nonmetallic wiring may be installed in single family residences, duplexes, apartments, and for temporary purposes. b. Open wiring on insulators shall not be permitted in or on the building except by special permission from the chief building official. c. Concealed knob and tube wiring shall not be permitted.

(Ord. of 1-5-93, § 1; Ord. of 4-3-2001, § 1)

Ask a question about Athens-Clarke County law

Corpus searches the Athens-Clarke County sections it holds and shows the ones that match, with their citations. Free, no sign-in.