§ 7-5-12 — Compliance alternatives
Code of the Unified Government of Athens-Clarke County, Georgia (Supp. No. 48, codified through Ordinance of May 5, 2026) · Athens-Clarke County Code § 7-5-12
Corpus is an independent public-information project, not the official City of Athens-Clarke County website. Stable reference: corpuslaw.us/code/1e6b891a-9c9a-46af-b489-bdc3c217664a
Sec. 7-5-12. - Compliance alternatives.
The following subsections (1) through (5) contain generally acceptable compliance alternatives illustrating principles which shall be applied to the rehabilitation of existing buildings by enforcement authorities in Athens-Clarke County. It is recognized for purposes of this chapter that all building systems interact with each other; therefore, any consideration of compliance alternatives should take into account all existing and proposed conditions to determine their acceptability. The compliance alternatives are not all-inclusive and do not preclude consideration and approval of other alternatives by any enforcement authority. (1) Compliance alternatives for an inadequate number of exits include, but are not limited to, the following: a. Provide connecting fire-exit balconies acceptable to the enforcement authority between buildings; b. Provide alternative exits or egress facilities leading to safety outside the building or to a place of safe refuge in the building or an adjoining building as acceptable to the enforcement authority; c. Provide an exterior fire escape or escapes as acceptable to the enforcement authority where the providing of enclosed interior or enclosed exterior stairs is not practical; or d. Install early fire warning and fire suppression systems. (2) Compliance alternatives for excessive travel distances to an approved exit include, but are not limited to, the following: a. Install an approved smoke detection system throughout the building; b. Install an approved completely automatic fire suppression system; c. Subdivide the exit travel route with smoke-top doors acceptable to the enforcement authority; d. Increase the fire resistance rating of corridor walls and doors; or e. Provide additional approved means of escape. (3) Compliance alternatives for unenclosed or improperly enclosed exit stairways or vertical shafts include, but are not limited to, the following: a. Improve enclosure of exit stairway; b. Add a partial fire suppression system; c. Add a sprinkler draft curtain; or d. Add a smoke detection system. (4) Compliance alternatives for inadequate or a total lack of fire partitions or fire separation walls shall be as set forth in subsection (3) hereinabove. (5) Compliance alternatives for a lack of required protection of openings in exterior walls where a fire exposure is a risk include, but are not limited to, the following: a. Improve fire resistance of existing openings and protect them with fire-related windows or doors as appropriate; b. Seal the openings with fire-related construction as approved by the enforcement authority; or c. Install an approved fire suppression system.
(Ord. of 1-5-93, § 1)
Ask a question about Athens-Clarke County law
Corpus searches the Athens-Clarke County sections it holds and shows the ones that match, with their citations. Free, no sign-in.
