For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 8-2-4 — Development standards

Code of the Unified Government of Athens-Clarke County, Georgia (Supp. No. 48, codified through Ordinance of May 5, 2026) · Athens-Clarke County Code § 8-2-4

Corpus is an independent public-information project, not the official City of Athens-Clarke County website. Stable reference: corpuslaw.us/code/d10d1f26-32c8-4059-81e8-c8ad9c16161c

Sec. 8-2-4. - Development standards.

(a) Residential and nonresidential. (1) All new construction and substantial improvements shall be constructed with materials resistant to flood damage utilizing methods and practices that minimize flood damage and shall be anchored to prevent flotation, collapse or lateral movement of the structure. (2) Electrical, heating, ventilation, plumbing and air conditioning equipment and other service facilities shall be elevated a minimum of one foot above the base flood elevation. (3) All new and replacement water supply systems shall be designed to minimize or eliminate infiltration of floodwaters into the system. (4) New and replacement sanitary sewage systems shall be designed to minimize or eliminate infiltration of floodwaters into the systems and discharges from the systems into floodwaters. (5) On-site waste disposal systems shall be located to avoid impairment to them or contamination from them during flooding. (6) Any alteration, repair, reconstruction or improvement to a structure on which the start of construction was begun after the effective date of this chapter shall meet the requirements of "new construction" as contained in this chapter. (7) New construction or substantial improvement of any residential structure shall have the lowest floor, including basement, elevated a minimum of two feet above the base flood elevation. (8) New construction or substantial improvement of any commercial, industrial or other nonresidential structure shall either have the lowest floor, including basement, elevated two feet above base flood elevation or, together with attendant utility and sanitary facilities, shall be flood-proofed to one foot above the base flood elevation, with walls substantially impermeable to the passage of water and structural components having the capability of resisting hydrostatic and hydrodynamic loads and the effect of buoyancy. A registered professional engineer or architect shall develop and/or review structural design, specifications and plans for the construction, and shall certify that the design and methods of construction are in accordance with accepted standards of practice for meeting the applicable provisions of this section. A record of such certificates, which includes the specific elevation (in relation to mean sea level) to which such structures are flood-proofed, shall be maintained by the chief building official. (9) For all new construction and substantial improvements, fully enclosed areas below the lowest floor formed by foundation and other exterior walls shall be designed so as to be unfinished or flood resistant enclosure. The enclosure shall be designed to equalize hydrostatic flood forces on exterior walls by allowing for the automatic entry and exit of floodwaters. Designs for complying with this requirement must either be certified by a registered professional engineer or architect or meet or exceed the following minimum criteria: a. A minimum of two openings having a total net area of not less than one square inch for every square foot of enclosed area subject to flooding shall be provided. b. The bottom of all openings shall be no higher than one foot above grade. Openings may be equipped with screens, louvers, valves or other coverings or devices, provided that they permit the automatic entry and exit of floodwaters. c. So as not to violate the "Lowest Floor" criteria of this chapter, the unfinished or flood resistant enclosure shall only be used for parking of vehicles, limited storage of maintenance equipment used in connection with the premises, or entry to the elevated area; and d. the interior portion of such area shall not be partitioned or finished into separate rooms. (10) Any changes or revisions, proposed as part of a new construction or substantial improvement project to the flood data adopted herein and shown on the Flood Insurance Rate Map (FIRM) shall be submitted to FEMA for review as a Conditional Letter of Map Revision (CLOMR) or Conditional Letter of Map Amendment (CLOMA), whichever is applicable. Upon completion of the project the developer is responsible for submitting the as-built data to FEMA in order to obtain the final Letter of Map Revision (LOMR). (b) Manufactured homes. (1) All manufactured homes to be placed or substantially improved within zones A1—30, AH and AE shall be elevated on a permanent foundation such that the lowest floor of the manufactured home is elevated two feet above the base flood elevation and shall be securely anchored to an adequately anchored foundation system in accordance with the provisions of this chapter. (2) All manufactured homes shall be anchored to resist flotation, collapse or lateral movement by providing over-the-top and frame ties to ground anchors. Specific requirements shall be that: a. over-the-top ties be provided at each end of the manufactured home, with one additional tie per side at an intermediate location on manufactured homes of less than 50 feet or two additional ties per side for manufactured homes of 50 feet or more; b. frame ties be provided at each corner of the manufactured home with four additional ties per side at intermediate points for manufactured homes less than 50 feet long and one additional tie for manufactured homes of 50 feet or longer; and c. all components of the anchoring system be capable of carrying a force of 4,725 pounds and any additions to the manufactured home be similarly anchored. (3) For new manufactured home parks and subdivisions; for expansions to existing manufactured home parks and subdivisions; for existing manufactured home parks and subdivisions where the repair, construction, or improvement of the streets, utilities, and pads equals or exceeds 50 percent of value of the streets, utilities and pads before the repair, reconstruction or improvement has commenced; and for manufactured homes not placed in a manufactured home park or subdivision, the following are required: a. Stands or lots are elevated on compacted fill or on pilings so that the lowest floor of the manufactured home will be at least two feet above the base flood level; b. Adequate surface drainage and access for a hauler are provided; and c. In the instance of elevation on pilings: 1. Lots are large enough to permit access steps; and 2. Piling foundations are placed in stable soil no more than ten feet apart; and 3. Reinforcement is provided for pilings more than six feet above the ground level. (c) Standards for recreational vehicles. All recreational vehicles places on sites within Zones A1—30, AH, and AE on the Athens-Clarke County FIRM shall either be on the site for fewer than 180 consecutive days and be fully licensed and ready for highway use, or meet the permit requirements of Section 8-2-3(a) and Section 8-2-4(b). A recreational vehicle is ready for highway use if it is on its wheels or jacking system, is attached to the site only by quick disconnect type utilities and security devices, and has no permanently attached additions. (d) Standards for subdivision proposals and other development proposals. (1) All subdivision and/or other development proposals shall be consistent with the need to minimize flood damage and shall be reasonably safe from flooding; (2) All subdivision and/or other development proposals shall have public utilities and facilities such as sewer, gas, electrical and water systems located and constructed to minimize flood damage; (3) All subdivision and/or other development proposals shall have adequate drainage provided to reduce exposure to flood hazard; and (4) Base flood elevation data shall be provided for subdivision proposals and other proposed development (including manufactured home parks and subdivisions) on proposed projects of five acres or which have 50 or more lots. (e) Standards for critical facilities. (1) Notwithstanding section 8-2-2(b), critical facilities shall not be located in the 100-year floodplain or the 500-year floodplain. (2) All ingress and egress from any critical facility must have minimum elevation equal to or above the 500-year flood elevation. (f) Standards for streams without established base flood elevations and/or floodway. For A-zones located within the areas of Special Flood Hazard, or where streams exist but no base flood data have been provided, or where base flood data have been provided but a Floodway has not been delineated, the following provisions apply: (1) When base flood elevation data or floodway data have not been provided, then the applicant shall provide to the Department of Transportation and Public Works for review any scientific or historic base flood elevation and floodway data available from a federal, state, or other source, in order to administer this chapter. Only if data are not available from these sources, then the following shall apply: a. No encroachment, including structures or fill material, shall be located within area equal to the width of the stream or 75 feet, whichever is greater, measured from the top of stream bank, unless certification by a registered professional engineer is provided demonstrating that the encroachment shall not result in more than a one-foot increase in flood levels during the occurrence of a base flood discharge. b. In Areas of Special Flood Hazard without base flood elevation data, new construction and substantial improvements of existing structures shall have the lowest floor of the lowest enclosed area (including basement) elevated no less than three feet above the highest adjacent grade at the building site. Openings sufficient to facilitate the unimpeded movements of floodwaters shall be provided in accordance with the standards identified in section 8-2-4. (g) Standards for Areas of Shallow Flooding (AO or AH Zones). For Areas of Special Flood Hazard designated "AO" or "AH" on the community's Flood Insurance Rate Map, the following provisions apply: (1) All new construction and substantial improvements of residential structures shall have the lowest floor, including basement, elevated to the flood depth specified on the Flood Insurance Rate Map (FIRM), above the highest adjacent grade. If no flood depth number is specified, the lowest floor, including basement, shall be elevated at least three feet above the highest adjacent grade. Openings sufficient to facilitate the unimpeded movements of floodwaters shall be provided in accordance with the standard identified in section 8-2-4. (2) New construction or the substantial improvement of a nonresidential structure may be flood-proofed in lieu of elevation. The structure, together with attendant utility and sanitary facilities, must be designed to be water tight to the specified FIRM flood elevation plus a minimum of one foot, above highest adjacent grade, with walls substantially impermeable to the passage of water, and structural components having the capability of resisting hydrostatic and hydrodynamic loads and the effect of buoyancy. A registered professional engineer or architect shall certify that the design and methods of construction are in accordance with the accepted standards of practice for compliance with the provisions above. (3) Drainage paths shall be provided to guide floodwater around and away from any proposed structure.

(Ord. of 12-5-91 § 1(IV); Ord. of 3-3-92 § 1; Ord. of 3-6-2007, § 1; Ord. of 9-6-2022(1), § 1)

Ask a question about Athens-Clarke County law

Corpus searches the Athens-Clarke County sections it holds and shows the ones that match, with their citations. Free, no sign-in.