§ 108 — LIABILITY
Atlanta City Code (Code of Ordinances, Part II) (Supp. No. 108, Update 1: codified through Ordinance No. 2026-37 (26-O-1511), enacted September 30, 2026) · Atlanta Land Development Code, App. F, ch. I, § 108
Corpus is an independent public-information project, not the official City of Atlanta website. Stable reference: corpuslaw.us/code/f399b28e-491b-4785-a3a1-b2796221e976
108— - LIABILITY
This Code shall not be construed as imposing upon the City of Atlanta any liability or responsibility for damages to any person or property caused by any defect in any piping or appliance mentioned herein, or by installation thereof, nor shall the City of Atlanta, or any official or employee thereof, be held as assuming any such liability or responsibility by reason of the inspection authorized hereunder or the certificate of approval issued by the Inspector. SECTION 2: That Chapter 2, Definitions, be altered by adding the following definitions in their proper places. That the definitions on "Combustible Material" be replaced as follows: Combustible Material. As pertaining to materials adjacent to or in contact with heat producing appliances, vent connectors, gas vents, chimneys, steam and hot water pipes, and warm air ducts, shall mean materials made of or surfaced with wood, compressed paper, plant fibers, or other materials that are capable of being ignited and burned. Such material shall be considered combustible even though flame-proofed, fire-retardant treated, or plastered. For the purposes of NFPA 96 - GYPSUM WALLBOARD is considered a combustible material. Director: The Director of the Bureau of Buildings is the administration authority to administer and enforce the provisions of this Code as adopted or amended. SECTION 3: That Chapter 3, Gas Piping Installations, be amended as follows: (a) In Section 305.6, Add new paragraph 305.6.4: "305.6.4 Piping and connectors shall be run full size as required by the tables to a distance of 18 inches maximum upstream from the appliance gas valve inlet connection. A reduction may be made in piping size within 18 inches upstream from the appliance gas connection to the normal size of such gas connection." (b) In Section 308.6, Add new sentences: "Where concealed piping is located in hollow walls or chases or vertical furred spaces the spaces concealing the pipe shall be ventilated to permit the escape of gas should leakage develop. Ventilation may be provided by small grilles in the wall (two: one high, one low, on each floor) or by making the opening through which the pipe leaves the concealed space at least ½″ larger than outside diameter of pipe." (c) In Section 308, Add new Sections 308.8: "308.8. CONNECTIONS IN ORIGINAL INSTALLATIONS: When installing gas piping which is to be concealed, unions, tubing fittings, running threads, right and left couplings, bushings, and swing joints made by combinations of fittings shall not be used." (d) In Section 309, Add new Section 309.5.3: 309.5.3. Inaccessible Piping: For piping installations in an inaccessible ceiling or crawl space, gas piping that conforms with Section 306.1 or 306.2 and having welded or brazed joints, may be installed in such spaces and shall also be tested in accordance with Section 311 utilizing a minimum test pressure of 50 psig." (e) In Section 311.2: Method of Testing, revise Section to read as follows: (1) For threaded piping installation: When using a bourbon type gage with one pound increments, the gas piping shall withstand a pressure of 10 psig for a period of not less than 10 minutes. With a ¼ lb. increment gage, the gas piping shall withstand a pressure of 5 psig for a period of not less than 10 minutes, without showing any drop in pressure on test. (2) For welded piping installation: The test pressure shall not be less than 50 psig, and this pressure shall be held for a period of not less than thirty (30) minutes with no drop in pressure. A bourbon type gage with one pound increments shall be used for testing. SECTION 4: That Chapter 4, Appliances Installation, be modified as follows: (a) In Section 402.1, Add the following Exception: "EXCEPTION: The following procedure is hereby established for acceptance of unlisted heating equipment for industrial applications where such listing by an approved agency is not practical due to equipment size or configuration. The following information shall be submitted to, and accepted by, the Director prior to the ordering and installation of equipment:" 1. A statement that the application of the heating equipment is for industrial use. 2. A notarized Letter of Acceptance from the insurance carrier that the insurance carrier has reviewed the plans and specifications for the unlisted heating equipment and found them to be satisfactory. Where the owner is self-insured, the owner shall submit the same statement. 3. Shop drawing and/or plans for the installation must be sealed by a licensed professional mechanical engineer registered in the State of Georgia. 4. A notarized letter from a professional mechanical engineer registered in the State of Georgia stating that the engineer shall personally supervise the installation and start-up procedure of the unlisted equipment, and all findings and recommendations shall be forwarded to the Gas Official. 5. A statement that the installation shall be reviewed and approved by the Atlanta Gas Light Company where natural gas is utilized as a fuel source. Where other fuel sources are used, similar such approvals shall be required by the appropriate vendor. 6. A statement by the property owner that the insurance carrier will be specifically requested to witness the start-up procedure, where applicable. 7. A statement that a permit shall be obtained from the City of Atlanta HVAC Division before installation is started. Upon satisfactory resolution of the above requirements, a permit may be issued for such installation. All inspections thereafter shall be conducted as usual except that the inspector shall be present to witness the above-mentioned start-up procedure. (b) In Section 402.4.7, Add the following sentence: "Provision for make-up air shall be provided for Type 2 clothes dryers, with a minimum free area of one square inch for each 1,000 BTU per hour total input rating of the dryer(s) installed." SECTION 5: That Chapter 5, Installation Requirements for Specific Appliances, be modified as follows: (a) In Section 502, Add new Section 502.4: "502.4 Vertical Clearance Above Cooking Top. Household cooking appliances shall have a vertical clearance above the cooking top of not less than 30 inches to combustible material or metal cabinet, except the clearance may be reduced to not less than as 24 inches as follows: 1. The underside of the combustible material or metal cabinet above the cooking top is protected with not less than ¼ inch insulating millboard covered with sheet metal not less than 0.0122 inch thick, or 2. A metal ventilating hood of sheet metal not less than 0.0122 inch thick is installed above the cooking top with a clearance of not less than ¼ inch between the hood and the underside of the combustible material or metal cabinet, and the hood is at least as weide as the appliance is and is centered over the appliance." (b) In Section 506, Add new Section 506.1.4: "506.1.4 A decorative gas appliance for installation in a fire place shall be installed only in a vented fireplace having a working flue and constructed of noncombustible materials. These appliances may not be thermostatically controlled. The fireplace chimney shall have a permanent vent opening of not less than the area specified on the appliance table. (c) In Section 507.12, Add the following sentence: "See Georgia State Energy Code for Buildings." (d) In Section 510.4, Add the following paragraph: "4. Two adjoining sides of the floor furnace shall be at least 15″ from walls to eliminate necessity of occupants walking over hot register." (e) In Section 516, Add new Section 516.3: 516.3 COMBUSTION AND VENTILATION AIR: "1. Where unvented infrared heaters are used, natural or mechanical means shall be provided to supply and exhaust at least 4 cfm per 1000 BTU per hour input of installed heaters. 2. Exhaust openings for removing flue products shall be above the level of the heaters." (f) In Section 517.1.3, Add the following sentence: "Exhaust ducts serving Type 2 clothes dryers shall be constructed of a material equivalent in strength and corrosion resistance to min. 24 U.S. standard gage or min. 26 manufactured gage galvanized steel." (g) Add new Section 529; entitled Fireplace Log Lighters 529—FIREPLACE LOG LIGHTERS 529.1—GENERAL CONSTRUCTION: "The General construction of log lighters shall be in accordance with reasonable concepts of safety, substantiality and durability. They shall be designed to maintain a fixed relationship between essential parts under normal conditions of handling and usage." 529.2—BURNER PARTS: "Burner parts shall be accessible for cleaning after installation of lighter." 529.3—LIGHT (BURNER HEAD): "1. Burner parts shall be level with or above hearth. "2. The burner shall be provided with an orifice which shall limit maximum burner input to 50,000 BTU per hour. "3. Installations shall be made in accordance with manufacturer's instructions." 529.4—PIPING: "Steel pipe and fittings only shall be encased within the hearth." 529.5—MANUAL SHUT-OFF VALVE: "A manual shut-off valve shall be installed in a manner to provide safe and convenient lighting of the gas. The valve after installation shall be accessible for service and lubrication when required." SECTION 6: That Chapter 6, Venting of Appliances, be modified as follows: (a) In Section 604.5, Add the following sentences: "A draft hood shall be located so its relief opening is not less than six inches from any surface except that of the gas utilization equipment it serves and the venting system to which the draft hood is connected. When a greater or lesser clearance is indicated on the equipment label, the clearance shall not be less than that specified on the label. These clearances shall not be reduced." (b) In Section 605.4.1, Add the following sentence and table: Single wall metal vents not more than 6 inches in diameter shall be of galvanized steel of not less than No. 28 Galvanized Sheet Gauge. For pipes larger than 6 inches in diameter the following table shall apply: Diameter | Gauge More than 6 inches to 10 inches | No. 26 More than 10 inches to 15 inches | No. 24 More than 15 inches to 20 inches | No. 22 More than 20 inches to 27 inches | No. 20 (c) In Section 607, Delete 607.1, 607.1.1., 607.1.2., 607.1.3, 607.1.4 in their entirety. Add new Sections: 607.1, 607.1.1, 607.1.2, 607.1.3: 607.1 Materials: 607.1.1 A vent connector shall be made of noncombustible corrosion-resistant material capable of withstanding the vent gas temperature produced by the gas utilization equipment and of sufficient thickness to withstand physical damage. (a) Vent connectors for residential-type appliances shall comply with the following: 1. Appliances Installed in Attics: Vent connectors for listed gas appliances having draft hoods and appliances listed for use with Type B gas vents, which are installed in attics, shall be of Type B or Type L vent material. 2. Appliances Not Installed in Attics: Vent connectors for listed gas appliances having draft hoods and for appliances having draft hoods and equipped with listed conversion burners, which are not installed in attics, shall be of Type B or Type L vent materials or metal pipe having resistance to heat and corrosion not less than that of galvanized sheet steel or aluminum not less than 0.0122 inch thick.* *This corresponds to No. 28 Galvanized Sheet Gage number with all applicable minus tolerances included. Vent connectors for combination gas- and oil-burning appliances, residential incinerators, and appliances other than those noted in "1" above, and which are not installed in attics, shall be of Type L vent material, factory-built chimney section, or steel pipe having resistance to heat and corrosion not less than that of galvanized steel as specified in Table X. 607.1.2 A vent connector for low-heat equipment shall be a factory-built chimney section or steel pipe having resistance to heat and corrosion equivalent to that for the appropriate galvanized pipe as specified in Table X. Factory-built chimney sections shall be joined together in accordance with the chimney manufacturer's instructions. 607.1.3 Vent connectors for medium-heat equipment and commercial and industrial incinerators shall be constructed of factory-built medium-heat chimney sections or steel of a thickness not less than that specified in Table XI, and shall comply with the following: 1. A steel vent connector for equipment with a vent gas temperature in excess of 1000 F, measured at the entrance to the connector, shall be lined with medium duty fire brick (ASTM C64, Type F), or the equivalent. 2. The lining shall be at least 2-½ inches thick for a vent connector having a diameter or greatest cross-section dimension of 18 inches or less. 3. The lining shall be at least 4-½ inches thick laid on the 4-½-inch bed for a vent connector having a diameter or greatest cross-section dimension greater than 18 inches. Table X Minimum Thickness for Galvanized Steel Vent Connectors for Low-Heat Appliances Diameter of Connector, Inches | Minimum Thickness, Inches* less than 6 | 0.019 (26) 6 to less than 10 | 0.023 (24) 10 to 12 inclusive | 0.029 (22) 14 to 16 inclusive | 0.034 (20) over | 0.056 (16) *The figures in parentheses are the corresponding Galvanized Sheet Gage number with all applicable minus tolerances included. Table XI Minimum Thickness for Steel Vent Connectors for Medium Heat Equipment and Commercial and Industrial Incinerators Vent Connector Size Diameter, Inches | Area Square Inches | Minimum Thickness, Inches* up to 14 | up to 154 | 0.053 (16) over 14 to 16 | 154 to 201 | 0.067 (14) over 16 to 18 | 201 to 254 | 0.093 (12) over 18 | Larger than 254 | 0.123 (10) *The figures in parentheses are the corresponding Manufacturer's Standard Gage number with all applicable minus tolerances included. 4. Factory-built chimney sections, if employed, shall be joined together in accordance with the chimney manufacturer's instructions. (d) In Section 607.13, Add the following EXCEPTION: "EXCEPTION: Vent connectors shall not connect to any chimney that is in use for equipment burning other fuel unless such chimneys are of adequate area and height to produce the necessary draft at all times and assure safe and satisfactory operation of all equipment." SECTION 7: That Chapter 8, Gas Equipment in Unlisted Boilers, be modified as follows: (a) In Section 801, SCOPE, add the following: "Certification requirements, repairs, installations, and alterations shall be in accordance with the Official Code of Georgia Annotated Title 34 Chapter 11 (Boiler and Pressure Vessel Safety Act). All boilers must be permitted and inspected by the State of Georgia, Department of Labor, Safety Engineering Section." SECTION 8: That a new section be added to the Appendix. APPENDIX E: GENERAL PRECAUTIONS FOR SAFETY 1. TURN GAS OFF All gas piping or gas appliance installation shall be performed with the gas turned off to eliminate hazards from leakage of gas. 2. NOTIFICATION OF INTERRUPTED SERVICE Except in an emergency, it shall be the duty of the installing agency when the gas supply is to be turned off, to notify all affected consumers. 3. BEFORE TURNING GAS OFF When two or more consumers are served from the same supply, precaution shall be exercised to assure that only service to the proper consumer is turned off. 4. CHECKING FOR GAS LEAKS Matches, candles, flame or other sources of ignition shall not be employed to check for gas leakage. 5. USE OF LIGHTS Artificial illumination used in connection with a search for gas leakage shall be restricted to electric hand flash lights, electric lights controlled only by switches remote from the area of the leakage, or approved safety lamps. 6. NO SMOKING When working on piping which contains or has contained gas, smoking shall not be permitted. 7. HANDLING FLAMMABLE LIQUIDS Flammable liquids used by the installer shall be handled with proper precautions and shall not be left within the premises from the end of one working day to the beginning of the next. 8. WORK INTERRUPTIONS When interruptions in work occur, the system shall be left in a safe and satisfactory condition. SECTION 9: VALIDITY If any section, sub-section, sentence, clause or phrase of this ordinance is, for any reason held to be unconstitutional (or invalid) such (holding) shall not affect the validity of the remaining portion of this ordinance. SECTION 10: This ordinance shall become effective upon the approval by the Mayor or upon becoming law without approval, except as to cases pending in any court, the previous Gas Pipe Code of the City of Atlanta, Georgia, shall remain in full force and in effect until those cases are finally determined. SECTION 11: All ordinances and parts of ordinances in conflict with this ordinance are hereby repealed. Safety Engineering Section."
Ask a question about Atlanta law
Corpus searches the Atlanta sections it holds and shows the ones that match, with their citations. Free, no sign-in.
