For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 16-18B.011 — Dumpsters, loading areas and entrances, mechanical and accessory features, and fences and walls

Atlanta City Code (Code of Ordinances, Part II) (Supp. No. 108, Update 1: codified through Ordinance No. 2026-37 (26-O-1511), enacted September 30, 2026) · Atlanta Land Development Code § 16-18B.011

Corpus is an independent public-information project, not the official City of Atlanta website. Stable reference: corpuslaw.us/code/2c871b16-fbfb-443c-a6db-f67410c7ccac

Sec. 16-18B.011. - Dumpsters, loading areas and entrances, mechanical and accessory features, and fences and walls.

(1) Dumpsters and loading docks shall be located in the side or rear yard, shall be screened from public view with opaque walls or fences a minimum of six (6) feet in height, and shall be paved with impervious materials. (2) Where provided, all loading spaces shall provide vertical clearance of fourteen (14) feet and shall not be located within the required sidewalk. (3) Building mechanical and accessory features: a. Shall be located to the side or rear of the principal structure and shall not be visible from the public view. Screening with plant or fence materials shall be required if the equipment is otherwise visible from the public view. b. When located on rooftops, shall be incorporated in the design of the building and screened with building materials similar to the building. c. Shall not be permitted between the building and any public street. (4) Barbed wire, razor wire, and chain link fencing shall be prohibited (5) Loading requirements: Minimum off-street spaces shall be provided according to Table 6: SPI-2 Fort McPherson District Loading Table. All loading spaces shall provide vertical clearance of 14 feet and shall not be located within the required sidewalk. See section 16-18B.014(1) for screening requirements. Reduction of loading spaces may be approved by the director of the Office of Zoning and Development subject to a shared loading arrangement that avoids conflicting loading demands. Table 6: SPI-2 Fort McPherson Loading Table Unit of Measure | Required Loading | Spaces 12' x 35' | 12' x 55' Residential Dwellings/Lodgings | Less than 20 units | None | None 20 to 50 units | 1 | None 51 to 200 units | 2 | None 201 units and above | 3 | None All Other Uses | Up to 10,000 sq. ft. floor area | None | None 10,001 sq. ft. to 40,000 sq. ft. floor area | 1 | None 40,001 sq. ft. to 100,000 sq. ft. floor area | 2 | None 100,001 sq. ft. to 250,000 sq. ft. floor area | 2 | 1 250,001 sq. ft. to 500,000 sq. ft. floor area | 2 | 2 500,001 sq. ft. floor area and above | 2 | 3

(Ord. No. 2019-19(18-O-1326), § 1, 3-13-19)