§ 16-18D.013 — Relationship of building to street
Atlanta City Code (Code of Ordinances, Part II) (Supp. No. 108, Update 1: codified through Ordinance No. 2026-37 (26-O-1511), enacted September 30, 2026) · Atlanta Land Development Code § 16-18D.013
Corpus is an independent public-information project, not the official City of Atlanta website. Stable reference: corpuslaw.us/code/b2785159-c1df-4852-89ca-1413dbdc3e21
Sec. 16-18D.013. - Relationship of building to street.
(1) Delineation of building floors at the third story above sidewalk level and lower shall be articulated through windows, belt courses, cornice lines or similar architectural detailing. (2) Massing and articulation: Building shall include variety in facade treatment, materials, textures, colors and/or window and door patterns and provide a depth change at a minimum of two feet to provide visual interest for every ten feet of wall area. (3) Roofs: All detached single family residential buildings shall have a gable, pitched, or hipped roof minimum roof pitch of 4/12. Flat roofs for detached single family residential buildings are not permitted. Multi-family and mixed-use buildings with flat roofs shall be designed with a three-foot minimum height parapet. (4) The primary pedestrian entrance for access to all sidewalk level uses and business establishments with public or private street frontage a. Shall face and be visible from the public street when located adjacent to such street. When located adjacent to a street that functions as an arterial street or a collector street, said entrance shall face and be visible from such street. b. ?Shall have a visible and accessible push button activator seen from the clear zone sidewalk connected with a minimum five foot wide pedestrian walkway, except for those entrances that are used solely for access to an individual dwelling unit. This provision shall not apply to single-family and two-family residential structures. (5) A street address number shall be located directly above the primary building entrance, shall be clearly visible from the sidewalk and shall be a minimum of six inches in height. (6) Fenestration: a. Street-fronting non-residential uses, with the exception of churches and fire stations, along streets that function as arterial streets and collector streets shall meet the following sidewalk level requirements: i. The length of the facade without intervening fenestration or entryway shall not exceed 20 feet. ii. Fenestration shall not utilize painted glass, reflective glass or other similarly treated or opaque windows. Entrances may be counted towards fenestration requirements. iii. Fenestration shall be provided for a minimum of 65 percent of the length of all street frontages: 1. Beginning at a point not more than three feet above or below the sidewalk, or 2. Beginning at the finished floor elevation to a height no less than ten feet above the finished floor elevation when the finished floor elevation is three feet or less above the sidewalk; or 3. Beginning at a point not more than sidewalk level, to a height no less than ten feet above the finished floor elevation, when the finished floor elevation is below the sidewalk. b. Thirty percent fenestration shall be provided for the length of the sidewalk level frontage for residential uses on all streets, and for non-residential uses except for churches and fire stations, on all streets other than streets that function as arterial streets and collector streets. i. For single family residential uses any façades that face a public or private street shall consist of fenestration that shall be no less than 15 percent and no greater than 40 percent of the total surface wall area. Façades that do not face a public or private street shall consist of fenestration that shall be no less than ten percent of the total surface wall area. Windows may be individual or grouped. No individual window unit shall exceed 28 square feet. Within each individual window unit, no individual window sash, either fixed or operable, shall exceed 16 square feet. ii. Windows shall be double-hung. iii. Each double-hung window shall be surrounded by wood trim between four and six inches wide and shall include a bottom sill. Windows grouped together shall have center mullions two inches wider than the side trim. c. Height of windowsills on the public or private street fronting façade shall be no less than two and one-half feet and no more than three and one-half feet above finished floor elevation. Windows on said façade shall have a minimum height of three feet. d. All windows shall include windowpanes recessed a minimum of two inches from the adjacent façade, unless the façade is constructed as a glass curtain wall. e. Flat "snap-in" muntins and muntins sandwiched between layers of glass are prohibited. (7) Buildings with residential uses at the sidewalk level, or park level shall meet the following regulations: a. All primary pedestrian entrances not adjacent to a public sidewalk shall be linked to the public sidewalk with a pedestrian walkway a minimum of five feet wide. b. All such buildings with more than four residential units that are adjacent to the sidewalk shall have individual entrances to such units directly accessible from the sidewalk and shall open directly onto the adjacent sidewalk, park, trail, plaza, terrace or porch adjacent to the sidewalk. All pedestrian walkways providing such access shall be perpendicular to the street, unless topography prohibits, and shall be permitted to share said walkway with one adjacent unit. c. Such buildings shall have windows at sidewalk-level or park/trail level on each street frontage which are substantially similar in size to the sidewalk level front facade windows. (8) Siding and foundation: a. A building's main/street facing facade should have a minimum of two different cladding materials, excluding the fenestration material. b. Single family and two-family: All exterior facades shall be brick, wood, or Hardiplank, (cementitious siding). Hardiplank siding shall be a maximum of six inches in width. c. Multi-family, Mixed Use, and non-residential: i. All exterior facades adjacent to a public street, public park, and/or trail shall be brick, Hardiplank (cementitious siding) stone, cast stone, architectural metal panels, or true stucco. d. All exterior facades not adjacent to a public street shall be brick, stone, cast stone, true stucco, concrete masonry units, split-faced concrete, or split-faced block. e. Single-family and two-family: foundations shall be finished with brick, smooth stucco, or smooth finish concrete at least two feet above grade. (9) Front porches. a. Front porches and/or stoops on the façade of the principal structure shall be required when such treatments are established by a majority of the single-family detached dwellings on the block face. b. Front porches, when required, shall: i. Be a minimum of 12-feet wide or one-third the width of the front façade, whichever is greater, and a minimum of eight feet deep; and ii. Contain roofs, a minimum of six-inch wide porch roof supports, and steps. c. For parcels with more than one street frontage, the front porch requirements of this section shall only be required to be applied to the building façade located in the front yard of the parcel, and not the half-depth front yard, side yard, or rear yard. (10) Garages. Garages with front-facing garage doors shall be recessed and located a minimum distance of ten linear feet behind the front façade of the principal structure. For parcels with more than one street frontage, front-facing garage doors shall be defined as those facing the front yard of the parcel, and not the half-depth front yard, side yard, or rear yard. (11) Front doors. Front doors shall face and be visible from the adjacent street.
(Ord. No. 2021-53(21-O-0457), § 2(Att. A), 11-10-21)
Ask a question about Atlanta law
Corpus searches the Atlanta sections it holds and shows the ones that match, with their citations. Free, no sign-in.