For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 16-18Q.014 — Relationship of building to street

Atlanta City Code (Code of Ordinances, Part II) (Supp. No. 108, Update 1: codified through Ordinance No. 2026-37 (26-O-1511), enacted September 30, 2026) · Atlanta Land Development Code § 16-18Q.014

Corpus is an independent public-information project, not the official City of Atlanta website. Stable reference: corpuslaw.us/code/5f71a961-d3f4-415d-8c47-15f2e66999cc

Sec. 16-18Q.014. - Relationship of building to street.

1. For purposes of this chapter, sidewalk level shall be defined as any floor of a building with a finished-floor elevation less than or equal to five feet above and below the adjacent sidewalk (or street if no sidewalk is existing). 2. Building floors shall be delineated from the third story above sidewalk level down to each sidewalk level and shall be executed through windows, belt courses, cornice lines and/or similar architectural detailing. 3. General sidewalk level building façade requirements: a. Active uses along all streets shall be provided as indicated in Table 1: SPI-17 Table of Uses in Section 16-18Q.005, to a minimum depth of 40 feet for non-residential uses and 20 feet for residential uses beginning at any sidewalk level street facing building façade except when topographical conditions prevent such treatment. These active uses shall be internally illuminated and serviced by plumbing, heating, and electricity and are limited to uses set forth in Table 1: SPI-17 Table of Uses, with the following exceptions which also shall be allowed: i. Fire command and transformer (or similar electrical) rooms, each not exceeding 10 feet of street fronting façade length; and ii. Structures required for public transit. b. The primary street fronting pedestrian entrance for sidewalk level uses: i. Shall face, be visible and accessible from the clear zone sidewalk with a minimum of five feet wide pedestrian walkway; and ii. Shall have a minimum six inch high street address located directly near the primary building entrance clearly visible from the sidewalk. iii. Shall have a visible and accessible push button activator seen from the clear zone sidewalk connected with a minimum five foot wide pedestrian walkway, except for those entrances that are used solely for access to an individual dwelling unit. This provision shall not apply to single-family and two-family residential structures. c. Residential uses which do not have street frontage shall be linked to the public sidewalk with a minimum four feet wide pedestrian walkway. 4. Fenestration requirements: Street-fronting sidewalk level building façades, except churches/ religious institutions, fire stations & MARTA uses, shall meet the following requirements: a. Length: Fenestration and entrances shall be provided for a minimum of the horizontal length of each street-fronting sidewalk-level façade, as designated in the Table 5: SPI-17 Street Activation Table. The length of façade without intervening fenestration or entryways shall not exceed 20 feet. b. Surface treatment and visibility: Windows and door glass shall utilize clear glass or tinted glass. Tinted glass shall have a transmittance factor of 50 percent or greater and shall have a visible light reflectance factor of ten or less having visibility into the building for a minimum depth of ten feet as measured from the interior windowpane. Painted glass, reflective glass or other similarly treated or opaque windows are prohibited. c. Residential uses: Fenestration and entrances shall have windows at a minimum of four feet in height. d. Non-residential uses: Fenestration and entrances shall be measured beginning at a point not more than 36 inches above the required sidewalk to a height at least ten feet above the sidewalk unless: i. When the finished floor elevation is 36 or more inches above the sidewalk: Beginning at finished floor elevation to at least ten feet above the finished floor elevation; or ii. When the finished floor elevation is below the sidewalk: Beginning at a point not higher than six inches above the adjacent sidewalk to at least ten feet above the finished floor elevation. Table 5: SPI-17 Street Activation Table Use (as further regulated in Table 1: SPI-17 Table of Uses) | Min. Fenestration (as % of street level façade) Outdoor Facilities including: Farmer's Markets, Market Gardens, Urban Gardens Outdoor amusement enterprises, entertainment, music venues, meetings or sales areas. | None - Not Applicable Residential dwellings Bed & Breakfast Inn Childcare Centers Churches/Religious Facilities Clubs/Lodges Hotel & Motel Lodging Nursing Homes/ Personal Care Homes / Assisted Living Facilities/ Rehabilitation Centers Supportive Housing Veterinary | 30% All other uses (allowed in Table 1 in Section 16-18Q.005 but not listed above): | 65%

(Ord. No. 2022-08(22-O-1060), § 1(Exh. A), 4-27-22; Ord. No. 2026-05(26-O-1001), § 9, 2-25-26)

Ask a question about Atlanta law

Corpus searches the Atlanta sections it holds and shows the ones that match, with their citations. Free, no sign-in.