§ 16-20U.007 — Alterations and additions to existing historic/contributing buildings
Atlanta City Code (Code of Ordinances, Part II) (Supp. No. 108, Update 1: codified through Ordinance No. 2026-37 (26-O-1511), enacted September 30, 2026) · Atlanta Land Development Code § 16-20U.007
Corpus is an independent public-information project, not the official City of Atlanta website. Stable reference: corpuslaw.us/code/c931fbe0-20ef-4e54-97d8-8d6c5a2e1415
Sec. 16-20U.007. - Alterations and additions to existing historic/contributing buildings.
The following regulations shall apply to alterations and additions to existing Historic/Contributing buildings. (1) Alterations: a. Windows and doors: i. Replacement windows and doors shall match the size, light pattern, and function of the original historic windows or doors. If the original or historic windows and doors are not present or the design is not known, replacement windows and doors shall be a design consistent with the architectural style and age of the building. ii. All replacement windows with light divisions shall have true divided lights or simulated divided lights. Exterior light divisions must be permanently affixed to the exterior of the glass. iii. If replacement of two or fewer non-historic windows is required due to a material defect or unintentional damage, that existing non-historic window(s) may be also replaced with window(s) that match the existing non-historic window(s) in all characteristics. iv. The replacement and reconfiguration of windows on the side elevations to accommodate kitchens and bathrooms is permitted. v. Dropped ceilings, when located below the head of a window, shall be sufficiently recessed from the window opening to maintain the original exterior appearance. vi. New or replacement doors shall be wood panel or fixed glass in a wood panel, subject to the compatibility rule and shall be consistent with the architectural style of the building. vii. Skylights are permitted on roof slopes not visible from a District right-of-way whenever possible. Protruding bubble skylights are not permitted. b. Siding and façade materials: Replacement siding and façade materials shall be compatible with the original or historic materials. If the original or historic siding and façade materials are not present, the replacement siding and façade materials shall be consistent with the existing architectural style of the building or what was removed. c. Ornamentation: Installation of architectural ornaments, such as brackets, decorative trim, corner boards, bottom boards, fascia boards, porch railing, columns, steps, doors, half-timbering, and attic vents, where none previously existed shall be permitted and shall meet the compatibility rule. d. Original or historic architectural elements, including chimneys, shall be retained. e. Original or historic awnings or canopies shall be retained, and new awnings or canopies may be installed if they are consistent with the architectural style of the building. f. Painting of unpainted masonry surfaces: The painting of unpainted masonry surfaces shall be permitted via the use of a paint product specified for use on exterior masonry surfaces. The color of the paint used shall not be regulated. Except for allowed painting, original or historic masonry surfaces shall not be covered or coated in any other way. g. Original or Historic Front or Side Porches: Existing porches shall be retained and may be enclosed with screen wire or glass provided that the original or historic features of the porch, including balustrades, rails, headers, and columns, are retained and not obscured by the enclosure material. h. Non-Original or Non-Historic Front or Side Porches: Porches may be repaired, replaced, or otherwise maintained to retain their previously existing appearance and components. i. Side porches: Shall be permitted and shall be consistent with the architectural style of the building with setbacks that meet the compatibility rule. j. Decks: Shall be permitted on the rear façade of the principal building and shall not project past the side facades of the principal structure. k. All other alterations shall be consistent with the architectural style of the building and shall meet the compatibility rule. (2) Dormer and gable additions: a. Where visible from a District right-of-way, shall be consistent with the architectural style of the building; b. Where visible from a District right-of-way, roof form, windows, doors, and architectural elements, and ornamentation shall be consistent with the architectural style of the building; c. The existing eave lines of the building shall be retained; d. As measured at the dormer or gable addition, the resulting overall height of the building shall meet the compatibility rule on Bonaventure Avenue and shall not exceed 30 feet on Somerset Terrace; and e. Side yard and rear yard setbacks shall be no closer than the respective setbacks of the existing building. (3) Rear additions: a. Shall be no higher than the existing ridgeline; b. Side yard setbacks shall be no closer than the respective setback of the existing building; c. Rear yard setbacks shall match the underlying zoning; and d. If visible from a District right-of-way, building materials, architectural elements, and ornamentation shall be internally consistent with the architectural style of the addition. (4) Roof plane extensions: a. On properties with a side gabled principal roof, the front roof plane may be extended if the existing roof form and pitch is maintained; b. Where visible from a District right-of-way, windows, doors, and architectural elements, and ornamentation shall be consistent with the architectural style of the building; c. The existing eave lines of the building shall be retained; d. As measured at the roof plane extension, the resulting overall height of the building shall meet the compatibility rule on Bonaventure Avenue and shall not exceed 30 feet on Somerset Terrace; and e. Side yard and rear yard setbacks shall be no closer than the respective setbacks of the existing building. (5) Second story additions: a. Shall be secondary in design to the existing building; b. Shall be set back a minimum of 1/4 the depth of the building measured from the frontmost wall of the building (excluding any front porch, open or enclosed), or 10 feet measured from the front-most wall of the building (excluding any front porch, open or enclosed), whichever is less. c. Shall contain a plate height (distance from subfloor to the top of the framed wall) that does not exceed the plate height of the story beneath the proposed addition; d. Where visible from a District right-of-way, windows, doors, architectural elements, and ornamentation shall be consistent with the architectural style of the building; e. The existing eave lines of the building shall be retained; f. The roof form and pitch shall match the form of both the principal roof and any secondary gables on the front facade; g. Side yard and rear yard setbacks shall be no closer than the respective setbacks of the existing building; and h. As measured at the second story addition, the resulting overall height of the building shall meet the compatibility rule on Bonaventure Avenue and shall not exceed 30 feet on Somerset Terrace.
(Ord. No. 2019-21(18-O-1701), § 3(Att. C), 3-13-19)
Ask a question about Atlanta law
Corpus searches the Atlanta sections it holds and shows the ones that match, with their citations. Free, no sign-in.