For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 16-28.028 — Parking structures

Atlanta City Code (Code of Ordinances, Part II) (Supp. No. 108, Update 1: codified through Ordinance No. 2026-37 (26-O-1511), enacted September 30, 2026) · Atlanta Land Development Code § 16-28.028

Corpus is an independent public-information project, not the official City of Atlanta website. Stable reference: corpuslaw.us/code/b65b8adf-65f3-4615-b268-bb14bff79282

Sec. 16-28.028. - Parking structures.

(1) All parking structures, or any story thereof, located in whole or in part above finished grade and used either as a principal use or as accessory parking for another use shall meet the following standards unless granted a variance by the board of zoning adjustment, with an exception that the Atlanta Urban Design Commission shall have the authority to vary this section for properties subject to the requirements found in Part 16, Chapter 20. However, parking structures which were constructed or which will be constructed pursuant to a valid building permit properly applied for prior to the effective date of the adoption of this section shall be exempt from this Section. Whenever the following regulations conflict with existing zoning regulations the stricter regulation shall apply: a. Parapet walls: On all levels where parking is provided adjacent to an exterior wall, all façades shall have exterior opaque walls a minimum height of 42 inches above any finished grade and any finished floor. b. Public façades: When a parking structure façade is adjacent to or facing any public park or plaza, public right-of-way, public sidewalk, sidewalk-level outdoor dining area, private street, or BeltLine corridor, such façades shall comply with the following: i. Any such façades from finished grade to the fourth level of the parking structure shall have openings screened to prevent views into the structure except for perpendicular vehicular ingress and egress openings at a maximum width of 30 feet and pedestrian access openings at a maximum width of eight feet. ii. Screening elements shall be designed in a structurally sound manner and have a gap of no more than 18 inches from the frame of the screening element to the wall opening. Alternative decorative elements which provide an equivalent level of screening may be allowed in an accessory parking structure where such elements are employed to match the architectural character of the main building. Mesh or decorative panels, tinted or sandblasted opaque spandrel glass, or similar screening elements shall be used. Where mesh or other materials containing openings is used in conjunction with the screening frame, no individual opening shall exceed four square inches. Chain link fencing and similar screening elements shall be prohibited as an allowable mesh or similar screening element. c. Non-public façades: When a façade is adjacent to or facing any R-1 through R-5, RLC, RG-1, RG-2, MR-1, MR-2, or PD-H districts or existing residential use and is not subject to section 1(b) above, all such façades shall comply with the following: i. Height: The structure shall not exceed 35 feet in height from finished grade to the top of the subject exterior wall structure for a minimum distance of 60 feet from each façade adjacent to such above described district or use with the exception of vertical circulation elements such as elevator shafts or stairwells. The underlying zoning requirements regarding maximum height and transitional height plane shall apply. ii. Façade walls: When built at a zero set back on the property line adjacent to the districts or use as allowed by the underlying zoning requirements regarding minimum yards, said façade(s) shall be entirely enclosed with walls which shall also wrap from any such façade corner at the property line a minimum distance of 20 feet away from such an above described adjacent residential district or use. iii. Landscaping: When not built at a zero set back on the property line adjacent to the districts or use, a continuous minimum ten feet wide landscaped strip between the structure and said property line shall be provided, except for perpendicular vehicular ingress and egress openings at a maximum width of 30 feet and pedestrian access openings at maximum width of eight feet. Said landscape strip shall be planted with evergreen ground cover such as mondo grass, liriope spicata, ivy or evergreen shrubs with evergreen trees spaced a maximum distance of 20 feet on center. Said trees shall be a minimum of two and one-half inches in caliper as measured 36 inches above ground, shall be a minimum of 12 feet in height, and shall have a 40 feet minimum mature height. Notwithstanding the foregoing, all plantings, planting replacement and planting removal shall be approved by the city arborist with any administrative variations from the tree planting requirements granted in accordance with Chapter 158 Vegetation, Article II Tree Protection regulations. d. Lighting shall be designed to reduce light spillage outside the parking structure according to the following criteria: i. Any internal illumination in which light fixtures can be directly visible from the exterior of a parking structure shall either be directed internally upward or shall contain shielded internal light fixtures to prevent such visibility. ii. Rooftop lighting shall be located at an elevation height less than the top of the nearest exterior perimeter rooftop wall; or shall be setback a minimum of 15 feet from the exterior perimeter of the rooftop wall at a maximum mounted height of 12 feet above finished floor with cutoff light fixtures that have a maximum 90 degree illumination.

(Ord. No. 2008-67(08-O-0196), § 1, 7-21-08)

Ask a question about Atlanta law

Corpus searches the Atlanta sections it holds and shows the ones that match, with their citations. Free, no sign-in.